Table 1. Operating Specifications

Characteristic

Analog

Digital

Unit

Min. 

Typ.

Max.

Min. 

Typ.

Max.

Supply voltage (V

supply

):

1, 2, 3

   3.3 Vdc
   5.0 Vdc

3.0

4.75

3.3
5.0

3.6

5.25

3.0

4.75

3.3
5.0

3.6

5.25

Vdc

Supply current:
   3.3 Vdc
   5.0 Vdc  


2.0
2.6



2.8
3.9

3.9
4.6

mA

Power input

13

20

mW

Operating temperature range

4

0 [32]

70 [158]

0 [32]

70 [158]

°C [°F]

Compensated temperature range

5

5 [41]

50 [122]

5 [41]

50 [122]

°C [°F]

Storage temperature range

-40 [-40]

85 [185]

-40 [-40]

85 [185]

°C [°F]

Startup time (power up to data ready)

5

3

ms

Response time

1

0.42

0.84

ms

Clipping limit:
   upper
   lower

2.5


97.5




%V

supply

SPI/I

2

C voltage level:

   low
   high




80


20

%V

supply

Pull up on SDA/MISO, SCL/SCLK, SS

1

kOhm

Accuracy

6

±3

±3

%FSS

7

 BFSL

Total Error Band

8

±5

±5

%FSS

Output resolution

12

bits

Long term stability

9

 

±1.3

±1.3

%FSS

1

Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.

2

Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.

3

The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.

4

Operating temperature range: The temperature range over which the sensor will produce an output proportional to force. 

5

Compensated temperature range: The temperature range over which the sensor will produce an output proportional to force within the specified 

performance limits.

6

Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the force range at 25°C [77°F]. 

Includes all errors due to force non-linearity, force hysteresis, and non-repeatability.

7

Full Scale Span (FSS): The algebraic difference between the output voltage at full scale force and the output at zero force.

8

Total Error Band (TEB): Combined error from calibration, accuracy and temperature effects over the compensated temperature range at 5.0 V from 

15 %FSS to 95 %FSS.

9

Long-term stability after 1000 hr of operation at 25°C [77°F].

Summary of Contents for FSA Series

Page 1: ...listing selected 2 Ratiometricity of the sensor the ability of the device output to scale to the supply voltage is achieved within the specified operating voltage 3 The sensor is not reverse polarity protected Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure 4 Operating temperature range The temperature range over which the sensor will produce an outp...

Page 2: ...to 95 RH non condensing Vibration MIL STD 202 Method 214 Condition 1E 16 9 G Shock MIL STD 202 Method 213 Condition F 1500 G Life1 1 million full scale force cycles minimum 1 Life may vary depending on specific application in which the sensor is utilized Table 4 Absolute Maximum Specifications Characteristic Min Max Unit Supply voltage 0 3 6 0 Vdc Voltage on any pin 0 3 Vsupply 0 3 V Digital inter...

Page 3: ...nsfer function options 0 10 20 30 40 50 60 70 80 90 100 1 2 3 4 5 6 7 8 9 10 5 Total Error Band 0 Fmin Fmax Compensated Force Range Force example unit Output Vsupply 0 8 x Vsupply Output V x Force applied 0 10 x Vsupply Ideal Force range 80 Output of 214 counts x Force applied 10 Force range 0 10 20 30 40 50 60 70 80 90 100 1 2 3 4 5 6 7 8 9 10 5 Total Error Band 0 Fmin Fmax Compensated Force Rang...

Page 4: ...2 19 0 48 5 7 0 22 3 68 0 14 17 36 0 68 7 1 0 28 8 25 0 32 3X 1 31 0 05 2X 3 94 0 15 3X 0 61 0 02 Pin 1 ø12 70 0 5 Plunger 17 36 0 68 25 02 0 99 23 57 0 93 1 79 0 07 5 7 0 22 3 68 0 14 12 19 0 48 7 1 0 28 8 25 0 32 5X 1 31 0 05 2X 3 94 0 15 5X 0 61 0 02 5X 6 48 0 26 3 57 0 14 5 74 0 23 5X 0 63 0 02 4X 2 54 0 1 ø12 70 0 5 Pin 1 Plunger Function Pin 1 Pin 2 Pin 3 analog Vsupply Vout GND Function Pin...

Page 5: ...iterature and the Honeywell web site it is buyer s sole responsibility to determine the suitability of the product in the application Specifications may change without notice The information we supply is believed to be accurate and reliable as of this writing However Honeywell assumes no responsibility for its use WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop device...