Configuring Camera Field of View Change Detection
The web client application can detect tampering of the camera field of view and show an
alarm message above the video display (see
Note
Before changing the current Scene Change settings, you must click
Reset
Scene
.
Note
Camera Field of View change detection works best detecting objects with sharp
edges and/or corners. Environments that are flat and/or monochrome might
trigger false alarms.
To detect a change in the camera field of view:
1.
Click the
Video Analytics
tab.
2.
In the
Scene Change Threshold
list, select one of the following options:
3.
Click
Apply
.
Note
To turn off camera field of view change detection, select
Disable
in the
Scene
Change Threshold
list.
Disable
is the default value.
Note
You must click
Apply
after you make changes to any settings to save those
changes. Settings are not saved unless you click
Apply
.
Table 4-14
Scene Change Threshold Values
Value
To detect …
High (80%)
Maximum change in the camera field of view. The alarm
message appears when there is at least an 80% change in
your camera field of view.
Medium (50%)
Medium change in the camera field of view. The alarm
message appears when there is at least a 50% change in
your camera field of view.
Low (30%)
Minimum change in the camera field of view. The alarm
message appears when there is at least a 30% change in
your camera field of view.