HPTV24100WP • HPTV28100WP

PRODUCT INSTALLATION DOCUMENT

PN 52497:A 04/01/2005 ECN 05-092

Honeywell
12 Clintonville Road 
Northford, CT 06472
http://www.honeywellpower.com

1 Overview

HPTV24100WP and HP28100WP power supplies provide power for applications such as access control, security, and 
CCTV applications that require outdoor installation. The HPTV24100WP provides a non-power limited output of 24VAC 
@ a maximum of 4.0 Amps and the HPTV28100WP provides 28VAC (non-power limited) @ at maximum of 3.6 Amps 
of continuous supply current. Each unit consists of a thermally-fused transformer and an electrically-fused primary input 
in a NEMA 4X weatherproof enclosure with included mounting hardware.

2 Specifications

3 Installation Instructions

1. Unpack product and discard all packaging materials.
2. Pre-drill holes where enclosure is to be mounted. Choose a vertical surface, strong enough to support the full weight 

of the assembly. Outdoor installation only. Note the added dimensions of the required mounting brackets.

3. Use knockout punch, standard hole saw, or other means to make holes for incoming AC power and low voltage 

wiring. Non-power limited wiring must be wired using weatherproof conduit or suitable outdoor wiring. 

4. Secure enclosure to the desired location.
5. Disconnect power to the branch circuit.
6. Connect AC power to fused AC terminal block as shown in illustration.
7. Connect CCTV cameras (or other external loads) to appropriate output terminals. See illustration.
8. Secure door on weatherproof enclosure.
9. Power the branch circuit.

 

Continued on next page...

HPTV24100WP

HPTV28100WP

• Input: 115VAC, 60Hz 0.85A

• Input: 115VAC, 60Hz 0.9A

• Output: 24VAC, 4.0A max

• Output: 28VAC, 3.6A max

• Fuse Rating: 3A 5 x 20mm 250VAC

• Fuse Rating: 3A 5 x 20mm 250VAC

WARNING: Risk of electrical shock and/or equipment damage!

To reduce risk of electric shock, do not expose inside of unit to rain or excessive moisture, and disconnect power 
before servicing unit.

For continuous protection against hazard, replace fuses only with exact type and rating.

A readily accessible switched circuit breaker must be available to disconnect main power as required.

This unit contains no user-serviceable parts. Installation and servicing should only be made by qualified 
personnel. 

Install in accordance with all local regulations and the National Electrical Code.