background image

USB option

USB control

USB Enabled

USB Boot Support

Disabled

(*)

Removable Flash media boot sequence

External Drive keys first

USB Drive key Enumeration

Enabled

Processor options

No Execute memory protection

Enabled

Intel® Virtualization Technology

Enabled

Intel Hyperthreading options

Enabled

Processor Core disable

6

Intel turbo boost technology

Enabled

Intel VT-D

Disable

(*)

Num lock power on state

ON

(*)

Embedded SATA Configuration

Enable SATA legacy support

Enable

Driver write cache

Disabled

Power management options

HP power profile

Custom

(*)

HP power regulation

OS control Mode

(*)

Redundant power supply mode

Balanced mode

- 59 -

Chapter 5 - Servicing

Summary of Contents for HP ProLiant DL360P Gen8

Page 1: ...HP ProLiant DL360P Gen8 Server Planning Installation Service Guide HWDOC X330 G August 2020 ...

Page 2: ...al Sàrl While this information is presented in good faith and believed to be accurate Honeywell disclaims the implied warranties of merchantability and fitness for a purpose and makes no express warranties except as may be stated in its written agreement with and for its customer In no event is Honeywell liable to anyone for any direct special or consequential damages The information and specifica...

Page 3: ...ation 15 2 4 4 Cnet configuration using PCIC interface 15 2 5 Memory configuration 16 2 5 1 Standard memory configuration for 4GB using RDIMM 16 2 5 2 Standard memory configuration 17 2 5 3 Maximum memory configuration 17 2 6 System specifications 18 2 6 17 Hard disk drive specifications 22 2 6 18 Removable media specifications 22 2 6 19 Mouse and keyboard 22 2 6 20 Monitor 22 2 6 21 Video cable 2...

Page 4: ...erview 34 4 1 1 Front view 34 4 1 2 Rear view 35 4 2 Network connections 36 4 2 1 Ethernet network 36 4 2 2 LCN network 36 4 2 3 LCN cables 37 4 2 4 LCN connections 37 4 2 5 MAU connection 37 4 2 6 ControlNet Network 38 4 3 Configuring ControlNet interface card 39 Chapter 5 Servicing 40 5 1 Remove the server from the rack 40 5 2 Removing the access panel 40 5 3 Servicing the LCNP4e LCNp4e2 41 5 3 ...

Page 5: ...5 5 5 BIOS settings for 51155539 100 50 5 5 6 BIOS settings for 51155539 200 57 5 6 Spare parts 65 5 ...

Page 6: ...Interface provided via FTE This node may be installed as a physical or virtual platform If the node is upgraded to an ELCN node and the node is a physical a k a bare metal platform a Local Control Network Processor LCNP board coaxial interface to LCN is not used The LCN MAU is disconnected and or the LCNP board is removed Redundant ELCN Bridges are required if the ELCN node is communicating with a...

Page 7: ...ce Guide EPDOC XX36 en510A FTE system installation servicing troubleshooting Universal Embedded Appliance Hardware Installation and Maintenance Guide HWDOC X469 en A General UEA planning installation and service information before it is commissioned as an ELCN appliance Integrated Experion TPS User s Guide EPDOC XX66 en 510A Supplementary installation tasks needed before using TPS Nodes on an Expe...

Page 8: ... IT networks Experion R510 Software Change Notice EPDOC X166 en 510A Describes Experion R510 features enhancements overall product release interoperabilities system dependencies problem resolutions known issues special considerations Customer Release Guide R687 CRG 687 TPN TPS Migration information ELCN migration Information included TPN R687 Software Change Notice TNDOC X166 en 6871A Document cha...

Page 9: ...imilar HP model is considered a project special and its TAC support is limited according to the services policy This release of the server is based upon RAID 5 and dual power supply design and provides computer based functionality for Experion and TPS systems For TPS systems and certain Experion systems configured with Fault Tolerant Ethernet FTE the server has an LCNP4e LCNp4e2 card installed whi...

Page 10: ...sing Platform APP node or Experion Server ESVT ESV ACE SCE ACE T EAS eServer EApp Refer to the latest Experion General Release Software Change Notice for software applications that have been qualified for use on the HP ProLiant DL360p Gen8 server platform 2 1 2 BIOS configuration All HP ProLiant DL360p Gen8 server platforms must have the BIOS version P71 02 11 2014 or later 2 2 Description l Honey...

Page 11: ... Microsoft Windows Server 2008 32 bit COA MZ PCEH05 300 GB 2 5 15 K RPM SAS HDD to use as a Hotspare Not supplied with standard configuration The customer needs to buy it if hot spare is required 51155539 907 MZ PCEM35 8 GB ECC DDR3 RDIMM MEM EXP 1X8 GB 1600 MHz or faster 51155539 908 MZ PCSV82 Intel Xeon Processor E5 2630V2 15M Cache 2 6 GHz 7 20 GT s Intel QPI 8GB RDIMM 1x8GB 4 x300GB 15K RPM Se...

Page 12: ...as a hot spare and is optional You must order the 5th 300 GB 2 5 15K RPM SAS HDD separately using the model number P N MZ PCEH05 The server is shipped with a HP USB QWERTY keyboard and mouse However if you require a Honeywell supplied monitor then you must order it separately All mass storage devices are connected through SATA and PCIe SATA DVDRW drive is connected through the SATA connector on th...

Page 13: ...ble lists other Honeywell publications that may be useful when installing or operating the server platform Publication Contains information on FE05 Fault Tolerant Ethernet Installation and Service Guide Installing and using FTE 2 3 2 HP documentation The following table lists HP publications and other sources of information that is useful when installing operating and servicing the Honeywell serve...

Page 14: ...oneywell part number Description TP LCNP04 51405098 100 LCN Interface card PCIe TP LCNP05 51454493 126 LCN Interface PCIe Rev2 l Slot configuration for Experion node setup l Slots configuration l General Ethernet configuration l Cnet configuration using PCIC interface 2 4 1 Slot configuration for Experion node setup FTE Supervisory Default NIC1 and NIC2 onboard NIC Slot number Description Slot 1 S...

Page 15: ...up l Slots configuration l General Ethernet configuration l Cnet configuration using PCIC interface 2 4 3 General Ethernet configuration Single NIC One on board NIC Slot number Description Slot 1 Slot 2 Dual NICs Two on board NIC Slot number Description Slot 1 Slot 2 2 4 4 Cnet configuration using PCIC interface You must purchase the Magma PE3R PCie to PCI converter box separately and use it since...

Page 16: ...rm Honeywell model number Description MZ PCEM28 4 GB ECC RDIMM MEM EXP 1x4 GB 1600 MHz or faster MZ PCEM35 8 GB ECC RDIMM MEM EXP 1X8 GB 1600 MHz or faster l Standard memory configuration for 4GB using RDIMM l Standard memory configuration l Maximum memory configuration 2 5 1 Standard memory configuration for 4GB using RDIMM The following table provides the memory configuration for Intel Xeon E5 2...

Page 17: ... CPU1 Population order Channel 1 12 A 4GB RDIMM 11 E empty 10 I empty Channel 2 9 B 4GB RDIMM 8 F empty 7 J empty Channel 3 1 C empty 2 G empty 3 K empty Channel 4 4 D empty 5 H empty 6 L empty Tab 200 The following table provides the memory configuration for Intel Xeon E5 2630 V2 Ivy Bridge 2 60 GHz 8GB consisting of One 8 GB ECC RDIMM MEM EXP 1x8 GB 1600 MHz or faster Channels Slot numbers CPU1 ...

Page 18: ...MM Channel 3 1 4GB DDR3 ECC RDIMM Channel 4 4 4GB DDR3 ECC RDIMM If customer has 51155539 200 with base memory as 8GB 1x8GB Then order 2 No of MZ PCEM35 to make it 16GB Mounting will be as shown above 2 6 System specifications 2 6 1 Microprocessor Microprocessor Intel Xeon E5 2620 V2 or Intel Xeon E5 2630 V2 Ivy Bridge 80W Hexa Core Processor Level 2 Cache 1MB Level 3 Cache 15MB Chipset Intel C600...

Page 19: ...B Tab 200 16 GB 2x 8 GB DDR3 ECC RDIMM for faster 2 6 4 Raid controller RAID controller HP Smart Array P420i 512MB FBWC RAID 5 Configuration 4 HDD on RAID 2 6 5 Optical disk drive DVD drive SATA DVD R W 2 6 6 Video Video type Integrated Matrox G200 video standard 2 6 7 Network interface Adapter type 4 port PCIe express 4 lens HP Flexible LOM 2 6 8 Power The following provides the specifications fo...

Page 20: ...TENTION All temperature ratings described previously are for sea level An altitude derating of 1 C per 300 m 1 8 F per 1 000 ft to 3048 m 10 000 ft is applicable Direct sunlight is not allowed Operating humidity 10 to 90 non condensing with a maximum humidity gradation of 10 per hour Storage humidity 5 to 95 non condensing with a maximum humidity gradation of 10 per hour ATTENTION Storing maximum ...

Page 21: ...ives Hard Drive 4 x 146 GB or 300 GB 2 5 inch SAS 15K RPM hot plug drives hard drives 0 1 2 and 3 are in a RAID 5 configuration with hard drive 4 as a hot spare drive The hot spare must be purchased separately 2 6 15 External ports Serial One DB 9 connectors LAN 4 x RJ 45 SCSI External None USB Seven USB 2 0 ports Two in front four at the rear and one internal Video One port standard video at the ...

Page 22: ...he maximum weight and dimensions for 146GB hard drive Description Requirement Height 14 81 mm Width 70 mm Depth 100 5mm Weight 0 201 kg 2 6 18 Removable media specifications The HP ProLiant DL360p Gen8 server has one SATA DVD RW drive The SATA DVD RW drive is connected to the SATA connector on the motherboard DC 5 volt power 6 5 Watts is the operating power requirement for DVD RW drive 2 6 19 Mous...

Page 23: ... the HD15 connector are wired The IS supplied cable 51196742 200 is DDC compatible To use a front video adapter the customer needs to buy an HP DP to VGA dongle P N 655519 B21 For more information click here to access the Hewlett Packard customer support center 2 7 Industrial regulatory compliance The compliance specifications in this section apply to cabinet installations WARNING Honeywell does n...

Page 24: ...001 Am 2 l IEC 61010 1 2001 2nd edition ATTENTION In the above referenced standards is a Normative Reference section citing additional standards which may apply as suited and required for product compliance 2 8 Light industrial regulatory compliance The compliance specifications in this section apply to installations other than cabinets ATTENTION Honeywell does not claim Safety Compliance or Elect...

Page 25: ...he Portable Transceivers walkie talkies in Watts Examples P 10 Watts D 0 949 meters P 5 Watts D 0 671 meters P 1 Watt D 0 300 meters Electrical cables which are routed external to the equipment must be fully shielded cables 360 degree metallic shielding to comply with the above EMC standards 2 8 2 Safety compliance The following are the light industrial regulatory product safety compliance l CSA C...

Page 26: ...ecklist Tasks Understanding the Power and grounding requirements Also refer to TPN System Installation Guide SW20 600 Installing the server and connecting the cables Starting the server l Before you begin 3 1 1 Before you begin Ensure that you perform the following tasks l Ensure that the cabinet is properly grounded l Unpack the platform from the box and verify the parts l Place the server on a s...

