background image

Complete

installation

5

Prepare Receiver Box

for installation

2

Install the

Receiver Box

3

B)

 Surface wiring

C)

 Replace the cover

min 0.25mm

2

 

max 1.5mm

2

Needed during installation:

 
    Cable with 2 wires from the boiler to Receiver Box.

    The Receiver Box requires 230V power   

     

Install Guide

 

Before installation of the 

Receiver Box

 

Find a suitable location near 
to the boiler. Leave at least 
30cm distance from any 
metal objects including 
wallboxes and boiler 
housing.  

Loosen the front 

screw to remove 
cover or tighten it
when the cover is 
back in place.

Max 6 mm

Please refer to the wiring 

diagrams over the page

32308181-008 B

After 
powering up both 
devices the green
LED is on.

  Turn ON mains power to the Heating Appliance and Receiver Box.

Push the buttons to 
check if the boiler 
switches on.
Buttons light green.

After power up, 
SETUP is displayed
on the thermostat’s
screen.

To rebind the units, reset the Receiver box, then press the button for 3 seconds. 
The LED on the receiver box will blink yellow to indicate the box is in binding 
mode. On the thermostat press         for 5 seconds to enter the advanced menu. 
Navigate to Binding, clear the current binding then bind the device again.

Reset

EN

A)

 Wall box or Rear Wiring

Hinge open the terminal block flap 
to access the cables and wall box 
screw holes.

Use the cable clamps to secure the 
surface wiring.

Locate the 
hinges at the top 
of the cover and 
wall plate, close 
the cover and 
secure with the 
screw.

Turn OFF the power

and remove the old thermostat

1

To ensure your safety, 

always make sure mains power is switched OFF

 before 

accessing wiring. 
In case of removing the old thermostat be aware that

 

the

 existing wiring will 

no longer be used.

  

The T6R-HW thermostat should not be placed near draughts, in direct 
sunlight or near heat sources.

WEEE Directive 2012/19/EC Waste Electrical and Electronic 

Equipment directive

At the end of the product life dispose of the packaging and product in a 
corresponding recycling centre. Do not dispose of the unit with the usual 
domestic refuse. Do not burn the product.

 

Must be installed by a competent person!

Read these instructions carefully. Failure to follow these instructions 
can damage the product or cause a hazardous condition.

 

Manufactured for and on behalf of the Environmental and Energy Solutions Division of 
Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland 
by its Authorised Representative Honeywell Inc.

Need help?

 

For assistance please visit: 

getconnected.honeywell.com

Honeywell Control Systems Ltd.,
Skimped Hill Lane,
Bracknell,
Berkshire,
RG12 1EB

Lyric T6R-HW Smart Thermostat

Compatible with Sundial Y- and S-plan stored hot water 
systems with zone valves. Also compatible with 24-230V 
on/off appliances such as gas boilers, combi-boilers and 
heat pump.

Approvals

Conforms to protection requirements of the following directives: 

EMC: 2014/30/EU

,

LVD: 2014/35/EU

 

and

 

RED: 2014/53/EU.

 

Hereby, Honeywell, declares that this thermostat is in 

compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. 
The full text of the EU Declaration of Conformity is available at the following Internet address:

 

http://hwll.co/DoC

RF (868MHz):

 Receiver Category 2, Max RF Power 25mW, 868–868.6MHz (868.3MHz)

Wi-Fi (2.4GHz):

 Max Power 100mW, 2.4–2.458Ghz

ErP:

 Class VI (+4%), (EU) 811/2013

Install the

Lyric T6R-HW thermostat

4

Choose the appropriate plug.
Place the thermostat on an even, horizontal surface and plug it in.

1.70 m

Summary of Contents for T6R-HW

Page 1: ...1EB Lyric T6R HW Smart Thermostat Compatible with Sundial Y and S plan stored hot water systems with zone valves Also compatible with 24 230V on off appliances such as gas boilers combi boilers and heat pump Approvals Conforms to protection requirements of the following directives EMC 2014 30 EU LVD 2014 35 EU and RED 2014 53 EU Hereby Honeywell declares that this thermostat is in compliance with ...

Page 2: ... existing wiring will no longer be used The T6R HW thermostat should not be placed near draughts in direct sunlight or near heat sources WEEE Directive 2012 19 EC Waste Electrical and Electronic Equipment directive At the end of the product life dispose of the packaging and product in a corresponding recycling centre Do not dispose of the unit with the usual domestic refuse Do not burn the product...

Page 3: ...eceiver Box The Receiver Box requires 230V power Before installation of the Receiver Box Find a suitable location near to the boiler Leave at least 30cm distance from any metal objects including wallboxes and boiler housing Loosen the front screw to remove cover or tighten it when the cover is back in place ...

Page 4: ...se refer to the wiring diagrams over the page A Wall box or Rear Wiring Hinge open the terminal block flap to access the cables and wall box screw holes Use the cable clamps to secure the surface wiring Locate the hinges at the top of the cover and wall plate close the cover and secure with the screw ...

Page 5: ...Install the Lyric T6R HW thermostat 4 Choose the appropriate plug Place the thermostat on an even horizontal surface and plug it in 1 70 m ...

Page 6: ...tches on Buttons light green After power up SETUP is displayed on the thermostat s screen To rebind the units reset the Receiver box then press the button for 3 seconds The LED on the receiver box will blink yellow to indicate the box is in binding mode On the thermostat press for 5 seconds to enter the advanced menu Navigate to Binding clear the current binding then bind the device again Reset ...

Page 7: ...to setup using the App is currently unsupported Set Up and configuration 6 SETUP SETUP LANGUAGE CLOCK SETUP 1 Touch to begin setting up the thermostat 2 Select your language 3 Set the clock format time and date SETUP CONFIGURE W ...

Page 8: ...DING RESET FAILSAFE English Heat HW 6 ON 0 off 1 on OFF 0 off 1 on 0 0ºC 1 5 ºC to 1 5ºC Bind check RF and clear bind Factory schedule WiFi and HomeKit reset Clock format 1 12h 2 24h Setup time and date 1 minute 3 6 9 or 12 Daily Opt start OFF Opt stop OFF Opt start 0 off 1 on 2 Delayed start Opt stop 0 off 1 on Format 24h Time Date 01 09 16 1 2 3 4 or 5 minutes Min 5 0ºC Max 35 0ºC 1 Daily schedu...

Page 9: ...See boiler specifications for correct terminals C Wiring for Combi boiler Receiver Box T1 T2 Boiler D Wiring for OpenTherm boiler Receiver Box Boiler T1 T2 Boiler Receiver Box V4043 V4043 Cylinder thermostat 1 2 Mid Position zone valve Boiler Receiver Box V4073A Cylinder thermostat 1 2 For security reasons route this wiring through conduit or in the wall so it is not accessible ...

Reviews: