18
www.honeywell.com
PW7K1R1E Wiring and Setup
Status LEDs
Figure 2-7: Relay Circuit Wiring Diagram
Note:
The initial charge of the battery may take up to 24 hours to be fully charged.
2.13 Status LEDs
At power up, LED 1 turns ON then LEDs 2 through 7 are turned ON then OFF in
sequence.
Table 4:
LED’s in Normal Running mode
.
Diode Selection:
• Diode current rating: 1x
strike count
• Diode breakdown voltage:
4x strike voltage
• For 12VDC or 24VDC
strike, diode 1N4002
(100V/1A) typical
MOV Selection:
• Clamp voltage: 1.5x VAC
RMS
• For 24VAC strike,
Panasonic ERZ-
C07DK470 typical
+
-
TB6
2-C
NC
NC
NO
1
NO
1-C
O
TB6
1
NO
1-C
NC
NC
NO
2-C
LED
DESCRIPTION
1
On-line, encryption disabled = 0.8 second ON, 0.2 second OFF
On-line, encryption enabled = 0.1 second ON, 0.1 second OFF, 0.1 second
ON, 0.1 second OFF0.1 second ON, 0.1 second OFF0.1 second ON, 0.3
second OFF
Off-line: 0.2 second ON, 0.8 second OFF
Waiting for application firmware to be downloaded:.1 sec ON,.1 sec OFF
2
Input IN1 Status: OFF = Inactive, ON = Active, Flashing = Fault. See note
2
3
Input IN2 Status: OFF = Inactive, ON = Active, Flashing = Fault. See note
2
4
Input IN3 Status: OFF = Inactive, ON = Active, Flashing = Fault. See note
2