background image

 

 
 

 
 
 
 
 
 
 
 
 
 
 

MS3780 Fusion

®

 

Omni/Single Line Scanner 

User’s Guide 

 
 
 

Summary of Contents for Fusion MS3780

Page 1: ...MS3780 Fusion Omni Single Line Scanner User s Guide ...

Page 2: ...ected by copyright All rights reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII 2004 2010 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Trademarks Metrologic QuantumE CodeGate MetroSelect and MetroSet2 are trademarks or registered trademarks of Metrologic Instruments Inc o...

Page 3: ...485 or OCIA 8 Keyboard Wedge 9 Stand Alone Keyboard Wedge 10 Full Speed or Low Speed USB Integrated 11 EAS Deactivation 12 Scanner Operation The Scan Pattern Mode Select Button 13 How to Use CodeGate and the Manual Activation Mode 14 Indicators Audible 15 Visual 16 Failure 17 Depth of Field Specifications Normal Scan Zone 18 Reduced Scan Zone 19 Depth of Field by Bar Code Element Width Normal Scan...

Page 4: ...cations 27 Applications and Protocols 29 Configuration Modes 30 Upgrading the Firmware 31 Scanner and Cable Terminations 32 Regulatory Compliance 36 Limited Warranty 39 Patents 41 Index 42 Customer Support 44 Technical Assistance 44 Product Service and Repair 45 ...

Page 5: ...nfigurable Depth of Field Easy Bar Code Configuration Data Editing 7 Beeper Tones Firmware updates are easily loaded into Flash memory OPOS and JPOS System Compatible CodeGate Sunrise 2005 Compliant SCANNER INTERFACE MS3780 9 OCIA and RS232 Transmit Receive MS3780 11 RS485 and Full RS232 MS3780 38 RS232 Low Speed USB Keyboard Emulation Mode or USB Serial Emulation Mode MS3780 40 Full Speed USB MS3...

Page 6: ...00528 90VAC 255VAC Australia 46 00529 90VAC 255VAC China 46 00530 90VAC 255VAC India The following cables are for Fusion models not equipped with EAS 53 53000x 3 RS232 PowerLink Cable with Built in Power Jack coiled cord long strain relief black 53 53002x 3 Keyboard Wedge PowerLink cable with Adapter Cable coiled cord long strain relief black 53 53020x 3 Stand Alone Keyboard PowerLink Cable coiled...

Page 7: ...Connector straight cord short strain relief The following cables are for Fusion models equipped with EAS 59 59000x E 3 RS232 PowerLink Cable with Built in Power Jack and EAS Connection Wire long strain relief straight cable black 59 59006x E 3 RS485 PowerLink Cable with Built in Power Jack and EAS Connection Wire long strain relief straight cable black 55 55809x N E 3 USB Keyed Type A EAS Connecti...

Page 8: ...de Select Button See page 13 3 Beeper See page 15 4 Blue LED Single Line Mode Menu Reading See page 15 5 White LED See page 15 6 Blue LED All Scan Lines On Omnidirectional Reading See page 15 7 Amber LED CodeGate See page 15 8 CodeGate Button See page 14 9 Pin Hole for Cable Release See page 6 10 10 Pin RJ45 Female Socket See page 32 ...

Page 9: ...ts connected to the scanner must meet the requirements for SELV Safety Extra Low Voltage according to EN IEC 60950 1 To maintain compliance with standard CSA C22 2 No 60950 1 UL 60950 1 and norm EN IEC 60950 1 the power source should meet applicable performance requirements for a limited power source Stand Specifications Figure 3 Stand Specifications ...

Page 10: ...nit s exterior Cable Removal Disconnect the power supply from the PowerLink cable and turn off power to the host system before removing the cable from the scanner 1 Locate the small pin hole beneath the Fusion logo on the front side of the scanner near the end of the handle 2 Bend an ordinary paperclip into the shape shown in figure 4 3 Insert the paperclip or other small metallic pin into the sma...

Page 11: ...power supply to make sure the voltage matches the AC outlet The outlet must be located near the equipment and be easily accessible 5 Connect AC power to the transformer 6 Turn on the host device When the scanner first receives power the white LED will flash one blue LED will turn on and the scanner will emit one beep Plugging the scanner into the serial port of the PC does not guarantee that scann...

Page 12: ...ion port on the host device 4 Turn on the host device When the scanner first receives power the white LED will flash one blue LED will turn on and the scanner will emit one beep Plugging the scanner into the serial port of the PC does not guarantee that scanned information will appear at the PC A software driver and correct configuration setting are also required for proper communication to occur ...

Page 13: ...the power supply to make sure the voltage matches the AC outlet The outlet must be located near the equipment and be easily accessible 6 Connect AC power to the transformer 7 Turn on the host device When the scanner first receives power the white LED will flash one blue LED will turn on and the scanner will emit one beep Powering the MS3780 directly from the host device can sometimes cause interfe...

Page 14: ...t must be located near the equipment and be easily accessible 5 Connect AC power to the transformer 6 Turn on the host device When the scanner first receives power the white LED will flash one blue LED will turn on and the scanner will emit one beep Powering the MS3780 directly from the host device can sometimes cause interference with the operation of the scanner or the computer Not all computers...

Page 15: ...ation Mode enabled For information on configuring the MS3780 38 for USB Serial Emulation Mode please refer to the USB Low Speed section of the MetroSelect Configuration Guide MLPN 00 02407 When the scanner first receives power the white LED will flash one blue LED will turn on and the scanner will emit one beep Plugging the scanner into the USB port of the PC does not guarantee that scanned inform...

Page 16: ... OFF Checkpoint Recommended Switch Bank Settings For USB SW1 SW2 Switch 1 ON Switch 1 ON Switch 2 3 4 5 and 6 OFF Switch 2 3 4 5 and 6 OFF All Fusion models equipped with EAS capabilities have an EAS designation in their model numbers The cable supplied with these units will have additional wires for connection to the Checkpoint Device Figure 12 EAS Cable Figure 13 shows the location of the EAS de...

Page 17: ...nu reading Please refer to the MetroSelect Configuration Guide for information on changing the default scan pattern settings To Change Scan Pattern Modes 1 To activate the secondary scan pattern press and release the mode select button Press and Release the Mode Select Button Pattern Mode LED Switches to New Active Pattern Figure 14 Figure 15 Activating a pattern mode when the scanner is out of it...

Page 18: ...ATION MODE This feature is not a default setting Refer to the MetroSelect Configuration Guide for instructions on enabling the Manual Activation Mode Figure 16 Figure 17 Factory Defaults In Stand CodeGate is not active Amber LED is On Out of Stand CodeGate is active Amber LED is Off For information on how to change the factory defaults refer to the MetroSelect Configuration Guide 00 02407 ...

Page 19: ...the white light does not flash then the bar code has not been successfully read Razzberry Tone This is a failure indicator Refer to Failure Mode Indicators on page 17 Three Beeps during operation When placing the scanner in configuration mode the white and blue LEDs will flash while the scanner emits three beeps The white and blue LEDs will continue to flash until the unit exits the configuration ...

Page 20: ... illuminated until the laser is deactivated Steady Blue Single Line or Omni LED and a Single White LED Flash When the scanner successfully reads a bar code the white LED will flash and the scanner will beep once If the white LED does not flash or the scanner does not beep then the bar code has not been successfully read Steady White and Blue Single Line or Omni LED After a successful scan the scan...

Page 21: ...is indicates that the scanner has experienced a motor failure Return the unit to a Honeywell authorized service center for repair Continuous Razzberry Tone with Both LEDs Off On Power Up A continuous razzberry tone upon power up indicates there has been an electronic failure Return the unit to a Honeywell authorized service center for repair Three Beeps On Power Up This indicates that the nonvolat...

Page 22: ...CANNER OPERATION Depth of Field Specifications Normal Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Figure 19 Normal Depth of Field All specifications are subject to change without notice ...

Page 23: ...ANNER OPERATION Depth of Field Specifications Reduced Scan Zone Specifications are based on a 0 33 mm 13 mil bar code Figure 20 Reduced Depth of Field All specifications are subject to change without notice ...

Page 24: ... Bar Code Element Width Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm 13 15 19 25 33 66 mils 5 2 5 7 7 5 10 13 26 Figure 21 Normal Scan Zone by Bar Code Element Width All specifications are subject to change without notice ...

Page 25: ...Bar Code Element Width Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm 13 15 19 25 33 66 mils 5 2 5 7 7 5 10 13 26 Figure 22 Reduced Scan Zone by Bar Code Element Width All specifications are subject to change without notice ...

Page 26: ...se Any movement detected by the IR in the activation area will cause the scanner to exit power save mode The laser and motor will automatically turn back on preparing the scanner for bar code recognition decoding and transmission Figure 23 Normal IR Activation Range All specifications are subject to change without notice Refer to the MetroSelect Configuration Guide MLPN 00 02407 for additional inf...

Page 27: ...ans upon presentation of code The same symbol timeout is set too short Adjust the same symbol timeout for a longer time increment The unit powers up but does not beep The beeper is disabled Enable the beeper No tone is selected Select a tone The unit powers up but does not scan and or beep The unit is trying to scan a particular symbology that is not enabled UPC EAN Code 39 Interleaved 2 of 5 Code...

Page 28: ...to the host is incorrect The scanner s data format does not match the host system requirements Verify that the scanner s data format matches the format required by the host Make sure that the scanner is connected to the proper host port Scanner beeps at some bar codes and NOT for others of the same bar code symbology The bar code may have been printed incorrectly Check if it is a check digit chara...

Page 29: ...s a VLD failure Contact a service representative During power up the unit razzes twice and both LEDs flash There is a scanner motor failure Contact a service representative RS232 Only The unit powers up OK and scans OK but does not communicate properly to the host The com port at the host is not working or is not configured properly Check to make sure that the baud rate and parity of the scanner a...

Page 30: ...configured for the appropriate mode The unit scans but the data is not correct The unit may not be configured correctly Make sure that the proper PC type ie AT PS2 or XT is selected Verify correct country code and data formatting are selected Adjust the intercharacter delay The unit is not transmitting each character The unit may not be configured correctly Increase the interscan code delay settin...

Page 31: ... Wedge Stand Alone Keyboard Light Pen Emulation RS485 USB low speed and full speed OCIA Print Contrast 35 minimum reflectance difference No Characters Read Up to 80 data characters Maximum number will vary based on symbology and density Beeper Operation 7 tones or no beep Indicators LED Blue laser on ready to scan White good read decoding Termination 10 position modular RJ45 connector Cable Applic...

Page 32: ...ss II 5 2VDC 1A For regulatory compliance information see pages 36 38 Environmental Operating Temperature 20 C to 40 C 4 F to 104 F Storage Temperature 40 C to 60 C 40 F to 140 F Humidity 5 to 95 relative humidity non condensing Contaminants Sealed to resist airborne particulate contaminants Ventilation None required Shock Withstands multiple drops from 1 5 meters Specifications subject to change ...

Page 33: ...pplications The MS3780 scanner with Built in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only Many RS232 configurable functions e g formatting available in other Honeywell scanners are also available as keyboard wedge functions The following are the most important selectable options specific to the keyboard wedge Keyboard Type AT includes IBM PS2 models 50 55 60 80 IB...

Page 34: ...This user friendly Windows based configuration program allows you to simply point and click at the desired imager options MetroSet2 is available for download at www honeywellaidc com Serial Programming This mode of configuration is ideal for OEM applications Serial programming mode gives the end user the ability to send a series of commands using the serial port of the host system The commands are...

Page 35: ... firmware in the MS3780 1 Plug the scanner into a serial communication port on the host system 2 Start the MetroSet2 software 3 Click on the plus sign next to POS Scanners to expand the supported scanner list 4 Choose the Fusion from the list 5 Click on the Configure Fusion 3780 Scanner button 6 Choose Flash Utility from the options list located on the left side of the screen 7 Click on the Open F...

Page 36: ...tput 2 RS232 Transmit Output 3 RS232 Receive Input 3 RS232 Receive Input 4 PC Data 4 RTS Output 5 PC Clock 5 CTS Input 6 KB Clock 6 DTR Input LTPN Source 7 PC 5V 7 Reserved 8 KB Data 8 LTPN Data 9 5VDC 9 5VDC 10 Shield Ground 10 Shield Ground MS3780 40 Full Speed USB MS3780 38 RS232 Low Speed USB Pin Function Pin Function 1 Ground USB 1 Ground USB 2 RS232 Transmit Output 2 RS232 Transmit Output 3 ...

Page 37: ...e Input 4 RTS Output 4 RDATA 5 CTS Input 5 RDATA Return 6 DTR Input 6 Clock In 7 IBM B Transmit 7 Clock Out 8 IBM A Receive 8 Clock in Return Clock out Rtrn 9 5VDC 9 5VDC 10 Shield Ground 10 Shield Ground MS3780 120 USB and RS232 with EAS Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 EAS 5 EAS 6 USB D 7 USB V 8 USB D 9 5VDC 10 Shield Ground Applicable for IBM Host applicati...

