INSTALLATION INSTRUCTIONS

95-6731-6

T87F Universal Thermostat

APPLICATION

The T87F Universal Thermostat provides temperature 
control for 24 to 30 Vac residential heating, cooling or 
heating/cooling systems. For heating systems, the T87F 
mounts on the wallplate provided. For cooling only, or 
heating/cooling, order the 137421A (198170A for 
textured designer model) Heating-Cooling Wallplate with 
remote switching, or the Q539 Subbase that provides 
switching at the thermostat location.

The spdt switch makes one set of contacts on a 
temperature fall to operate the heating system. The other 
set of contacts makes on a temperature rise to operate 
the cooling system when the T87F is used to control 
cooling.

Models with positive Off feature break the electrical 
circuit to prevent system operation when the switch is 
moved to the Off position. These models use the 
137421B Wallplate for cooling or heating/cooling 
systems.

Heat anticipation is adjustable, 0.1 to 1.2A.

MERCURY NOTICE

If this control is replacing a control that contains 
mercury in a sealed tube, do not place your old 
control in the trash.

Contact your local waste management authority 
for instructions regarding recycling and the 
proper disposal of this control, or of an old control 
containing mercury in a sealed tube.

INSTALLATION AND SETTING

When installing this Product…

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a hazard-
ous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

IMPORTANT

The T87F was carefully adjusted at the factory. 
Handle the thermostat carefully; rough handling 
can decrease its accuracy.

CAUTION

Electrical Hazard. 
Electrical shock can cause personal injury or 
equipment damage.

Disconnect power supply before beginning 
installation.

CAUTION

Equipment Damage Hazard.  
Causing terminal shorts can burn out heat 
anticipator.

Do not short across relay coil terminals.

Location

Select a location about 1.5m (5 ft) above the floor in an 
area with good air circulation at average temperature.

Do not mount thermostat where it can be affected by:
— drafts or dead spots behind doors and in corners.
— hot or cold air from ducts.
— radiant heat from the sun or appliances.
— concealed pipes and chimneys.
— unheated (uncooled) areas behind the thermostat.

Mounting subbase wallplate (Fig. 2)

IMPORTANT

1. Use spirit level to accurately level the wallplate 

or subbase; see Fig. 1. Inaccurate leveling can 
cause thermostat control deviation.

2. When using the T87F with a Q539 Subbase, fol-

low the mounting and wiring instructions 
included with the subbase.

1.

Place wallplate on wall at desired location. Pull 
thermostat cable through entrance hole.

2.

Fasten wallplate but do not tighten screws.

Summary of Contents for T87F

Page 1: ...roduct 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazard ous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instruction...

Page 2: ... in a typical oil system Low voltage power for control circuit is supplied by transformer in oil primary control Fig 4 T87F used for 2 wire spst control of heating only in a typical gas system Fig 5 T87F replacing Series 10 Thermostat connected to 3 wire open contact high limit control SPIRIT LEVEL LEVELING POSTS 2 MOUNTING SLOTS M3319A OPENING FOR THERMOSTAT WIRING M5324 WALLPLATE SHOWN THERMOSTA...

Page 3: ...icipator indicator to match the amme ter reading NOTE A slightly higher setting to obtain longer burner on times fewer cycles per hour may be desir able for some systems RECALIBRATION The T87F is calibrated at the factory recalibration should not be necessary If the thermostat is accurately leveled but continues to be out of calibration order 104994A Calibration Wrench Instructions for recalibrati...

Page 4: ...THERMOSTAT Printed in U S A on recycled paper containing at least 10 post consumer paper fibers Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Scarborough Ontario M1V 4Z9 ...

Reviews: