Table 1. Operating Specifications
Characteristic
Analog
Digital
Unit
Min.
Typ.
Max.
Min.
Typ.
Max.
Supply voltage (V
supply
):
1, 2, 3
3.3 Vdc
5.0 Vdc
3.0
4.75
3.3
5.0
3.6
5.25
3.0
4.75
3.3
5.0
3.6
5.25
Vdc
Supply current:
3.3 Vdc
5.0 Vdc
—
—
2.0
2.6
—
—
—
—
2.8
3.9
3.9
4.6
mA
Power input
13
20
mW
Operating temperature range
4
0 [32]
—
70 [158]
0 [32]
—
70 [158]
°C [°F]
Compensated temperature range
5
5 [41]
—
50 [122]
5 [41]
—
50 [122]
°C [°F]
Storage temperature range
-40 [-40]
—
85 [185]
-40 [-40]
—
85 [185]
°C [°F]
Startup time (power up to data ready)
—
—
5
—
—
3
ms
Response time
—
1
—
—
0.42
0.84
ms
Clipping limit:
upper
lower
—
2.5
—
—
97.5
—
—
—
—
—
—
—
%V
supply
SPI/I
2
C voltage level:
low
high
—
—
—
—
—
—
—
80
—
—
20
—
%V
supply
Pull up on SDA/MISO, SCL/SCLK, SS
—
—
—
1
—
—
kOhm
Accuracy
6
—
—
±3
—
—
±3
%FSS
7
BFSL
Total Error Band
8
—
—
±5
—
—
±5
%FSS
Output resolution
—
—
—
12
—
—
bits
Long term stability
9
—
±1.3
—
—
±1.3
—
%FSS
1
Sensors are either 3.3 Vdc or 5.0 Vdc based on the catalog listing selected.
2
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
3
The sensor is not reverse polarity protected. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4
Operating temperature range: The temperature range over which the sensor will produce an output proportional to force.
5
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to force within the specified
performance limits.
6
Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the force range at 25°C [77°F].
Includes all errors due to force non-linearity, force hysteresis, and non-repeatability.
7
Full Scale Span (FSS): The algebraic difference between the output voltage at full scale force and the output at zero force.
8
Total Error Band (TEB): Combined error from calibration, accuracy and temperature effects over the compensated temperature range at 5.0 V from
15 %FSS to 95 %FSS.
9
Long-term stability after 1000 hr of operation at 25°C [77°F].