1126800
SmartPAC 2 with WPC Integration
Page 134
Chapter 2
Installing SmartPAC 2 and WPC
Check the Emergency-Stop Circuit
DANGER
!
INJURY DURING TESTING
Keep all personnel away from the press during testing.
Ensure that there is no die or other tooling in the press during testing.
Failure to comply with these instructions will result in death or serious injury.
Run the press in Continuous mode, and depress the EMERGENCY STOP button. The press
should Emergency-stop immediately.
•
If the press Emergency-stops, go to the next test.
•
If the press does not Emergency-stop, there is a problem in your E-stop circuit.
Recheck all wiring and correct any problems. Re-run this test. If the press still does
not Emergency-stop, contact Wintriss Tech Support. Do not run the press or continue
with this checkout procedure until the press E-stops correctly.
NOTICE
CHECKING THE EMERGENCY-STOP CIRCUIT IN SINGLE STROKE MODE
If your press does not run in continuous mode, run this test while the press is making a
stroke in Single Stroke mode.
Summary of Contents for SmartPAC 2
Page 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Page 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Page 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Page 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Page 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Page 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Page 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Page 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...