CM700 Wireless - Programmable Room Thermostat

1) Installation Information

As these products communicate using RF technology special care must be taken during installation. The 

location of the RF components as well as the building structure may influence performance of the RF 

system. To assure system reliability, please review and apply the information given below.

Within a typical residential building the two products should communicate reliably within a 30m range. It 

is important to take into consideration that walls and ceilings will reduce the RF signal. The strength of 

the RF signal reaching the relay box depends on the number of walls and ceilings separating it from the 

room thermostat, as well as the building construction - the diagram below illustrates an example of typical 

signal strength reduction. Walls and ceilings reinforced with steel or plasterboard walls lined with metal foil 

reduce the RF signal significantly more.

Once a position is selected for the room thermostat this can be checked using the RF Communication Test 

mode as described in section 

2.2.3 Locating the Room Thermostat

. If the position is unsuitable the relay 

box will not respond and an alternative position must be selected.

Typical example of Building Fabric Signal losses

Wall

Wall

Wall

Ceiling

Max. Signal Length 30 metres

= Signal Strength

Summary of Contents for CM721

Page 1: ...roducts from individual system packs are separated or mixed with other pre configured system packs during installations please refer to section 5 1 Binding Rebinding Procedure to bind the desired units together and allow them to communicate with each other Table of Contents Section Page 1 Installation Information 2 2 Installing the CM700 Wireless System 3 2 1 Installing the Relay box 3 2 2 Install...

Page 2: ... strength of the RF signal reaching the relay box depends on the number of walls and ceilings separating it from the room thermostat as well as the building construction the diagram below illustrates an example of typical signal strength reduction Walls and ceilings reinforced with steel or plasterboard walls lined with metal foil reduce the RF signal significantly more Once a position is selected...

Page 3: ...iance considerations Keep AC mains supply load cables separate from signal wiring Refer to Code of Practice standards EN61000 5 1 and 2 for guidance NOTE The Relay Box contains no user serviceable parts It should be opened and installed by qualified installer only WARNING Electrostatic sensi tive device Do not touch the circuit board NOTE All wiring must be in accordance with IEE regulations CAUTI...

Page 4: ...the green button to confirm c Press the or buttons to set the current year e g yr 07 2007 then press the green button to confirm The date is now stored d Use the or buttons to set the correct time then press the green button to confirm Each press of the buttons will change the time by one minute and holding them down will change the time slowly at first and get progressively quicker Note If this m...

Page 5: ...djust the setpoint up to the maximum 35 C by pressing the button The boiler should come on green LED ON on relay box after a few seconds and the symbol appears on the room thermostat LCD display 5 Press the OFF button The boiler will go off green LED OFF on relay box after a few seconds and the symbol disappears 6 Check the system operation by alternately pressing the MAN and OFF buttons several t...

Page 6: ...iod of 1 hour the red LED will illuminate to indicate that no RF messages have been received during the last hour The relay box will also enter the failsafe mode as selected in Installer Mode see section 4 2 BDR91 Relay box Fail Safe Mode Setup To allow manual control of the relay box output manual override is available in fail safe mode When RF communication is restored the relay box will automat...

Page 7: ...o indicate the selected fail safe mode IMPORTANT To enable the frost protection when RF communication is lost select the fail safe mode 1 For systems with separate frost protection thermostat or where frost protection is not required select fail safe mode 0 1 Press the OFF button 2 Press and hold the button and the two PROGRAM and buttons together 3 The unit will display the first parameter of ins...

Page 8: ...e preset period expires the CM721 CM727 will display the SERVICE icon Set parameter 19 SP to the required value to enable maintenance alert Value set to zero disables the function Summer Winter Auto time change This feature moves time automatically on the last Sunday of March and the last Sunday of October The feature is factory enabled To enable Set parameter 3 tC category 1 to 1 Temperature Offs...

Page 9: ...1 Auto Summer Winter Time Change Enabled 0 Auto Summer Winter Time Change Disabled LCD Backlighting 5 bL 1 Backlighting Enable 0 Backlighting Disabled Upper Temp Limit 6 uL 35 35 C Upper Temp Limit 21 to 34 21 C to 34 C adjustment in 1 C steps Lower Temp Limit 7 LL 5 5 C Lower Temp Limit 5 to 21 6 C to 21 C adjustment in 1 C steps Optimisation 8 OP 0 Optimisation Disabled 1 Optimisation Enabled Te...

Page 10: ...tton on the room thermostat Then press the and buttons together along with the button The unit will display InSt and CONTROL BINDING 5 Press the green button to send the binding signal out to the relay box The red LED is switched off to confirm successful binding operation If the red LED still flashes push the button again until binding is successful 6 Now go to Section 2 Installing the CM700 Wire...

Page 11: ...correct or incomplete binding procedure Incorrect position of the room thermostat during binding Repeat the binding procedure Repeat the binding procedure keeping approx 1 m distance between the relay box and the room thermostat The red LED on the relay box is illuminated Communication loss The relay box receives no RF messages from the room thermostat RF signal is blocked due to wrong location of...

Page 12: ...and by its Authorised Representative Honeywell International Inc Honeywell Control Systems Ltd Arlington Business Park Bracknell Berkshire RG12 1EB Technical Help Desk 08457 678999 www honeywelluk com Hereby Honeywell declares that this CM727 CM721 room thermostat and BDR91 Relay Box are in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC 2006 95 EC a...

Reviews: