WATER CONDENSATION DRAINAGE

When there is excess water condensation inside the unit, the air conditioner stops running and

shows a warning light. This warning light indicates that the water condensation needs to be drained 

using the following procedures:

Manual Draining for AC & Dehumidifier Mode

Water may need to be drained in high humidity areas.

Continuous Draining for Dehumidifier Mode

While using the unit in dehumidifier mode, continuous 
drainage is recommended.

WATER CONDENSATION DRAINAGE

1.
2.

3.
4.
5.

6.

Unplug the unit from power source.
Place a shallow pan under the lower drain plug. 
See diagram.
Remove the lower drain plug.
Water will drain out and collect in the shallow pan.
After the water is drained, replace the lower drain 
plug firmly.
You can now turn on the unit.

1.
2.

3.

4.

5.

Unplug the unit from the power source.
Remove the upper drain plug. While doing this 
operation some residual water may spill so 
please have a pan to collect the water.
Connect the drain connector to a ¾” hose (not 
included). See diagram.
The water can be continuously drained through 
the hose into a floor drain or sink.
You can now turn on the unit.

Lower
Drain Plug

Shallow Pan
(Not included)

Water Drain Pipe

Upper
Drain Plug

Summary of Contents for MP09 Series

Page 1: ...il info jmatek com Web www jmatek com Portable Air Conditioner User Manual Read and save these instructions before use Model MP09 Series MP09CES MP09CESBB MP09CESWW MP10 Series MP10CES MP10CESBB MP10CESWW ...

Page 2: ...the condensate through the air outlet hose There is no need to empty the drainage tank except in very high humidity conditions Read and follow the instructions carefully EN Follow installation instructions to set up the unit Plug the unit into a properly grounded circuit Important Before installing the unit place it UPRIGHT for 20 minutes before use to allow the refrigerant to stabilize Manually a...

Page 3: ...ng If service is needed contact an authorized service agent Unplug the unit when stored or not in use DO NOT run the power cord under carpeting and rugs Use caution to prevent tripping on cord DO NOT use in areas where gasoline paint or other flammable goods are stored Basic safety precautions should always be followed when using electrical appliances This appliance has been manufactured for use i...

Page 4: ... that all connections are tight and installed properly Note Do not install the window bracket to your window This step is required only to adjust it to the size of your window The bracket should be removed from the window after the size is adjusted INSTALLATION 1 2 3 4 5 Window Bracket Kit Window Bracket Panel Adapter Plastic Pin Hose Connector Plastic Hose 3 Installation Kit Installation Steps 1 ...

Page 5: ... by the product specifications Do not replace or lengthen it as this could cause the unit to malfunction Make sure the back of the unit is at least 50 cm 20 inches away from Do not place the unit in front of curtains or drapes as this could obstruct the airflow USE OPERATION TOUCH SCREEN CONTROL PANEL POWER CONTROL The Power Control turns the unit on and off MODE CONTROL 3 settings Cool Dehumidify...

Page 6: ...rs you want the unit to run in air conditioning mode AUTO TURN ON When unit is in a standby mode plugged in with power light on then press the or button to select the number of hours until you want the unit to automatically start running TEMPERATURE TIMER SET CONTROLS WARNING LIGHT Condensed water may accumulate in the unit If the internal tank becomes full the Power Control light will flash and t...

Page 7: ...itch off In stand by mode Auto switch on Press or button to adjust the time setting for 1 hour intervals Temperature Timer Set Mode Control Power Control Fan Speed Control Timer Control Battery Installation Remove the cover on the back of the remote control and insert two AAA batteries with and pointing in the proper direction according to the polarity markings Use only two AAA or IEC R03 1 5V bat...

Page 8: ...th plastic bag before storage to protect from dust and scratches collecting on the surface of the unit It is recommended to coil the power cord and store it away from the floor to ensure the cord is protected from bents and creases Remove the Plastic Hose from the unit by pulling away from the unit at the same time Remove the Window Bracket Window Bracket Panel Adapter and Hose Connector It is rec...

Page 9: ... 2 3 4 5 6 Unplug the unit from power source Place a shallow pan under the lower drain plug See diagram Remove the lower drain plug Water will drain out and collect in the shallow pan After the water is drained replace the lower drain plug firmly You can now turn on the unit 1 2 3 4 5 Unplug the unit from the power source Remove the upper drain plug While doing this operation some residual water m...

Page 10: ...hange remote control batteries Remove and reconnect the power cord Reset the safety LCDI plug if problem persists contact our customer support USA Canada only Lower the set temperature Make sure the exhaust hose is properly connected Connect exhaust hose as per instructions on page 4 Runs but no cooling A door or window is open The air filter is dirty The exhaust hose is detached Temperature setti...

Page 11: ...ek com Web www jmatek com 2015 JMATEK Limited All rights reserved The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representations or warranties with respect to these products These products are manufactured by JMATEK Limited ...

Reviews: