Honeywell F115A1064 Product Data Download Page 3

MOUNTED MEDIA AIR CLEANERS

3

68-0201—05

Fig. 2. Choose location for air cleaners.

IMPORTANT

When selecting a location, make sure the air 
cleaner is secured to ceiling load-bearing supports 
or joists. If installing on a T-grid drop ceiling, 
secure the air cleaner to the true ceiling.

INSTALLATION

When Installing this Product…

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a hazard-
ous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable for 
your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

CAUTION

Electrical Shock Hazard.
Power source can shock.

• Do not connect the power source until after the 

air cleaner is mounted. This will prevent 
electrical shock or equipment damage.

• Be sure to turn off the air cleaner before 

servicing it.

• If the air cleaner must be turned on for an 

electrical check, be extremely cautious.

• Be cautious when working near the moving 

parts of the air cleaner.

DISCHARGE AIR FLOW IN ANY DIRECTION IS ACCEPTABLE.

1

1

MEDIA AIR

CLEANER

AIR SPACE

TO BE

CLEANED

M11694A

Summary of Contents for F115A1064

Page 1: ...Hospital grade filter 95 efficient at 0 3 micron MERV 16 F115 single speed models deliver up to 600 cfm 1020 m3 hr Select models include CPZ disposable canisters for odor control Light colored covers complement the ceiling finish Available in 120 Vac 60 Hz SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances There fore this unit may n...

Page 2: ... being switched on accidentally when servicing or cleaning the media air cleaner Choose Location The air cleaner is mounted horizontally and can be used in almost any air cleaning application For the most efficient operation centrally locate the air cleaner to the area to be cleaned For the best air patterns avoid discharging the air directly at an obstruction such as a ceiling beam decorative cor...

Page 3: ...o make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these instructions CAUTION Electrical Shock Hazard Power source can shock Do not connect the power source until after the air cleaner is mounted This will prevent electrical shock or equipment damage Be sur...

Page 4: ...plates 12 Replace the air cleaner cover OPERATION The F115 Ceiling Surface Mounted Media Air Cleaners provide their own air circulation When the air cleaner is powered the blower motor draws the contaminated air into the air cleaner Particles that are too small to be caught in the prefilter are removed by the particle or HEPA filter The cleaned air is then returned to the building space In areas w...

Page 5: ...e is a noticeable loss of air volume circulation approximately every 10 to 24 months 6 Reassemble the air cleaner and turn the power on PARTS LIST Refer to Table 2 and Fig 4 for a parts list and an exploded view of the parts Table 2 F115 Ceiling Surface Mounted Media Air Cleaner Parts List Fig Reference No Description Pack Qty Order Number 1 Blower Wheel 2 120V 60 Hz Single Speed Motor 3 Mid plate...

Page 6: ...MOUNTED MEDIA AIR CLEANERS 68 0201 05 6 Fig 4 Exploded view of F115 Ceiling Surface Mounted Media Air Cleaner components ACCESS PLATE INSPECTION PLATE PLENUM M12712B 8 1 2 3 4 5 6 7 ...

Page 7: ...MOUNTED MEDIA AIR CLEANERS 7 68 0201 05 ...