94
43-TV-25-30 Iss.6 GLO Aug 07 UK
If Pen 1 name is Furnace1, Tag is “Temperature”, the current value is 14.81, and the Unit
text is “Deg C”.
Embedded process variables can be used for Pen reports.
Embedded variable are not case sensitive and spaces are allowed.
Event Effects (continued)
•
Logging -
Is an event effect that can Start or Stop logging, enter which one in Sub
Type. From Selection Type choose either Multiple pens, Pen group or All Pens and
select the relevant pen(s) below.
•
Totaliser -
Is an event effect that can Start, Stop, Reset or Reset and Start a Totaliser in
Sub Type. From Selection Type choose either Multiple pens, Pen group or All Pens and
select the relevant pen(s) below.
•
Digital Outputs -
Is an event effect that can switch a Digital Output On or Off. Enter
which one in Sub Type and select the relevant relay output(s)
•
Alarm Acknowledge -
this is an effect of an event that can acknowledge a latched
alarm on a Single Pen, Pen Group or All pens. Select the pen and the number of alarm
to be acknowledged.
•
Email –
Is an event effect that will send an Email when triggered by a Cause. Eg.
Cause = Totaliser Starts, Effect = Email is sent.
• • Sub Type - Auto, Single Line User or Multiline User. Auto will enter what the
Event was eg. Scheduled or Alarm triggered. Single Line User can have up to
69 characters of text or use
“Embedded Process Values” on page 91.
Multiline User can have up to 80 characters per line with up to 1000 characters
including spaces, carriage returns and line feed in total. They can also include
embedded process variable.
“Maths variables as embedded vari-
can be used in an email.
• • Recipients - Enter email recipients from the list. If no email recipients are
present. For setting up email recipients see
Summary of Contents for Minitrend QX
Page 2: ...ii 43 TV 25 30 Iss 6 GLO Aug 07 UK User manual ...
Page 50: ...44 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 192: ...186 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 210: ...204 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 242: ...236 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 249: ...43 TV 25 30 Iss 6 GLO Aug 07 UK 243 Multitrend SX Recorder 14 15 32 46 50 30 31 35 36 28 55 ...
Page 250: ...244 43 TV 25 30 Iss 6 GLO Aug 07 UK 52 11 23 33 39 5 6 RS485 USB host Ethernet 1 2 3 4 ...
Page 254: ...248 43 TV 25 30 Iss 6 GLO Aug 07 UK eZtrend QXe Recorder 16 5 3 1 4 2 24 49 9 45 19 6 49 ...
Page 258: ...252 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 274: ...268 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 276: ...270 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 296: ...290 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 308: ...302 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 312: ...306 43 TV 25 30 Iss 6 GLO Aug 07 UK ...
Page 323: ......