background image

Installation Instructions for OP Series 
Enclosed Switches

 

ISSUE 2

PK 88008

 

Sensing and Control 

 

  WARNING 

PERSONAL INJURY 

DO NOT USE these products as safety or emergency 
stop devices or in any other application where failure of 
the product could result in personal injury. 

Failure to comply with these instructions could 
result in death or serious injury. 

 

GENERAL INFORMATION 

OP switches are used in applications where the splash 
of oil, water or other liquids might hamper the operation 
of less-adequately protected switches. A gasket 
between cover and housing plus an O-ring shaft seal 
provide the seal for OP switches. OP switches are 

NOT

 

explosion-proof. 

Rotary OP's sealed construction provides protection 
from the entry of dust, water, oil and noncorrosive 
liquids as defined in NEMA 1, 3, 4 and 13. 

Since "Q" plunger actuators are not sealed, it is 
recommended that the switch be mounted so that liquids 
will not fall directly on the plunger. These plunger 
actuators meet NEMA 1 enclosure requirements. 

 

INSTALLING THE SWITCH 

A mounting bracket (15PA85-EX) is furnished at no 
extra cost with most OP switches. This permits all rotary 
operated switches to be mounted from top, bottom, back 
or right end. Plunger switches may be mounted on back, 
bottom or right end with this standard bracket. For top 
mounting of plunger switches, bracket 15PA86-EX must 
be purchased separately. 
 

ELECTRICAL RATINGS 

Electrical ratings of OP switches depend on the type of 
basic switch enclosed in the housing. Ratings are shown 
on page 2 along with letter keys (A, B, C, D) shown in 
table of listings on page 3. 

15PA85-EX 

Fasten bracket to switch with screws furnished. Bracket 
may be secured to mounting surface with .250" machine 
screws. 
 

 

 
15PA86-EX 

Fasten bracket to top of switch with screws furnished. 
Bracket may be secured to mounting surface with .250" 
machine screws. 
 

 

 

Summary of Contents for OP-AR

Page 1: ... actuators are not sealed it is recommended that the switch be mounted so that liquids will not fall directly on the plunger These plunger actuators meet NEMA 1 enclosure requirements INSTALLING THE SWITCH A mounting bracket 15PA85 EX is furnished at no extra cost with most OP switches This permits all rotary operated switches to be mounted from top bottom back or right end Plunger switches may be...

Page 2: ...ams or slides or by any other device which will impart side thrust to the plunger Use straight push action in the direction of the plunger motion Do not oil this plunger mechanism Sufficient grease of the proper type is assembled in the plunger during manufacture to last the lifetime of the switch Additional grease oil water or fine abrasive may cause jamming or electrical failure REPLACING BASIC ...

Page 3: ...DT 15 amp capacity A BZ 2R P4 8PA7 OP Note 2 OPA Q Overtravel plunger SPDT 20 amp capacity B BA 2R P4 Note 2 OPD Q Overtravel plunger DPDT 10 amp capacity C DT 2R A7 Note 2 OP AR50 Manual actuator paddle SPDT 15 amp capacity A BZ 2R P4 6PA134 OP 33PA3 OP 33PA7 EX 15PA85 EX OPD AR Roller arm CW actuation DPDT 10 amp capacity C DT 2R4 A7 6PA6 OP 33PA6 EX 15PA65 EX Note 1 Rotary external actuators sh...

Page 4: ...damages While we provide application assistance personally through our literature and the Honeywell web site it is up to the customer to determine the suitability of the product in the application Specifications may change without notice The information we supply is believed to be accurate and reliable as of this printing However we assume no responsibility for its use SALES AND SERVICE Honeywell ...

Reviews: