Installation and Commissioning

Instructions

Note: QuickSet Pro required for commissioning
 

 

 MR1500P / MR1500PF

Mid Range LightSpot

  

 

MR1500P

  

 

MR1500PF

Summary of Contents for Ex-Or MR1500P

Page 1: ...Installation and Commissioning Instructions Note QuickSet Pro required for commissioning MR1500P MR1500PF Mid Range LightSpot MR1500P MR1500PF ...

Page 2: ...not recommended for applications where there are large areas of metal e g metal ceiling or panelling as unpredictable sensitivity may result Also microwave presence detection is not completely attenuated by materials such as plasterboard wood and glass so the possibility of unwanted presence detection through office partitions should be considered when determining detector positioning and sensitiv...

Page 3: ...R1500Ps relay outputs may be connected in parallel provided the controlled load does not exceed 10Amps L L N 1 2 3 4 5 6 7 8 NC NC Mains Supply Always check product label before wiring Live Neutral Earth Live In Neutral Earth No Connection Live In Internally linked Volt Free Contacts or R R VOLT FREE OUTPUT L L N 1 2 3 4 5 6 7 8 NC NC Mains Supply Live Neutral Earth Live In Neutral Earth No Connec...

Page 4: ...e when the lights are OFF Choose setting from 10 to 100 where 10 10 of ON Sensitivity and 100 same as ON Sensitivity This is an approximation and should be tested on site during commissioning Like all programmable parameters the sensitivity settings will be retained in the event of a power failure and can be re programmed any number of times Factory Default Settings These are the settings to which...

Page 5: ...level read immediately before the download took place Tip Turn the lights off using the QuickSet Pro UTILITIES LightSpot_MLS LCM USER REMOTE to measure the perceived light level with no contribution from the controlled lighting Method 2 Teaching the Levels With the photocell configured asACTIVE or PASSIVE 1 If the lights are not already on switch them on manually by pressing HC5A or UTILITIES Ligh...

Page 6: ...6 ...

Page 7: ... detecting large movingmetalobjectswell beyondthe normalrangeat whichit is sensitiveto humantargets 3 This equipment switches lights no more frequently than would a responsible human occupant However manufacturersof some lightingtypes e g 2D luminaires may specifya maximumnumber of switchingcycles in order to achieve a predicted lamp life Please check with the manufacturer of the luminaires to ens...

Page 8: ...m RANGE Adjustable up to 20m OFF DELAY 1 min 96 hours plus 10 second walk test mode PHOTOCELL Passive Active Disabled adjustable 50 5000 lux MATERIAL Flame retardant PC ABS COLOUR White WEIGHT 180g semi flush version 160g surface version IP RATING 4X o o OPERATING TEMPERATURE 0 C to 40 C Contact Ex Or Technical Helpline on 01942 719229 for guidance on installation and commissioning W5103C Honeywel...