• HPR12DC416UL • HPR12DC416CBUL • HPR12DC616UL
• HPR12DC616CBUL • HPR12DC616CE • HPR12DC616CBCE
CCTV Rack Mount Power Supply and Distribution Units
PN 52995:A 5/31/06 ECN 07-004
Honeywell
12 Clintonville Road
Northford, CT 06472
http://www.honeywellpower.com
Product Installation Document
1 Overview
These Honeywell Rack Mount CCTV power supplies will provide 12 VDC power distributed via 16 circuits for powering
CCTV cameras and other video equipment. Each circuit will be fuse protected at 3.0A, or PTC protected at 2.5A. Fuses
are accessible directly through the front panel by removing six screws.
2 Specifications
•
Input:
– HPR12DC416UL & HPR13DC416CBUL - 117V, 60Hz, 1A.
– HPR12DC616UL & HPR12DC616CBUL - 117V, 60Hz, 2A.
– HPR12DC616CE & HPR12DC616CBCE - 230V, 50/60Hz, 1A.
•
Output:
– HPR12DC416UL & HPR12DC416CBUL - 4A @ 12VDC.
– HPR12DC616UL & HPR12DC616CBUL - 6A @ 12VDC.
– HPR12DC616CE & HPR12DC616CBCE - 6A @ 12VDC.
•
16 outputs.
•
Maximum current rating:
– HPR12DC416UL: any output, 3A; total supply, 4A @ 12VDC.
– HPR12DC416CBUL: any output, 2.5A; total supply, 4A @ 12VDC.
– HPR12DC616UL: any output, 3A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
– HPR12DC616CBUL: any output, 2.5A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
– HPR12DC616CE: any output, 3A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
– HPR12DC616CBCE: any output, 2.5A; total supply, 6A @ 12VDC (8A for operations below 100°F, 38°C)*.
* Outputs 1 to 8 provide 3A @ 12VDC (4A operation below 100°F, 38°C) and outputs 9 to 16 provide 3A @
12VDC (4A operation below 100°F, 38°C).
•
16 power limited outputs.
•
Surge and transient protection.
•
Transformer has built-in thermal protection.
•
Indicator Lights:
– Input Power Indicator (1 red): Illuminated power switch/circuit breaker.
– Output Power LEDs (16 green): ON indicates that DC is present at the related output circuit.
•
Overload Protection:
– Input power switch has built-in circuit breaker.
– AC line fuse (5 x 20mm glass).
– Individual output circuits have a glass fuse (5 x 20mm) or resettable PTCs.
– NOTE: To reset a PTC that has experienced an overload or short circuit, switch power off for 5 minutes to allow
the PTC to reset itself.
•
Factory installed three-conductor AC line cord with North American NEMA 5-15 plug (117V supplies) or European
Schuko Type, CEE 7/7 plug (230V supplies).
•
2U rack chassis for use in standard EIA 19” rack.
Continued on next page...