Page 27: ...ts only one HP ProLiant DL360p Gen8 server can be mounted on a new build 1 meter deep Honeywell MP C1MCB1 cabinet The server must be mounted on rack space interval 11U through 15U counting from the bottom of the cabinet and moving up Install a 1U air duct baffle and blank front panel in the rails directly above the server The room ambient temperature must be kept between 10 dm and 30 dm C 50 dm to...

Page 28: ...ped from the Honeywell factory with pre assembled Sliding Ready Rails The Sliding Ready Rails II kit and 1U Cable Management Arm kit are included with the purchase of Honeywell part number 51155539 100 Model No MZ PCSV82 l Honeywell server back panel connections l Installing the server l Connecting the cables l Install air duct baffles and blank panel front covers in cabinet 3 4 1 Honeywell server...

Page 29: ...ol console for your human interface pre installed in the Honeywell factory connect the KVM cable mouse and keyboard connections to the USB connectors on the rear of the server The KVM cable may have separate USB connections for the mouse and keyboard or they may be combined into one USB connector through a USB to PS 2 adapter included with the KVM cable 3 4 3 Connecting the cables To connect the c...

Page 30: ...inet Air duct baffles and blank panel front covers ensure that the airflow within the cabinet allows proper cooling for the servers The following image illustrates the air duct baffles and blank panel front covers used in cabinet Figure 3 1 Air Duct Baffle and Blank Panel Front Cover To install air duct baffles and blank panel front covers in cabinet 1 Place the air duct baffle inside the cabinet ...

Page 31: ...ther side of the blank front panel to the left cabinet rail using two machine screws and two external tooth washers threaded into the two clip nuts and tighten the screws 4 Attach the rear mounting bracket to the rear cabinet rail using two thread forming screws and two external tooth washers and tighten the screws 5 Attach the air duct baffle to the rear mounting bracket using two machine screws ...

Page 32: ...l drives A list of Hard disk drives appears 4 Select four hard disk drives 5 Press TAB to navigate to the next window 6 Select RAID 5 that is x RAID 5 7 Press TAB to navigate to the next window 8 Uncheck the Use one drive as a Spare option that is x Use one drive as a Spare 9 In available physical drives ensure that the last hard drive is marked as S 7 10 Press TAB 11 After selecting hot spare in ...

Page 33: ...rm the following steps to verify the LCNP4e LCNp4e2 passed self test To check the LCNP4e LCNp4e2 status 1 Choose Start Programs Honeywell TPS LCNP Status 2 Verify that the LCNP status indicates Passed Self Test and the circle is green 3 Verify that the TPN Address appears in the LEDs field of the LCNP Status display after the Board 0 is configured for the node s TPN address You must reset the LCNP...

Page 34: ...Configuring ControlNet interface card 4 1 Server overview l Front view l Rear view 4 1 1 Front view The following image illustrates the front view of the HP ProLiant DL360p Gen8 server Following is the description for the items in the image 34 CHAPTER 4 ...

Page 35: ... 8 SAS SATA SSD drive bay 8 9 DVD ROM drive optional 10 Systems Insight Display 11 Front video connector front video port adapter required 12 USB connectors 2 13 Serial number tab 14 Power On Standby button and system power LED 4 1 2 Rear view The following image illustrates the rear view of the HP ProLiant DL360p Gen8 server Following is the description for the items in the image 35 Chapter 4 Ope...

Page 36: ...n l ControlNet Network 4 2 1 Ethernet network ETHERNET 10 100 1000 Base T connection is the standard connection used on the Honeywell configured platform An on board dual NIC must be used for FTE configuration 4 2 2 LCN network The connection to the LCN is made through a Local Control Network Processor LCNP4e LCNp4e2 card The LCNP4e LCNp4e2 card is a Honeywell PWA that allows the TPS Operator Stat...

Page 37: ...405098 100 and for the LCNp4e2 is TP LCNP05 with Honeywell part number 51454493 126 4 2 3 LCN cables The two LCN cables and with T connectors and terminators if applicable are routed vertically inside the left rear corner of the cabinet when viewed from the rear door near the vertical cable duct where the connection is made to the LCN MAU The cable between the LCNP4e LCNp4e2 board and the LCN MAU ...

