Y PLAN

SUNDIAL Y PLAN

FEATURES

Independent control of

heating zone

Independent control of domestic

hot water temperature

Pump & boiler switched off when space

and hot water temperature requirements

are satisfied

Both systems can operate at

the same time

OPTIONS

Programmable thermostat in

heating zone to provide

‘Best Practice’ system

Radiator thermostats may be fitted

to provide temperature control

in selected rooms/areas

CM Zone can provide wireless boiler

interlock for individual radiator control

APPLICATION

The Sundial Y Plan is designed to provide independent

temperature control of both heating and domestic hot water

circuits in fully pumped central heating installations.

Sundial Y Plan satisfies the minimum standard requirements

of the Building Regulations Part L1 when used in conjunction

with radiator thermostats and an automatic bypass valve.

For systems in dwellings with a floor area greater than 150m

2

,

Sundial S Plan Plus must be used (see 2.3).

T6360

ROOM
THERMOSTAT

V4073

3 PORT
MID
POSITION
VALVE

L641

CYLINDER
THERMOSTAT

TIMER