69-2655EFS-01

System Types

•  Gas, oil, or electric heat with air 

conditioning

•  Warm air, hot water, high 

efficiency furnaces, heat pumps, 
steam, gravity

•  Heat only — including power 

to open and close zone valves 

(Series 20), and normally open 

zone valves

•  Heat only with fan
•  Cool only
•  750 mV heating systems

This thermostat contains a Lithium battery which may contain Perchlorate material.

Perchlorate Material—special handling may apply, 

 

See www.dtsc.ca.gov/hazardouswaste/perchlorate

MERCURY NOTICE

This thermostat does not contain mercury. However, do not place your old thermostat in the trash 

if it contains mercury in a sealed tube. Contact the Thermostat Recycling Corporation at www.

thermostat-recycle.org or 800.238.8192 for information on how and where to properly and safely 

dispose of your old thermostat.

CAUTION: SHOCK HAZARD

Can cause electrical shock or equipment damage. If not avoided, could result in 

minor or moderate personal injury. Disconnect power before beginning installation or 

servicing.

Technical Assistance

  |  24 hours a day, 7 days a week  |  www.lutron.com

 

U.S.A.  / Canada: 1.800.523.9466  |  Mexico: +1.888.235.2910

 

Other Countries: +1.610.282.3800  

Warranty:

 For warranty information, please see the Warranty enclosed with the product, or visit 

www.lutron.com/resiinfo

Summary of Contents for LR-HWLV-HVAC

Page 1: ...ardouswaste perchlorate MERCURY NOTICE This thermostat does not contain mercury However do not place your old thermostat in the trash if it contains mercury in a sealed tube Contact the Thermostat Recycling Corporation at www thermostat recycle org or 800 238 8192 for information on how and where to properly and safely dispose of your old thermostat CAUTION SHOCK HAZARD Can cause electrical shock ...

Page 2: ...in 5 mm holes for drywall Drill 7 32 in 6 mm holes for plaster Wall anchors Wire hole Mounting screws Grasp top and bottom of wallplate and pull to remove from thermostat M29480 RF Device Placement The thermostat must be within 30 ft 9 m of an RF signal repeater CAUTION Thermostat should be installed by a climate control specialist to avoid damage to the equipment ...

Page 3: ...power failure this is an indication that the coin cell needs to be replaced You should replace the battery every five years or before leaving home for an extended period Remove tab The TouchPRO Wireless thermostat is shipped from the factory with the coin cell installed To keep the battery from discharging during shipment and storage the TouchPRO Wireless thermostat is shipped with a plastic tab i...

Page 4: ...nsformer 3 Y 1st stage compressor contactor Y2 2nd stage compressor contactor Aux E Auxiliary heat relay G Fan relay L Heat pump reset powered continu ously when System is set to Em Heat system monitor when set to Heat Cool or Off O B Changeover valve for heat pumps K Optional THP9045 Wiring Module Terminal 9 S1 S2 Optional remote sensor Wiring guide heat pump systems 1H 1C Heat Pump no auxiliary ...

Page 5: ...er 1 2 W Heat relay Y Compressor contactor G Fan relay C 24 V common 3 4 K Optional THP9045 Wiring Module Terminal 9 S1 S2 Optional remote sensor Heat Only System With Fan Rc Power 1 R R Rc joined by jumper W Heat relay G Fan relay C 24 V common 3 S1 S2 Optional remote sensor Cool Only System Rc Power 1 R R Rc joined by jumper Y Compressor contactor G Fan relay C 24 V common 3 K Optional THP9045 W...

Page 6: ... will verify the battery is functioning correctly 1 After receiving time and date from the TouchPRO Wireless thermostat remove the thermostat from the wallplate 2 Wait 10 seconds and replace the thermostat 3 After a few seconds the thermostat should return to its normal display If it does you are done 4 Remove the battery tray adjust the metal tabs for good contact and verify battery polarity 5 Re...

Page 7: ...t 0 None 1 Yes 0220 1st Stage Cool Compressor cycle rate 3 Recommended for most compressors other options 1 2 4 5 or 6 CPH 0230 2nd Stage Cool Compressor cycle rate 3 Recommended for most compressors other options 1 2 4 5 or 6 CPH 0240 First stage heat cycle rate CPH cycles per hour 5 Gas or oil furnaces of less than 90 efficiency 1 Steam or gravity systems 3 Hot water systems furnaces of 90 effic...

Page 8: ...only 1 Balance point Failed to Maintain Heat protection 2 Low lockout High Lockout Failed to Maintain protection in between 0346 Dual Fuel Heat Pump Upstage to Furnace Timer 0 Disabled 0 5 0 5 hours 1 1 hour 1 5 1 5 hours 2 2 hours 3 3 hours 4 4 hours 5 5 hours 6 6 hours 8 8 hours 10 10 hours 12 12 hours 14 14 hours 16 16 hours 0347 Drop Temperature 2 2 ºF 1 0 ºC 3 3 ºF 1 5 ºC 4 4 ºF 2 0 ºC 5 5 ºF...

Page 9: ... 13 180 C Days 14 365 C Days 0502 Furnace filter reminder run time equipment counts 0 Counts heat and cool 1 Counts cool only 0510 Humidifier Pad Replacement Reminder 0 Disabled 1 90 C Days 30 R T Days 2 180 C Days 60 R T Days 3 365 C Days 90R T Days 0520 UV Lamp Replacement Reminder 0 Disabled 1 365 Days 2 730 Days 2 years 0580 Compressor protection 5 5 minute compressor OFF time Other options 0 ...

Page 10: ...rol recommended 1 Choose if room is cooler than set temperature 3 Choose if room does not reach set temperature 0700 Temperature display offset 0 Thermostat displays actual room temperature Other options 3 ºF 2 ºF 1 ºF 1 ºF 2 ºF 3 ºF offset 1 5 ºC 1 0 ºC 0 5 ºC 0 5 ºC 1 0 ºC 1 5 ºC 0710 Reset 0 No reset 1 Reset HVAC installer options to factory default only date and time settings are retained and ...

Page 11: ...em 0 OFF 1 Heat Stage 1 2 Heat Stages 1 2 3 Heat Stages 1 2 3 4 Heat Stages 1 2 3 4 4 Emergency heating system 0 Em Heat OFF 1 Em Heat stage 1 2 Em Heat stage 1 2 3 Em Heat stage 1 2 3 During installer setup press q repeatedly until Test appears Test number System status Press q to select test Press q to change status Press DONE to terminate testing System test System status EQUIPMENT DAMAGE HAZAR...

Page 12: ...show Device Is Unaddressed at the top of the screen 1 To activate thermostat press MORE The thermostat will now show the connection screen and display Press Connect at the top of the screen 2 Press the CONNECT button The CONNECT button will blink and the thermostat will display Addressing at the top of the screen 3 Return to the Lutron software and confirm thermostat activation When activated the ...

Page 13: ...0 ºF to 99 ºF 10 0 ºC to 37 0 ºC Operating Ambient Temperature 0 ºF to 120 ºF 18 ºC to 49 ºC Shipping Temperature 30 ºF to 150 ºF 34 ºC to 66 ºC Operating Relative Humidity 5 to 90 non condensing Physical Dimensions 4 15 16 in H x 6 9 16 in W x 1 7 16 in D 125 mm H x 166 mm W x 36 mm D Electrical Ratings Terminal Voltage 50 60 Hz Running Current W Heating 20 30 V 0 02 1 0 A Powerpile 750 mV 100 mA...

Page 14: ...l com Lutron Electronics Co Inc 7200 Suter Road Coopersburg PA 18036 1299 USA TEL 1 610 282 3800 FAX 1 610 282 1243 www lutron com Technical Assistance 24 hours a day 7 days a week www lutron com U S A Canada 1 800 523 9466 Mexico 1 888 235 2910 Other Countries 1 610 282 3800 Warranty For warranty information please see the Warranty enclosed with the product or visit www lutron com resiinfo ...