Product Description
Optional Modules and Accessories
4XTM Transmitter Module
The 4XTM provides a supervised output for local energy municipal box transmitter and alarm and
trouble reverse polarity. It includes a disable switch and disable trouble LED. A module jumper
option allows the reverse polarity circuit to open with a system trouble condition if no alarm condi-
tion exists. The 4XTM mounts to the main circuit board connectors J4 & J5.
N-ANN-80 LCD Annunciator
The N-ANN-80 is a remote LCD annunciator which mimics the information displayed on the
FACP LCD display and provides remote RESET, SILENCE, ACKNOWLEDGE, and DRILL.
N-ANN-80C LCD Indicator (Canadian applications)
The N-ANN-80C is a remote LCD indicator which mimics the information displayed on the FACP
LCD display but does
not
allow remote control of the FACP.
N-ANN-LED Annunciator Module
The N-ANN-LED Annunciator Module provides three LEDs for each zone: Alarm, Trouble and
Supervisory. N-ANN-LED module is installed in dress panel for Canadian version.
N-ANN-RLY Relay Module
The N-ANN-RLY Module, which can be mounted inside the cabinet, provides 10 Form-C relays.
N-ANN-S/PG Serial/Parallel Printer Gateway
The N-ANN-S/PG module provides a connection for a serial or parallel printer.
N-ANN-I/O LED Driver Module
The N-ANN-I/O module provides connections to a user supplied graphic annunciator.
ANN-SEC Secondary ANN-BUS Module
The ANN-SEC module provides another ANN-BUS port for more wiring flexibility and for Cana-
dian applications requiring remote annunciation.
DP-51050(B) Dress Panel
A dress panel DP-51050B (black) or DP-51050 (red) is available as an option. The dress panel
restricts access to the system wiring while allowing access to the membrane switch panel. The
Canadian version is supplied standard with a modified dress panel.
TR-CE Trim-ring
A trim-ring TR-CE (red) or TR-CE-B (black) is available as an option. The trim-ring allows semi-
flush mounting of the cabinet.
Battery Box
The NFS-LBB or BB-26 battery box may be used to house two batteries greater than 18 Amp Hour.
The battery box mounts directly below the control panel cabinet, centered to the main circuit board.
Battery Charger
CHG-75 Battery Charger
The CHG-75 is capable of charging up to 75 AH lead-acid batteries with the FACP. The FACP bat-
tery charger must be disabled, through software programming, when using the CHG-75. The char-
ger and up to 26 AH batteries can be housed in the BB-26 battery box. Larger batteries and the
charger can be housed in the NFS-LBB battery box which can be mounted up to 20 feet away from
the control panel. Refer to the
CHG-75 Manual
for additional information.
CHG-120 Battery Charger
The CHG-120 is capable of charging up to 120 AH lead-acid batteries with the FACP. The FACP
battery charger must be disabled, through software programming, when using the CHG-120. The
batteries and charger can be housed in the NFS-LBB battery box which can be mounted up to 20