SmartPAC 2 with WPC Integration
1126800
SmartPAC 2 Initialization Mode
Chapter 4
page 247
Switch 7 –Disable Changes to Stop Time Limit and Auto Carry-up Angle
NOTICE
After you change switch settings, power down the SmartPAC 2/WPC. Power it up again to
enable the new settings. If you do not this, the previous switch settings will remain in effect.
With this switch OPEN, you can change the settings for Stop Time Limit and Auto Carry-up
Angle. When this switch is set to CLOSED, you cannot change these settings.
Table 4 - 10. Switch 7 Setting to Enable/Disable Changes to Stop Time Limit
and Auto Carry-up Angle
Option Switch 7 Setting
Changes to
Stop Time Limit and Auto Carry-up Angle
OPEN
Enabled
CLOSED
Disabled
NOTICE
CHANGE FROM PREVIOUS VERSIONS OF WPC: TOP STOP IN INCH DISABLED WITH
INPUT PIN 13
To disable top stop in inch, connect on the WPC processor board, connect Pin # 13 to
+24 VDC. (Previous versions used Switch 7)
Summary of Contents for SmartPAC 2
Page 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Page 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Page 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Page 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Page 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Page 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Page 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Page 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...