1126800
SmartPAC 2 with WPC Integration
Page 46
Chapter 2
Installing SmartPAC 2 and WPC
Wiring the Overrun Sensor Magnetic Switch
NOTICE
You can run both the resolver wires and the overrun limit switch cable through the same
conduit. If you do this, wait to cut the cable and wires until both the resolver and the overrun
limit switch are installed.
Run the magnetic switch’s cable through conduit to the WPC. Connect the wires to terminal
blocks on the WPC control board, as shown in the table below. See also the Figure 3 wiring
diagram at the end of the manual. You will install the overrun sensor magnet as part of the
initialization process, after you finish the installation procedures in this chapter.
Table 2 - 1. WPC Overrun Sensor Magnetic Switch Wiring
Pin #
Connection
Wire color
23
+24 VDC
Red
24
Overrun input to WPC
White or Clear
25
Ground
Black
Summary of Contents for SmartPAC 2
Page 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Page 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Page 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Page 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Page 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Page 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Page 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Page 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...