Honeywell MM14CCS Service Manual Download Page 1

220-240V 50Hz

MM14CCS

Important points on service, and flow chart 
for inspecting and repairing the unit ...............
Troubleshooting .............................................
Appearance and unit dimensional ................... 
Operation ....................................................
Technical specifications ..............................
Refrigerator system and schematic wiring 
diagrams ........................................................
Exploded view ................................................
Parts list ..................................................

This ma nual is for the use of technical personnel entr usted 

with ma intenance.

Air tek reser ve s the right to change this por table air 

conditioner’s casing, circuit and par ts without notice.

MM14CCS_SM_ENG_1

Date: 06/02/2014

SERVICE MANUAL

1
2
3

4-5

6

7
8

9-11

STOP

Portable

 

Air

 

Conditioner

14,000BTU

Cooling

LCD display

Single hose

Summary of Contents for MM14CCS

Page 1: ...erator system and schematic wiring diagrams Exploded view Parts list This manual is for the use of technical personnel entrusted with maintenance Airtek reserves the right to change this portable air conditioner s casing circuit and parts without notice MM14CCS_SM_ENG_1 Date 06 02 2014 SERVICE MANUAL 1 2 3 4 5 6 7 8 9 11 STOP Portable Air Conditioner 14 000BTU Cooling LCD display Single hose ...

Page 2: ...ing any electrical components they should be factory approved units Be sure that any electrical components are properly wired and in place PLUG AND SOCKET ARE LOOSE RE PLUGING THE POWER SUPPLY CORD AIR CONDITIONER WON T COOL PROPERLY AIR CONDITIONER WON T START COMPRESSOR WON T START TIMER FAILURE CHANGE THE PROTECTOR RUNNING TEST RE CONNECTING NO POWER PROTECTOR FAILURE USE OXYACETYLENE AND PLUS ...

Page 3: ...nd water full indicator lights If the set temperature is close to you can low the set temperature Air outlet be blocked by obstacle Take the obstacle away room temperature If the door or window open If there is other heater appliance work like heater or lamp etc The air filter is dirty please clean it Air outlet or intake be blocked Set temperature is too high Drain the water into a prepared conta...

Page 4: ...l Wheels Air exhaust for air to be cooled filtered Front Panel Handles Air inlet for air to be cooled filtered Air outlet Air filter Electricity cable Water drain Air inlet UNIT DIMENSIONAL 506 6 401 6 864 3 Water outlet drain ...

Page 5: ...h no cooling Note unit does not need to be vented in Fan mode Fan Speed Control The Fan Speed Control has 3 settings High Medium and Low Timer Auto turn off With machine in running mode press timer button to select number of hours you would like the unit to run in air conditioning mode until it automatically shuts off Auto turn on With machine in stand by mode press timer button to select number o...

Page 6: ...All batteries should be replaced at the same time Do not dispose of the batteries in a fire as they may explode Fan Speed Key Timer Temperature Buttons Power Key On Off On Off Timer Key In running mode Auto switch off In standby mode Auto switch on LOW HIGH MED Used for adjusting the timer and thermostat The default display is room temperature When or button is pressed the set temperature is displ...

Page 7: ... CONDENSER REFRIGERANT WEIGHT REFERENTIAL USING AREA 506 6W 506 6H 401 6D 220 240 50 1400 420 1160 35 400 RSH6870S1 DC12V 0 09A 4 450 2 2 O D 1 0 I D 700 L 2 3 R20S19FPI MM14CCS 14000 12 21 1 9 35 5 OPERATING CYCLE MODEL OUTPUT POWER INDOOR MOTOR LS 23D3 4P 23 2 450 OPERATING CYCLE MODEL OUTPUT POWER OUTDOOR MOTOR LS 53D1 4P 53 EVAPORATOR 3R14S19FPI mm 2 m V Hz B T U L H W 3 M hr W uF V mm uF V R4...

Page 8: ... 7 REFRIGERATOR SYSTEM DIAGRAM EVAPORATOR CONDENSOR COMPRESSOR CAPILLARY FILTER SCHEMTIC WIRING DIAGRAM ...

Page 9: ...1 Version 1 0 53 23 22 15 19 21 18 20 32 38 28 33 30 31 29 11 13 14 4 7 6 5 61 9 60 2 1 3 34 35 27 16 37 36 12 46 ACCESSORIES 62 63 64 65 66 67 54 47 48 40 49 56 41 58 59 25 26 24 52 51 50 55 57 17 39 6 44 43 68 45 69 42 8 10 70 71 ...

Page 10: ...509 640 A2510 200 A6101 920 AF 11 A6101 800 AF 11 A5825 050 AF 11 A5702 080 A 22 A3419 341 A5301 590 A 22 A5304 310 A 22 A3001 760 A5301 600 A 22 A7204 040 A2509 120 A6101 510 AF 11 BASE PAN TURNING WHEEL DRAIN BUCKET COVER B DRAIN BUCKET COVER A TANK LID FLOAT MICRO SWITCH FIX TURE WATER MOTOR WT 15D1 03 BLADE COMPRESSOR ASS Y 44N110 A1 RUBBER DISCHARGE PIPE SUCTION PIPE CONDENSER ASS Y CAPILLARY...

Page 11: ...912 A AF A4230 371 C 22 A5805 400 A 11 A5805 390 A 11 A4219 900 A FV A7301 650 A 22 D7324 030 D7306 050 H 22 D7324 020 A7305 010 A 22 A6200 070 A5815 090 H BS A4239 290 P BS A5700 520 A5700 530 A5700 540 A7437 010 A2530 580 AF01 CONTROL BOARD FIX TURE FIX TURE SENSOR FOR INDOOR POWER SUPPLY CORD COMPLETE DISCHARGE GRILLE BOLT BEARING GEAR WHEEL BUSHING VAN AIR DEFLECTOR VAN AIR DEFLECTOR BAR FRONT...

Page 12: ... 11 PARTS LIST MM14CCS NO 71 72 73 74 75 76 77 78 79 80 MATERIAL CODE PARTS NAME QUANTITY PRICE 1 A5311 030 A 11 BLADE ...

Page 13: ...e mail info honeywellportableac com www honeywellportableac com Jmatek Group Co e mail info jmatek com PSC 2012 07 July 2012 2012 AirTek International Corporation Ltd Hong Kong All rights reserved The Honeywell Trademark is used under license from Honeywell International lnc Honeywell International Inc makes no representation or warranties with respect to these products c ...