Page 38: ...s in media from coax to fiber optic All points on the network must either have an interface card or a terminator Terminators are comprised of termination resistors which are used to mark the beginning and end of a trunk segment and Tap Dummy Load TDL which terminate a drop cable when no node is present The model number for the ControlNet Universal Interface is TC PCIC02 100 The following image dis...

Page 39: ...olutions support website https www honeywellprocess com library support Documents Experion Magma_Installation_ Instructions_HWDOC X279 en pdf 4 3 Configuring ControlNet interface card You can configure a ControlNet interface card using the Magma PE3R PCie to PCI converter box 1 For more information on the Magma PE3R PCie to PCI converter box log into honeywellprocess com 2 Enter your user name and...

Page 40: ...d if the Server has been upgraded to be an ELCN node 5 1 Remove the server from the rack Refer to the HP Quick Deploy Rail System Installation Instructions at the following HP website for removing the server from the rack http www8 hp com 5 2 Removing the access panel 5 2 1 To remove the access panel 1 Turn off the server 2 Disconnect the power cord from the power source 3 Disconnect the power cor...

Page 41: ...ch up as illustrated 6 Remove the top cover of the server and place it aside The inside of the server is accessible 5 3 Servicing the LCNP4e LCNp4e2 The LCNP4e LCNp4e2 board has 256 MB of on board memory Figure 5 1 LCNP4e Board 41 Chapter 5 Servicing ...

Page 42: ...Chapter 5 Servicing Figure 5 2 LCNp4e2 Board l Replacing the LCNP4e LCNp4e2 board 5 3 1 Replacing the LCNP4e LCNp4e2 board NOTE Only LCNP4e card replacement procedure is provided NOTE 42 ...

Page 43: ... steps to remove the access panel Refer to the section Removing the access panel 2 Locate the blue tab and lift the blue latch up as illustrated 3 To disengage the thumbscrew turn the blue latch 180 degrees counter clock wise as illustrated The following image illustrates the thumbscrew disengaged 43 Chapter 5 Servicing ...

Page 44: ...iser cage and remove it from the server 5 Place the PCI riser cage on a flat surface 6 While wearing a grounded ESD wrist strap grasp the LCNP4E card at the corners and gently remove the existing card 7 Insert the LCNP4E board in slot1 44 ...

Page 45: ... riser cage back in the server 9 Engage the thumbscrew turn the blue latch 180 degrees clock wise to engage the screw as illustrated 10 Replace the access panel 11 Install the server into the rack 45 Chapter 5 Servicing ...

Page 46: ... to the HP documentation listed in the following table for detailed instructions on swapping the power supply and hard disk drive Publication Contains information on HP ProLiant DL360 Gen8 Server Maintenance and Service Guide Service and maintenance HP ProLiant DL360 Gen8 Server User Guide Operation setup troubleshooting l Installing hot spare hard drive 5 4 1 Installing hot spare hard drive You c...

Page 47: ...ver NOTE In HP DL360p Gen8 Server 146 GB Hard disk drives MZ PCEH04 are obsolete and Customer may received replacement as 300 GB MZ PCEH05 Hard disk drives These drives can be used in RAID5 array with 146 GB Hard disk drives Usable capacity of will remain 146 GB as it will be part of Array 5 5 Servicing Honeywell options CAUTION Do not damage the EMI gasket fingers when removing installing boards ...

Page 48: ...ts for general Ethernet and FTE node setup The following table identifies the specific slots for each of the Honeywell options for general Ethernet and FTE node configurations Four Ethernet 10 100 1000 embedded Base T connections are standard on the Honeywell based HP ProLiant DL360p Gen 8 Server Platform The Broadcom dual embedded GB NICs are enabled without PXE in the System BIOS The default con...

Page 49: ...odule to be inserted into the socket 5 Insert the memory module as described in section Memory configuration 6 Align the memory module s edge connector with the alignment key on the memory module socket and insert the memory module into the socket ATTENTION The memory module socket has an alignment key that allows you to install the memory module in the socket only in one way 7 Press down the memo...

Page 50: ...ettings in the factory for each of the server platform configurations and these settings must not be altered BIOS settings for the server are listed in the tables The following table provides the default BIOS settings for two FTE configuration and general ethernet configurations BIOS setting FTE only No FTE but 1 or 2 ethernet ports Broadcom Dual Onboard NIC Use Onboard NICs NIC1 and NIC2 Use one ...

Page 51: ...r management controller 3 3 Memory configured 4096 or 8192 depending on the memory configuration Proc 1 Intel 2 10GHz 15MB L3 Cache Proc 2 Not Installed Serial port option Embedded serial port COM1 IRQ4 IO 3F8H 3FFH Virtual Serial Port Disabled Embedded NICs NIC1 boot options Network Boot NIC 2 boot options Disabled NIC3 boot options Disabled NIC4 boot options Disabled Advanced Memory Protection A...

Page 52: ...ection Enabled Intel Virtualization Technology Enabled Intel Hyperthreading options Enabled Processor Core disable 6 Intel turbo boost technology Enabled Intel VT D Disable Num lock power on state ON Embedded SATA Configuration Enable SATA legacy support Enable Driver write cache Disabled Power management options HP power profile Custom HP power regulation OS control Mode Redundant power supply mo...

Page 53: ...eaving Enabled Maximum PCI Express Speed Maximum Supported Dynamic Power Saving Mode response Fast Collaborative Power Control Enabled Dynamic Power Capping functionality Enabled DIMM Voltage preference Optimized for performance Memory power saving Mode Maximum Performance PCI Express Generation 3 control for select devices Embedded storage controller Enabled Embedded FlexibleLOM1 Enabled PCI E Sl...

Page 54: ...ia IRQ 5 Embedded HP Smart Array P420i Controller IRQ 3 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 1 IRQ 3 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 2 IRQ 5 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 3 IRQ 3 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 4 IRQ 5 PCI device enable disable Embedded Intel R SATA Controller 1 Enabled Embedded HP Sma...

Page 55: ...der Ctrl 1 PCI Embedded HP Smart array P420i Controller Ctrl 2 PCI Embedded Intel R SATA Controller 1 Date and Time Date mm dd yyyy XX XX XXXX Time hh mm ss XX XX XX Server availability ASR Status Enabled ASR timeout 10 min Thermal Shutdown Enabled WAKE On LAN Disabled Post F1 Prompt Delayed Power button Enabled Automatic Power On Always remains Off Power On Delay No delay 55 Chapter 5 Servicing ...

Page 56: ...d options Advanced System ROM Options Load Embedded devices first MPS Table Mode Full Table APIC ROM Selection Use Current ROM NMI debug option Enabled Virtual Install Disk Disabled PCI bus padding option Enabled Power On Logo Disabled F11 Boot Menu prompt Enabled Consistent device naming Disabled Network boot retry support Disabled Reset on boot device not found Disabled HP Option ROM Prompting E...

Page 57: ...ory channel mode Independent Channel Mode Non Lockstep ACPI Slit preferences Disabled Intel performance counter monitor PCM Enabled Asset Tag Protection Unlocked SR IOV Disabled System default option Restore Default System Setting No abort restore Restore Settings Erase Boot disk No Utility Language English 5 5 6 BIOS settings for 51155539 200 This section lists the BIOS settings configured in the...

Page 58: ...1 2014 This version can be older than displayed Boot Block 03 05 2013 Power management controller 3 3 Memory configured 4096 or 8192 depending on the memory configuration Proc 1 Intel 2 60 GHz 15 MB L3 Cache Proc 2 Not Installed Serial port option Embedded serial port COM1 IRQ4 IO 3F8H 3FFH Virtual Serial Port Disabled Embedded NICs NIC1 boot options Network Boot NIC 2 boot options Disabled NIC3 b...

Page 59: ... Virtualization Technology Enabled Intel Hyperthreading options Enabled Processor Core disable 6 Intel turbo boost technology Enabled Intel VT D Disable Num lock power on state ON Embedded SATA Configuration Enable SATA legacy support Enable Driver write cache Disabled Power management options HP power profile Custom HP power regulation OS control Mode Redundant power supply mode Balanced mode 59 ...

Page 60: ... Auto Channel interleaving Enabled Maximum PCI Express Speed Maximum Supported Dynamic Power Saving Mode response Fast Collaborative Power Control Enabled Dynamic Power Capping functionality Enabled DIMM Voltage preference Optimized for performance Memory power saving Mode Maximum Performance PCI Express Generation 3 control for select devices Embedded storage controller Enabled Embedded FlexibleL...

Page 61: ... Smart Array P420i Controller IRQ 3 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 1 IRQ 3 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 2 IRQ 5 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 3 IRQ 3 Flexible LOM1 HP Ethernet 1Gb 4 Port 331FLR Adapter Port 4 IRQ 5 PCI device enable disable Embedded Intel R SATA Controller 1 Enabled Embedded HP Smart Array P420i Contr...

Page 62: ...A Boot controller order Ctrl 1 PCI Embedded HP Smart array P420i Controller Ctrl 2 PCI Embedded Intel R SATA Controller 1 Date and Time Date mm dd yyyy XX XX XXXX Time hh mm ss XX XX XX Server availability ASR Status Enabled ASR timeout 10 min Thermal Shutdown Enabled WAKE On LAN Disabled Post F1 Prompt Delayed Power button Enabled Automatic Power On Always remains Off Power On Delay No delay 62 ...

Page 63: ...ystem ROM Options Load Embedded devices first MPS Table Mode Full Table APIC ROM Selection Use Current ROM NMI debug option Enabled Virtual Install Disk Disabled PCI bus padding option Enabled Power On Logo Disabled F11 Boot Menu prompt Enabled Consistent device naming Disabled Network boot retry support Disabled Reset on boot device not found Disabled HP Option ROM Prompting Enabled Video Option ...

Page 64: ...U Streamer Prefetcher Enabled DCU IP Prefetcher Enabled Node Interleaving Enabled Intel NIC DMA Channel Enabled Memory channel mode Independent Channel Mode Non Lockstep ACPI Slit preferences Disabled Intel performance counter monitor PCM Enabled Asset Tag Protection Unlocked SR IOV Disabled System default option Restore Default System Setting No abort restore Restore Settings Erase Boot disk No U...

Page 65: ... GB 15 K 6G 2 5 SAS DP HDD 652605 B21 51155539 903 Rack mount Rails HP 1U SFF Gen8 Rail Kit for HP DL360p 663201 B21 51155539 904 SMPS HP 460W CS Plat PL Ht Plg Pwr Supply Kit 656362 B21 51155539 905 DVD Drive HP 9 5mm SATA DVD RW Jb Kit 652241 B21 51155539 906 Hard Disk Drive Section HP 300 GB 12 G SAS 15 K 2 5 in SC ENT HDD 759209 B21 51155539 907 Expansion Ram HP 8 GB PC3L 12800R 11 Kit 731765 ...

Page 66: ...f any may be found in the materials accompanying the product in the documents or files accompanying such third party materials in a file named third_ party_licenses on the media containing the product or at http www honeywell com ps thirdpartylicenses Documentation feedback You can find the most up to date documents on the Honeywell Process Solutions support website at http www honeywellprocess co...

Page 67: ...te https www honeywellprocess com en US contact us customer support contacts Pages default aspx Training classes Honeywell holds technical training classes that are taught by process control systems experts For more information about these classes contact your Honeywell representative or see http www automationcollege com 67 ...

Reviews: