Honeywell RTY Series Installation Instructions Manual Download Page 1

 

 

 

Sensing and Control 

 

GENERAL INFORMATION 

The RTY Series uses a magnetically biased, Hall-effect 
integrated circuit (IC) to sense rotary movement of the actuator 
shaft over a set operating range. Rotation of the actuator shaft 
changes a 

magnet’s position relative to the IC. The resulting 

flux density change is converted to a linear output.  

MOUNTING INFORMATION 

Mount the sensor using the two easily accessible mounting 
holes and non-magnetic stainless steel M5 screws with flat 
washers. Mounting screw tightening torque is 2,5 N m 
±0,5 N m [22.1 in lb ±4.4 in lb]. In harsh applications, treat the 
screw threads with a suitable thread locking compound.

 

 

Table 1. Specifications

 

Characteristic 

Parameter 

LV (Low Voltage) 

HV (High Voltage) 

Supply voltage 

5 ±0.5 Vdc 

10 Vdc to 30 Vdc 

Supply current 

20 mA max. 

32 mA max. 

Supply current (during output to ground short) 

25 mA max. 

47 mA max. 

Output 

0.5 V to 4.5 V ratiometric 

0.5 V to 4.5 V non-ratiometric 

Output signal delay 

4 ms typ. 

Overvoltage protection 

10 Vdc 

 

Reverse polarity protection 

-10 Vdc 

-30 Vdc 

Output to ground short circuit protection 

continuous 

Output load resistance (pull down to ground)  

10 kOhm 

EMI: 

radiated immunity 
conducted immunity 

 

100 V/m from 200 MHz to 1000 MHz per ISO11452-2 

100 mA BCI per ISO11452-4 

from 1 MHz to 200 MHz 

100 mA BCI per ISO11452-4 

from 1 MHz to 400 MHz 

EMC 

exceeds CE requirements 

Operating temperature range 

-40 °C to 125 °C [-40 °F to 257 °F] 

Storage temperature range 

-40 °C to 125 °C [-40 °F to 257 °F] 

Ingress protection  

IP67 according to DIN 40050 

Expected life 

35 M cycles  

Media compatibility 

heavy transportation fluids  

Housing material 

PBT plastic 

Shock 

50 G peak 

Vibration 

20 G peak tested from 10 Hz to 2000 Hz 

Resolution 

12 bit 

Termination 

AMP super seal connector 

Mechanical end stop 

no 

Approvals 

CE 

 
Figure 1. Mounting Dimensions (For Reference Only: mm/[in].) 

22,0

[0.87]

26,0

[1.02]

9,5

[0.37]

        5,35 DIA.

[0.21]

37

[1.46]

55

[2.17]

5,9

[0.23]

8,3

[0.33]

        15,50 DIA.

[0.61]

4,60

[0.18]

13,8

[0.54]

15,6

[0.61]

4,12

[0.16]

25

[0.98]

36,4

[1.43]

0  

A

C

B

Pin 1

Pin 2

Pin 3

        2,0 DIA.

[0.078]

        6 DIA.

[0.24]

        32,0 DIA.

[1.25]

0  

/2 

0  

/2 

R

T

Y

X

X

X

X

X

X

X

X

Y

Y

D

D

M

M

S

S

S

S

 

A

 = Left output: 0.5 Vdc 

B

 = Zero reference 

C

 = Right output: 4.5 Vdc 

Pinout 

N  

(North 

American) 

(European) 

 

Pin 1

 = VCC 

Pin 2

 = GND 

Pin 3

 = Output 

Pin 1

 = GND 

Pin 2

 = VCC 

Pin 3

 = Output  

NOTICE 

Ferrous or magnetic material 
within a 75 mm [2.95 in] radius 
from sensor center may affect 
sensor performance.

 

Summary of Contents for RTY Series

Page 1: ... continuous Output load resistance pull down to ground 10 kOhm EMI radiated immunity conducted immunity 100 V m from 200 MHz to 1000 MHz per ISO11452 2 100 mA BCI per ISO11452 4 from 1 MHz to 200 MHz 100 mA BCI per ISO11452 4 from 1 MHz to 400 MHz EMC exceeds CE requirements Operating temperature range 40 C to 125 C 40 F to 257 F Storage temperature range 40 C to 125 C 40 F to 257 F Ingress protec...

Page 2: ...warranty details If warranted goods are returned to Honeywell during the period of coverage Honeywell will repair or replace at its option without charge those items it finds defective The foregoing is buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose In no event shall Honeywell be liable for cons...

Page 3: ... sensing ranges provides flexibility in multiple applications allowing OEMS the range of travel needed for the application Potential applications include position and movement detection of pedals throttles gear shift levers steering linkages and hitches trucks buses off road vehicles industrial construction agricultural vehicles and equipment cranes suspension displacement kneeling buses trucks ti...

Page 4: ...g More are turning to Honeywell for more value Honeywell S C RTY and RPN Series Hall effect rotary position sensors respond to the presence or to the interruption of a magnetic field using a solid state Hall effect IC to sense rotary movement of the actuator shaft and then producing a proportional output The IC circuitry and magnets are galvanized with an integral connector more than a match for t...

Page 5: ...ox programmable output ratiometric to supply Input current 20 mA max 5 mA typ Operating temperature range 40 C to 125 C 40 F to 257 F 40 C to 85 C 40 F to 185 F Connector AMP 1 1419168 1 AMP Superseal 282087 1 Deutsch DT04 3P solder lug flying wire leads Life 30 M cycles 10 M cycles EMI EMC EMC 200 V m ISO 11452 3 EMI 30 V m 10 kHz to 1000 MHz at 3 m Housing material PA66 plastic metal Dimensions ...

Page 6: ...ywell will repair or replace at its option without charge those items it finds defective The foregoing is buyer s sole remedy and is in lieu of all warranties expressed or implied including those of merchantability and fitness for a particular purpose In no event shall Honeywell be liable for consequential special or indirect damages While we provide application assistance personally through our l...

Page 7: ...e the customer with known quality and support FEATURES AND BENEFITS competitive differentiator 35 M cycle product life Provides long life in the application Solid state Hall effect technology Provides non contact operation long service life low torque actuation and reduces worn out mechanisms Rugged IP67 sealed package with integral connector Allows for use in harsh environments Automotive grade E...

Page 8: ... kOhm EMI radiated immunity conducted immunity 100 V m from 200 MHz to 1000 MHz per ISO11452 2 100 mA BCI per ISO11452 4 from 1 MHz to 200 MHz 100 mA BCI per ISO11452 4 from 1 MHz to 400 MHz EMC exceeds CE requirements Operating temperature range 40 C to 125 C 40 F to 257 F Storage temperature range 40 C to 125 C 40 F to 257 F Ingress protection IP67 according to DIN 40050 Expected life 35 M cycle...

Page 9: ...ngle Linearity Error 1 Accuracy Error 2 Output Voltage Vdc Actuator Position 0 5 2 5 4 5 25 30 35 45 60 90 135 25 30 35 45 60 90 135 0 0 0 0 0 0 0 0 0 A B C Clamp High Clamp Low Notes 1 The linearity error is the deviation of the measured value from the best fit line and is the quotient of the measured output ratio deviation from the best fit line at the measured temperature to the best fit line o...

Page 10: ...oregoing is buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose In no event shall Honeywell be liable for consequential special or indirect damages While we provide application assistance personally through our literature and the Honeywell web site it is up to the customer to determine the suitabili...

Reviews: