Honeywell L506 Installation Manual Download Page 1

 

 

www.inncom.com

 

L506 Wireless Lamp Control  
Module Installation Guide 

The L506 FET 

dimmer can drive 

dimmable CFL 

loads and other 

loads: 

 

100W 

Incandescent 

 

35W Dimmable CFL or 100W 

incandescent equivalent 

 

25W LED or 100W 

incandescent equivalent 

As an alternative to the L206 lamp 

socket module, the L506 provides 

wireless lamp control with a smaller 

footprint. Designed for standard 

medium lamp sockets (E26 Edison), 

the RF-equipped device can be 

controlled from any INNCOM IRAS 

device with an RF transceiver. The 

socket is equipped with a mechanical 

button that can control the load and 

assist in device binding. The L506 

series will eventually incorporate 

sibling products designed for other 

lamp socket types. 

Installation 

The installer must be a trained, 

experienced service technician. 

When installing this product: 

1.  Read the instructions carefully. 

Failure to follow them could 

damage the product or cause 

hazardous conditions. 

2.  Check the ratings given in the 

product guide to make sure the 

product is suitable for your 

application.. 

3.  Use the L506 module 

only with a recognized 

or listed lamp holder 

assembly. 

CAUTION:

 The distance 

between the bulb and the 

shade should be equal to or 

greater than required by the original 

UL listing for the lamp base. 

Improper placement is a fire hazard.  

Mounting  

The L506 may be mounted in 

vertical/bulb up, horizontal, or 

vertical/bulb down fixtures.

 

CAUTION: 

The bulb-down orientation should 

generally be confined to open air 

installations; if used with a shade, the 

fixture should be further derated (see 

table below).  

1.  If the lamp’s Edison socket has a 

switch, make sure it is in the full 

on position, then remove or 

disable it. 

2.  The L506 dimmer-equipped lamp 

must be within 60 feet (indoors) of 

an RF transceiver/repeater. 

3.  Unplug the lamp cord from the 

power source (e.g., wall socket). 

4.  Remove any shade and lamp 

harp. 

5.  Remove the bulb; screw the L506 

dimmer/switch into the lamp 

socket. 

6.  Reinstall the bulb, then the lamp 

harp (if used). Rotate the harp if 

necessary to clear the L506 

socket. Plug the lamp back into 

the power supply. 

Derating:

 Do not exceed an ambient 

air temperature of 25˚C surrounding 

the L506 Lamp Controller when 

operating the lamp with the specified 

loads and orientations, as outlined in 

the following table.  

Maximum Ratings 

 

Vertical 

Base Down 

(bulb up) or 

Horizontal 

Vertical 

Base Up 

(bulb 

down)* 

Incandescent 

100W 

60W 

Dimmable 
CFL 

35W 

20W 

LED 

25W 

10W 

*Open air only. If fixture enclosed, further 
derating is necessary 

Communications 

The L506 can switch on a light using 

the built-in on/off button. For remote 

and dimming operation, the L506 

must be located within 60 ft. of an 

originating RF transmitter (any IRAS 

RF device can be configured as a 

repeater). The L506 must be 

commissioned. The outline below 

assumes the installer understands 

the commissioning process in 

general; specific commissioning 

procedures can be found on the 

property-specific commissioning 

sheet. 

Commissioning 

The L506 must be bound to an RF 

control device such as an e528 

thermostat.  

1.  The L506 enters bind mode for the 

first 2 minutes after powering up; 

Reviews: