The RF6GB is a wireless glassbreak detector intended for use with Honeywell controls that support SiX™
Series devices.
Mounting
The RF6GB can be mounted
on the wall or on the ceiling.
•
within 7.6 m (25 feet) of the
protected glass;
•
within clear view of the
protected glass;
•
at least 2 m (6.5 feet) from the
floor;
•
at least 1 m (3.3 feet) from
forced air ducts;
•
at least 1 m (3.3 feet) from
sirens or bells greater than 5
cm (2 inches) in diameter.
•
between the protected glass
and any heavy window
coverings.
•
when heavy window coverings
are present, the detector can
be mounted on the window
frame.
•
Avoid mounting the detector
on the same wall as the
protected glass, on free-
standing posts or pillars, or in
rooms with noisy equipment
(air compressors, bells, power
tools, etc.), if this equipment is
operated when the detector is
armed.
•
UL requirements:
TBD
To remove the mounting bracket:
Turn the top of the detector 15 degrees
counter-clockwise and separate the
mounting bracket.
Note: Before mounting the RF6GB
permanently, conduct Go/No Go tests (see
control’s instructions) to verify adequate
signal strength and adjust the device location
and orientation as necessary.
•
The RF6GB can be mounted on the wall
or on the ceiling.
•
The rear tamper plate MUST be mounted
to a stud, solid wood, or with a robust
wall anchor.
BETA DRAFT – 01/12/15