Template (entire sheet) Top of Humidifier

Template (entire sheet)

Te

mplate (e

nt

ir

e sh

ee

t)

Te

mp
late (entire sh

eet)

Fig. 5. Typical wiring diagram for humidifier using fan control to 

cycle blower motor fan and humidifier simultaneously.

Fig. 6. Typical wiring diagram of current sensing relay with 

humidifier.

Fig. 7.  Typical wiring diagram of sail switch with humidifier.

For H1008 Automatic Humidity Control wiring 
connections:

IMPORTANT

• Current sensing relay or sail switch is not needed with the 

Automatic Humidity Control.

• Use 18-22 gauge insulated wire for proper wiring. We 

recommend stranded - tinned wire.

Connect 24 Vac power to the 24 Vac HOT and COM terminals on 

the H1008A.

14.

Connect the humidifier to the two HUM terminals on the 

H1008A as shown in Fig. 8.

For additional mounting and wiring information, refer to the Humidity 

Control installation instructions.

For Perfect Climate Comfort Center

 Control 

connections:

1.

Connect only the two yellow wires to the W8900 (red wire con-

nections are not used). See the typical wiring diagram in 

Fig. 9.

For additional mounting and wiring information, refer to the Perfect 

Climate Comfort Center

 installation instructions.

Plumbing Saddle Valve

Hot or cold water, either hard or softened, can be used in the 

humidifier. 

1.

1.

Use the self-piercing saddle valve (included) to tap into the water 

supply line at an appropriate location.

CAUTION

Chemical Hazard.

Can cause personal injury or equipment damage.

Do not use any line connected to an air conditioner.

IMPORTANT

• •The saddle valve is not designed to regulate water flow; the 

valve is either open or closed.

• •To prevent debris from clogging the solenoid in-line filter, be 

sure to install the saddle valve handle pointing toward the 

ceiling.

NOTE: Lightly clean the copper tubing ends with fine sandpaper 

before making any connections.

Fig. 8. Typical wiring diagram for humidifier using TrueIAQ.

2.

Use 1/4 in. O.D. copper tubing and connect the saddle valve to 

the inlet side of the solenoid valve.

a. Place the brass compression nut over the copper tubing.

b. Slide the brass ferrule over the tubing. 

NOTE: Do not over-tighten the compression nut. Moderate 

tightness prevents leaking. 

c. Insert the tubing into the solenoid valve fitting and support 

the valve while tightening the compression nut. 

NOTE: Slope hose downward for correct drainage.

3.

Connect a 1/2 in. hose to the humidifier drain fitting and run it to a 

suitable drain.

CHECKOUT

1.

Open the saddle valve.

NOTE: The furnace blower must be on for the humidifier to 

operate.

2.

Set the thermostat setpoint 10°F (6°C) above the room

temperature.

3.

Set the humidity control to a high humidity setting, or place the 

setting in the test position.

4.

Observe the water running out of the drain line to be sure the 

humidifier is working correctly.

5.

Check for leaks.

6.

Reset the thermostat to a comfortable setting or the Automatic 

Humidity Control to the desired frost factor setting.

Fig. 9. Typical wiring diagram for humidifier using VisionPROIAQ

HUMIDIFIER

MECHANICAL
HUMIDISTAT

120 VAC

TO BLOWER
MOTOR
IGNITION BOX

M12686A

YELLOW WIRES

1

1

2

2

POWER SUPPLY.  PROVIDE DISCONNECT MEANS AND 
OVERLOAD PROTECTION AS REQUIRED.

24V WIRING.

CURRENT
SENSING
RELAY

HUMIDIFIER

120 VAC

BLOWER 
MOTOR

C

LO

HI

M12684A

YELLOW WIRES

1

1

2

2

POWER SUPPLY.  
PROVIDE DISCONNECT
MEANS AND OVERLOAD 
PROTECTION AS REQUIRED.

24V WIRING.

MECHANICAL
HUMIDISTAT

SAIL 
SWITCH

HUMIDIFIER

120 VAC

M12685A

YELLOW WIRES

1

1

2

2

POWER SUPPLY.  PROVIDE DISCONNECT
MEANS AND OVERLOAD PROTECTION 
AS REQUIRED.

24V WIRING.

MECHANICAL
HUMIDISTAT

HVAC

TrueIAQ

THERMOSTAT

HUM    
HUM    

R
C

W
G

G

Y

W

R

Rc

G

Y

W

R

C

YELLOW   

required to isolate the G wire.

TH8320 or TH8321 is used, a relay may be

TH5320, TH6110, TH6220, TH6320, TH8110, 

If a thermostat other than TH5110, TH5220, 

1

1

M31027    

Yellow

HUM

1 Set VisionPRO IAQ ISU #372 and #374 to 

control for frost and HVAC fan operation.

M30128