Page 38: ...6 Light Pen Data 7 CTS Input 8 RTS Output 9 5VDC USB Power Communication Cable 53 53213x N 3 53 530214x N 3 or 53 53235x N 3 Pin Function 1 PC 5V V_USB 2 D 3 D 4 Ground Shield Shield Stand Alone Keyboard PowerLink Cable 53 53020x 3 Pin Function 6 Pin Male Mini DIN Connector 1 PC Data 2 No Connect 3 Power Ground 4 5VDC PC Power to KB 5 PC Clock 6 No Connect 9 Pin D Type Connector 9 5 6 1 USB Type A...

Page 39: ...r cable with a 5 pin DIN male connector on one end and a 6 pin mini DIN female connector on the other According to the termination required connect the appropriate end of the adapter cable to the PowerLink cable leaving the necessary termination exposed for connecting to the keyboard and the keyboard port on the PC Keyboard Wedge Adapter Cable Pin Function 5 Pin DIN Male 1 PC Clock 2 PC Data 3 No ...

Page 40: ...ions Le client ne doit en aucun cas essayer d entretenir lui même le scanner ou le laser Ne regardez jamais directement le rayon laser même si vous croyez que le scanner est inactif N ouvrez jamais le scanner pour regarder dans l appareil Ce faisant vous vous exposez à une rayonnement laser qú êst hazardous L emploi d appareils optiques avec cet équipement laser augmente le risque d endommagement ...

Page 41: ...lled and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense Any unauthorized changes or modifications to this equipment could void the user s authority to operate this de...

Page 42: ...terference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy an...

Page 43: ...ng HII In the event that the product is returned to HII or its authorized service center within the Warranty Period and HII determines to its satisfaction that the product is defective due to defects in materials or workmanship HII at its sole option will either repair or replace the product without charge except for return shipping to HII EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW THE ...

Page 44: ...of Use of any peripherals not provided by the manufacturer may result in damage not covered by this warranty This includes but is not limited to cables power supplies cradles and docking stations HII extends these warranties only to the first end users of the products These warranties are non transferable The duration of the limited warranty for the MS3780 is three 3 year s The accessories have a ...

Page 45: ...41 PATENTS For patent information please refer to www honeywellaidc com patents ...

Page 46: ...23 26 29 Compliance 7 11 36 37 Components 2 4 Configuration 15 17 30 31 Current 28 D DC 2 28 Default Settings 13 29 Depth of Field Normal 18 20 27 Reduced 19 20 21 27 E EAS 12 EMC 37 EMI 37 Emissions 37 F Failure Modes 17 Firmware 31 Flash ROM 1 H Host 23 26 I Immunity 37 Indicator Audible 4 15 17 23 26 27 31 Failure 17 Visual 4 15 17 23 26 27 31 Interface 27 Keyboard Wedge 1 9 26 Laser Emulation ...

Page 47: ...ry Tone 15 17 25 Read Rate 14 Repair 17 ROM 25 RS232 7 25 26 RS485 8 S Safety 36 38 Scan Lines 27 Scan Pattern 1 27 Primary 13 14 Secondary 13 14 Single Line 13 14 Scan Speed 27 SELV 7 11 Single Line Mode 4 Specification Electrical 28 Environmental 28 Mechanical 27 Operational 27 Stand Alone Keyboard 10 Storage 28 Switch Bank 12 T Tone 1 15 Transformer 2 28 Troubleshooting 23 26 U Upgrade 31 USB 1...

Page 48: ...co Telephone 01 800 HONEYWELL 01 800 466 3993 E mail soporte hsm honeywell com Europe Middle East and Africa Telephone 31 0 40 7999 393 Fax 31 0 40 2425 672 E mail hsmeurosupport honeywell com Hong Kong Telephone 852 29536436 Fax 852 2511 3557 E mail aptechsupport honeywell com Singapore Telephone 65 6842 7155 Fax 65 6842 7166 E mail aptechsupport honeywell com China Telephone 86 800 828 2803 Fax ...

Page 49: ...263 9689 E mail laservice honeywell com Brazil Telephone 55 11 5185 8222 Fax 55 11 5185 8225 E mail brservice honeywell com Mexico Telephone 01 800 HONEYWELL 01 800 466 3993 Fax 52 55 5531 3672 E mail mxservice honeywell com Europe Middle East and Africa Telephone 31 0 40 2901 633 Fax 31 0 40 2901 631 E mail euroservice honeywell com Hong Kong Telephone 852 29536436 Fax 852 2511 3557 E mail apserv...

Page 50: ...46 CUSTOMER SUPPORT Online Product Service and Repair Assistance You can also access product service and repair assistance online at www honeywellaidc com ...

Page 51: ......

Page 52: ...Honeywell Scanning and Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 00 02269 Rev F 11 10 ...

Reviews: