24
Installation and Setup
Figure 2-6
Alarm Output Connection
The alarm output can be configured to provide normally open or normally closed contacts
(see
to configure the alarm output). Contacts will be rated for
12 V DC @ 0.5 A.
Connecting Audio
The network camera supports bi-directional audio. There are two supported voice band
channels that function in full duplex mode. The camera can transmit audio from the camera
to the client (PC) using any audio source that provides an industry standard line level input
(3.5 mm jack). The camera can also receive audio from the client (PC) and provide an
industry standard line level output (3.5 mm jack) suitable to connect to audio devices. Audio
input and output have 600 Ohm impedance. See
audio options.
Restoring Factory Defaults
Your network camera has a Factory Reset switch on the side of the camera (see
).
Use this switch to restore your camera options and passwords to their default settings. Use
a pin or straightened paper clip to press and hold the
Reset
switch for five seconds.
+
–
IN
OUT
IN
OUT
ALARM
In
Out
+
–
Summary of Contents for HCD5HIH