background image

RTH6360 Series

Programmable Thermostat

Quick Installation Guide

Tools you will need

Tools you may need

Wire stripper

Needle-nose pliers

Drill and  

drill bit (7/32 in)

Included in your box

Screws and 

anchors

UWP™  

Mounting 

System

(UWP)

RTH6360 

Thermostat 

Quick Install Guide

Small flat head screwdriver

Phillips screwdriver

Pencil

Level

Summary of Contents for RTH6360 Series

Page 1: ... Tools you will need Tools you may need Wire stripper Needle nose pliers Drill and drill bit 7 32 in Included in your box Screws and anchors UWP Mounting System UWP RTH6360 Thermostat Quick Install Guide Small flat head screwdriver Phillips screwdriver Pencil Level ...

Page 2: ...f the power at the breaker box or switch that controls your heating cooling system 3 Remove the old thermostat s faceplate On most thermostats you can take off the faceplate by grasping and gently pulling Some thermostats may have screws buttons or clasps Do not remove any wires from your thermostat at this time 75 75 OFF OFF ON OFF ON Breaker box Switch 4 Make sure there are no 120 240V wires Do ...

Page 3: ...0 thermostat does not need jumpers Y R RC Example of a jumper Terminals 7 Record if you have wires in the following terminals Do not include jumpers as a part of your count The thermostat does not need jumpers Terminal Wire Color R Rh Rc 8 Write down the color of the wires Check mark the wires that are connected to terminals Next to the check mark write down the color of the wire Do not include ju...

Page 4: ...uld match the letter on the terminal Tip To prevent wires from falling back into the wall wrap the wires around a pencil Installing your RTH6360 thermostat 10 Bundle and insert wires through the UWP Pull open the UWP and insert the bundle of wires through the back of the UWP Make sure at least 1 4 inch of each wire is exposed for easy insertion into the wire terminals RTH6360 Thermostat Screws UWP...

Page 5: ... a 7 32 drill bit Insert wires into the inner holes of the terminals on the UWP The tabs will stay down once the wire is inserted If you have 1 R wire R Rh or Rc If you have 2 R wires R or Rh and Rc or 1 Set R switch to the up position 1 Set R switch to the down position 2 Insert your R wire R Rh or Rc into R terminal 2 Insert your Rc wire into Rc terminal 3 Insert your R or Rh wire into R Termina...

Page 6: ... Install batteries Insert two AA alkaline batteries in the back of the thermostat as shown 17 Attach your thermostat Align the thermostat onto the UWP and firmly snap it into place 13 Connect wires from Step 8 Depress the tabs to put the wires into the inner holes of their corresponding terminals on the UWP one wire per terminal until it is firmly in place Gently tug on the wires to verify they ar...

Page 7: ...nth Press Select Press or to adjust the day Press Select 20 Choose a clock format Press or set the clock format 12 hour standard for North America or 24 hour Press Select 21 Set the time Press or to adjust the hour Press Select Press or to adjust the minutes Press Select OFF ON ON OFF ON Breaker box Switch Set date and time NOTE If this is not a new installation see pages 15 16 for setting the dat...

Page 8: ...mmable 2 5 2 Programmable Note You can change default MO FR SA SU schedule here To edit periods during days temperature setpoints or to turn Schedule On Off touch MENU and go to SCHEDULE 125 Temperature Indication Scale 0 Fahrenheit 1 Celsius 200 Heating System Type 1 Conventional Forced Air Heat 2 Heat Pump 3 Radiant Heat Boiler 5 None Cool Only Note This option selects the basic system type your...

Page 9: ...ting and cooling to maintain the desired indoor temperature To be able to select automatic system mode on thermostat home screen turn this feature ON Turn OFF if you want to control heating or cooling manually 425 Smart Response 0 No 1 Yes Note Smart Response is a comfort setting Heat or Cooling equipment will turn on earlier ensuring the indoor temperature will match the setpoint at the scheduled...

Page 10: ...he next available System mode 2 Cycle through the modes until the required System mode is displayed and leave it to activate NOTE Available System modes vary by model and system settings System modes Auto Thermostat selects heating or cooling as needed Heat Thermostat controls only the heating system Cool Thermostat controls only the cooling system Em Heat only for heat pumps with auxiliary heat T...

Page 11: ...bove program schedules see page 12 1 Press Menu on your thermostat 2 If PROG is displayed press Select If Hold is displayed press then Select Then ON is displayed Press Select 3 Press or to select day or set of days to edit Press Select 4 Press or to select a schedule period to edit Wake Away Home and Sleep Press Select 5 ON is displayed Press Select to keep the schedule period on Or press and the...

Page 12: ...press or and then press Cancel Wiring conventional systems Alternate wiring conventional systems If labels do not match terminals connect wires as shown below see notes below NOTES 1 If you must connect both R and Rc wires set the R Slider Tab to the down position 2 wires 2 If your old thermostat had both R and RH wires set the R Slider Tab to the down position 2 wires Then connect the R wire to t...

Page 13: ... your old thermostat had separate O and B wires attach the B wire to the C terminal If another wire is attached to the C terminal stop now and contact a qualified contractor for help 4 If your old thermostat had Y1 W1 and W2 wires stop now and contact a qualified contractor for help 5 C does not power the thermostat display or operations batteries are always required 6 This model doesn t support t...

Page 14: ...etup numbers NOTE See System Setup options on page 8 for a full list of System Setup numbers and options 4 Press or to change values or select from available options 5 Press Select to save changes and advance to the next System Setup number 6 Once you have cycled through all of the System Setup numbers Done is displayed Press Select to save and exit To save and exit early press Home to return to t...

Page 15: ...appears about two months before the batteries are depleted Even if the low battery icon does not appear you should replace batteries once a year or before leaving home for more than a month If batteries are inserted within two minutes the time and day will not have to be reset All other settings are permanently stored in memory and do not require battery power NOTE When replacing batteries alkalin...

Page 16: ...ce menu You will see PROG or Hold Press or until F C is displayed 2 Press Select 3 You will see F or C displayed 4 Press or to adjust to the desired setting F for Fahrenheit and C for Celsius Press Select to save and exit Setting degrees Fahrenheit F or Celsius C Alert screen 1 You will see the alert icon on the home screen You can access alerts in the Menu to view the error alert code Once viewed...

Page 17: ...place the thermostat 173 Thermostat Temperature Sensor Error The sensor of the thermostat has encountered an error Please replace the thermostat 181 Replace Air Filter 1 Replace air filter 1 Reset the timer by touching the dismiss button on thermostat screen after it is replaced 405 Low Battery Alert The batteries are getting low Replace them within two months 407 Critical Low Battery The batterie...

Page 18: ...g and cooling equipment see pages 8 and 9 Heating or cooling system does not respond Press System to set system to Heat Make sure the temperature is set higher than the Inside temperature Press System to set system to Cool Make sure the temperature is set lower than the Inside temperature Check circuit breaker and reset if necessary Make sure power switch at heating cooling system is on Make sure ...

Page 19: ...Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of inci...

Page 20: ...e UWP CAUTION MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube do not place the old control in the trash Contact your local waste management authority for instructions regarding recycling and proper disposal CAUTION ELECTRICAL HAZARD Can cause electrical shock or equipment damage Disconnect power before beginning installation ALERT HHW PROPER DISPOSAL Th...

Reviews: