HPTV2404(CB) PRODUCT INSTALLATION DOCUMENT
PN 52404:A
01/17/2005
ECN 04-507
Honeywell Power Products
12 Clintonville Road
Northford, CT 06472
http://www.honeywellpower.com
HPTV2404(CB):
CCTV Power Supply and Distribution Units
1 Overview
The
HPTV2404
and
HPTV2404CB
are CCTV power supply and distribution units. They provide a constant source of
24 VAC with 4 A supply current. Four individual outputs route power to operate CCTV Cameras and other video
accessories. For overload protection the HPTV2404 uses automotive style fuses and the HPTV2404CB has auto-
resettable PTCs.
2 Specifications
•
Input 115 VAC, 60 HZ, 1 A.
•
4 A, 24 VAC (100 VA) supply current.
•
Four outputs
Note: Individual Output Circuits can be loaded to 3.0 A on HPTV2404 or 2.0 A on HPTV2404CB provided the total
current from all output combined is limited to 4.0 A.
•
Surge and transient protection.
•
Transformer has built in thermal protection.
•
LED Indicator Lights:
– Input Power LED (Green) – ON indicates that 24 VAC is present at distribution board
– Output Power LEDs (4 Green) – ON indicates that 24 VAC is present at the related output circuit.
•
Overload Protection (HPTV2404):
– Terminal Block Fuse: 3 A, 250 V, 5x20MM Cartridge
– Main Secondary Fuse: 5 A, 32 V, Automotive Style
– Individual Output Circuit Fuses: 3 A, 32 V, Automotive Style
•
Overload Protection (HPTV2404CB):
– Terminal Block Fuse: 3A, 250V, 5x20MM Cartridge
– Individual Output Circuit PTC: Hold Current (2.0 A at 50°C)
– SPECIAL NOTE: To reset a PTC that has experienced an overload or short circuit, disconnect power for 5 minutes
to allow the PTC to reset itself.
•
Power ON/OFF switch.
•
AC line cord included.
•
Unit maintains camera synchronization.
•
Vented enclosure with hinged door and five convenient knockouts.
•
Design for quick installation.
•
Maximum temperature range 32°F to 120°F (0°F to 49°C); indoor use only.
•
Cabinet dimensions 11.5" W x 4.875" D x 10" H (29.21 cm W x 12.38 cm D x 25.4 cm H)
3 Installation Instructions
1. Unpack product and discard all packing materials.
2. Pre-drill holes where enclosure is to be mounted.