Document 800-04559
Rev D
71
11/09
Configuration
Figure 3-40
Alarm Out Settings Screen
Note
You can change the settings of relay alarm output in the No. 1.
2.
Each alarm output can be given its own title by highlighting the box under the Title
heading, then press
#
. A virtual keyboard appears allowing you to enter the title.
3.
Highlight the boxes under the Type heading to set the alarm output for NO or NC
(normally open or normally closed).
4.
Highlight the box beside Dwell Time, then press
#
to set the dwell time (from 5
seconds to 15 minutes) of the alarm output.
Alarm-Out Schedule
1.
On the Alarm-Out screen, highlight the Schedule tab to open the Schedule
screen.
Figure 3-41
Alarm-Out Schedule Screen
2.
You can add and edit alarm output schedules on this screen. Highlight the +, then
press
#
to add a schedule. Highlight the boxes under the Column heading, then
press
#
to edit the information in those boxes.