5
I
NSTALLATION
Cable to Access Point Connection
1. Align the tab on the modular connector with the pinhole on the access point
device (see figure below).
2. Insert the modular connector into the device’s socket.
3. Test the cable’s connection to ensure the connector lock has engaged.
Important: If the cable is not fully latched, the unit can power intermittently.
4. Refer to pages 5 – 6 for the appropriate host connections applicable to the
interface type.
Figure 5. Cable Installation
RS232 Host Connections
1. Turn off power to the host system.
2. Connect the female, 9-Pin D-type
connector to a dedicated RS232
communication port on the host
system.
3. Plug
the
external power
supply into
the power jack on the PowerLink
cable.
Check the AC input requirements of the power supply verify the
voltage matches the AC outlet. The outlet must be located near the
equipment.
See caution information on page 4.
4. Connect AC power to the transformer.
5. Turn on power to the host system.
Figure 6. RS232 Host Connections