User Manual of Explosion-Proof Bullet Camera
10
Chapter 4
Basic Operations
In this and the following chapters, operation of the camera by the web browser will be taken as
an example.
4.1
Configuring Local Parameters
The local configuration refers to the parameters of the live view and other operations using the
web browser.
Steps:
1.
Enter the Local Configuration interface:
Configuration > Local
Figure 4-1
Local Configuration Interface
2.
Configure the following settings:
Live View Parameters:
Set the protocol type, play performance, rules and image format.
Protocol Type:
TCP, UDP, MULTICAST and HTTP are selectable.
TCP:
Ensures complete delivery of streaming data and better video quality, yet the
real-time transmission will be affected.
UDP:
Provides real-time audio and video streams.
MULTICAST:
It
’
s recommended to select the protocol type to
MULTICAST
when using
the Multicast function.
HTTP:
Allows the same quality as of TCP without setting specific ports for streaming
under some network environments.
Play Performance:
Set the play performance to Shortest Delay, Balanced, or Fluent.
Rules:
You can enable or disable the rules of dynamic analysis for motion here.