User Guide
Galaxy 2-44
Honeywell Security
www.PDF-Zoo.com
Page 1: ...User Guide Galaxy 2 44 Honeywell Security www PDF Zoo com ...
Page 2: ......
Page 3: ...d Unsetting Groups 6 Setting and Unsetting Without Group Choice 6 Setting and Unsetting With Group Choice 6 Menu Access 7 Menu 11 Omit 8 Menu 12 Timed Set 8 Menu 13 Part Set 8 Menu 14 Night Set 8 Menu 15 Chime 8 Menu 21 Zone Status 8 Menu 22 View Log 9 Menu 23 Display Version 9 Menu 24 Print 9 Menu 31 Walk Test 10 Menu 32 Output Test 10 Menu 41 Time Date 10 Menu 42 Editing Users 10 Menu 44 Mobile ...
Page 4: ...iv www PDF Zoo com ...
Page 5: ...configuration in order to continue to provide the best protection whilst maintaining ease of use An alarm system will protect you best only when used correctly Please take the time to read through these instructions carefully in order to get the best from your alarm system and avoid false alarms Remember An alarm system will only protect against intruders if it is Set appropriately Always remember...
Page 6: ...ess keyfob Although all of the above methods of control will allow the user to set and unset the system for day to day operation the keypad is required to reset the system after an alarm or fault condition The keypad is also used to access the menu structure where additional functions can be accessed such as Viewing the event log Programming user codes Temporarily omitting zones from the system Gr...
Page 7: ... a menu option The default user code is 1234 It is strongly recommended that this code is changed to some thing else as soon as possible Mk7 LCD Keypad 6160 Keypad Prox tags are devices that contain a microchip that has a unique serial number This number can be read by holding the tag in front of a prox reader Prox tags will allow you to set and unset the system only The prox readers are usually b...
Page 8: ...et the entire system Keypad Type your user code then press A Wireless Fob Press ON button Prox Tag Hold the tag in front of the PROX symbol for 3 seconds The exit timer will begin and there will be a constant tone Leave by the agreed exit route and close the door When the exit timer expires there will be a 5 second settle period and then two beeps will confirm the completion of setting If you hear...
Page 9: ... setting PART SET 030 Setting with Faults Normally if there is a fault of any kind on the system setting will not be permitted until the fault is rectified However depending on the set up of your system and the level of your user access it may be possible override a fault and proceed with the setting procedure If there are faults present when you try to set via the keypad the following typical dis...
Page 10: ...d display will show what has happened The scroll keys A and B should be used to scroll through the message screens If the condition has cleared pressing ent or esc will reset the fault condition A fault condition cannot be reset if it has not cleared or if it has not been viewed by a user If you cannot clear the fault condition yourself always call the installer for advice Setting and Unsetting Gr...
Page 11: ...ct Users can then navigate around the menu using the scroll keys ent key and esc key or they can jump to any specific menu item directly by typing the number of the item An overview of all the accessible function is shown below Not all users will be able to access all of the functions This will depend on their user type that is set up in menu 42 Table 1 Menu Access The function of each menu item i...
Page 12: ... Menu 14 Night Set This menu option initiates the timed night set routine as described earlier Menu 15 Chime This menu option allows one or more zones to be put into Chime mode When chime mode is enabled for a zone the internals sounders will beep twice each time the detector on that zone is activated This function can be useful for example in shop to indicate when a customer has come through the ...
Page 13: ... NOTE If groups are enabled you can select which groups to view before entering the log Menu 23 Display Version This menu option simply displays the software version number of the system Menu 24 Print This option allows system settings to be printed out if a printer is connected to the system If no printer is connected it has no effect On selecting the option there is a sub menu of 4 options which...
Page 14: ...r to save battery life during repeated activations Press the esc key to end the walk test All walk tested zones will be recorded in the event log Menu 32 Output Test This menu option allows the external bell and strobe to be tested There are two sub options which select between the bell and strobe Select the appropriate device and press ent This will go to the status display to show the current co...
Page 15: ...ss to Pressing the appropriate number key toggles the group on or off 4 Name This allows a 6 character label to be assigned to the user to aid identification when viewing the event log 5 RF Fob This allows a wireless keyfob to be assigned to the user The fob serial number is shown in the bottom row If a new fob is to be assigned it should be learned in as follows 1 Press the star key to start the ...
Page 16: ...y pressing ent 2 Message type This allows the kind of events that are sent to this mobile number There are 4 options 1 Alarm events Just sends alarm activations 2 Alarm set events Sends alarms and all set unset events 3 Alarm fault Sends all alarm events and fault conditions but not set unset events 4 All events Sends all of the above events as and when they occur Menu 47 Remote Access This menu o...
Page 17: ...P E L E T S R U O H E C I F F O S E M I T R E H T O O N T N U O C C A 0 0 O I R E N O Z N O I T C N U F N O I T P I R C S E D E M I H C T I M O T R A P 1 0 0 1 2 0 0 1 3 0 0 1 4 0 0 1 1 0 O I R 1 1 0 1 2 1 0 1 3 1 0 1 4 1 0 1 5 1 0 1 6 1 0 1 7 1 0 1 8 1 0 1 www PDF Zoo com ...
Page 18: ...14 IU1 0032 Rev B Copyright Honeywell Security www PDF Zoo com ...