Honeywell SS500 Series Installation Instructions Download Page 1

 

Installation Instructions for the 

ISSUE 5

SS500 Series Temperature Compensated  
Hall Effect Sensors

 

PK 80079

 

  WARNING 

PERSONAL INJURY 

DO NOT USE these products as safety or 
emergency stop devices or in any other application 
where failure of the product could result in personal 
injury. 

Failure to comply with these instructions could 
result in death or serious injury. 

 

CAUTION 

ELECTROSTATIC DISCHARGE DAMAGE 

This component is sensitive to electrostatic discharge 
(ESD). Take normal ESD precautions in handling this 
product to prevent ESD-induced damage and/or 
degradation.  

Failure to comply with these instructions will 
result in product damage. 

 

CAUTION

 

WAVE SOLDER DAMAGE 

DO NOT wave solder this product. Wave soldering 
may negatively affect the sensor performance and 
reliability. Subjecting the sensor to wave soldering 
will void Honeywell’s warranty.

  

Failure to comply with these instructions will 
result in product damage.

 

ABSOLUTE MAXIMUM RATINGS* 

Supply Voltage 

-1 to +30 VDC 

Voltage externally 
applied to output 

+30 VDC max. (OFF only) 
-0.5 VDC min. (OFF or ON) 

Output ON Current 

See Table A. 

Operating Temperature 

-50 to +160°C  
(-67 to +320°F) 

Storage Temperature 

-65 to +160

°

C  

(-85 to +320

°

F) 

Magnetic Flux 

No limit. Circuit cannot be 
damaged by magnetic 
overdrive. 

* Absolute maximum ratings are the extreme limits that the 
device will withstand without damage to the device. 
However, the electrical and mechanical characteristics are 
not guaranteed as the maximum limits (above 
recommended operating conditions) are approached, nor 
will the device necessarily operate at absolute maximum 
ratings. 

 

SOLDERING INSTRUCTIONS 

Honeywell recommends an infrared reflow process 

with peak temperatures not to exceed 245°C (473°F) 
for 10 seconds maximum. 

 

BLOCK DIAGRAM 

 TRIGGER

 CIRCUIT

   AND

AMPLIFIER

SENSOR

 HALL

GROUND (-)

Vs (+)

OUTPUT

(0) N.H.

 

OPERATING CHARACTERISTICS 

(over Operating Voltage and Temperature, unless otherwise noted)

 

 Min. 

Typ. 

Max. 

Remarks 

 

TABLE 

Supply Voltage 

3.8 

 30  VDC 

 

Output Current 

Absolute Limits 

Current Consumption 

 

 10  mA 

 

Supply 
Voltage 

Output 
Current 
Max. mA 

Output Voltage (operated) 

 

0.15 

0.40 

Sinking 20 mA max. 

 

-1 to 24 

50 

Output Current (operated) 

 

 

20 mA 

 

 

24 to 25 

37 

Output Leakage Current (released) 

 

 10 

µ

 

 

25 to 26 

33 

Output Switching Time 

 

 

 

V

CC

 = 12 V, 

 

26 to 27 

28 

Rise, 10 to 90% 

 .05 

µ

s 1.5 

µ

s R

L

 = 1.6 K 

 

28 to 29 

19 

Fall, 90 to 10% 

 .15 

µ

s 1.5 

µ

s C

L

 = 20 pF 

 

29 to 30 

15 

Operating Temperature Range 

-40

°

C to +125

°

C (-40

°

F to 302

°

F)  

  

Note:

 To prevent damage to the leads, SS500 Series surface mounted sensors are 

supplied 

only

 on tape and reel. 

 

Sensing and Control 

Summary of Contents for SS500 Series

Page 1: ...60 C 85 to 320 F Magnetic Flux No limit Circuit cannot be damaged by magnetic overdrive Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device However the electrical and mechanical characteristics are not guaranteed as the maximum limits above recommended operating conditions are approached nor will the device necessarily operate at absolute max...

Page 2: ...x Op 60 140 120 180 400 85 180 Min Rel 60 140 15 70 215 85 180 Min Dif 12 20 15 15 30 50 190 125 C Max Op 65 140 123 190 410 100 180 Min Rel 65 140 15 60 200 100 180 Min Dif 12 20 8 10 30 50 160 150 C Max Op 70 140 125 200 420 110 185 Min Rel 70 140 10 55 185 110 185 Min Dif 10 20 5 5 30 50 140 NOTICE Bipolar Hall effect sensors may have an initial output in either the On or Off state if powered u...

Page 3: ...only mm in TAPE DIMENSIONS for reference only mm in NOTE This product is sold in tape and reel form only per EIA STD 481 There are 1 000 parts per reel REEL DIMENSIONS for reference only mm in For application help call 1 800 537 6945 Honeywell Sensing and Control 3 ...

Page 4: ...Buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use While we provide application assistance personally through our literature...