System (2)
4 - 21
Model 1010 Application Pack CB
Part No.: 4418024 - Rev. 1
Programming Manual
Constraints:
Baud rate is fixed to 9600 for NEXWATCH and
INTELLIGENT ADDITIVE.
Select one of the following options:
300
600
1200
2400
4800
9600*
19200
38400
Parity
Selects the parity for the communications interface.
Constraints:
Parity is fixed to None for NEXWATCH and
INTELLIGENT ADDITIVE.
Select one of the following options:
Odd*
Even
None
Stop Bits
Selects the number of stop bits for the communications interface.
Constraints:
Stop bits is fixed to One for NEXWATCH and
INTELLIGENT ADDITIVE.
Select one of the following options:
1*
2
Unit Address
Selects the unit address of the Port for computer communications.
Constraints:
Only if Comms Device = Computer
This address is not used if the port is assigned as
intelligent additive or NEXWATCH.
Enter a value in the following range:
1 to 31 (1*).
4.7.2 Terminal Automation Mode
Use this sub-menu to set the operating mode for terminal automation.
Terminal Automation
Mode
Selects whether the instrument will use load details as entered by the
operator, or request load details from the Terminal Automation System
(TAS).
Select one of the following options:
Standalone*