 USER GUIDE

The Chronotherm Modulation is designed to provide automatic time and
temperature control of heating systems. These instructions explain how to
program and operate your Chronotherm Modulation.

Chronotherm Modulation can be used with all 

OpenTherm

®

 compatible boilers.

The 

OpenTherm

®

 compatible boilers are marked with OT logo shown below.

Chronotherm Modulation is a programmable thermostat that controls your heating
system so that you can have comfortable temperatures when you are at home and
energy savings when you are out. To ensure that your heating system is operating
in most efficient way Chronotherm Modulation not only switches the boiler on and
off but also modulates the flame to finely match the heating output of the heating
appliance to the current heat demand.

To maximise energy efficiency Chronotherm Modulation has build -in Adaptive
Intelligent Recovery function Instead of switching the heating on at the set time
every day, the controller will delay the start time to the latest possible moment, so
that unnecessary heating is avoided. All you have to do is set the time by which
you want to be warm and Chronotherm Modulation will then decide when to turn
the heating on.

1

Day button allows you to set correct day of the week.

2

The display continuously shows information about time, day of the week and
temperature. The Energy meter allows you to see the current firing rate of the
boiler. A radiator or tap symbol is shown when boiler is servicing central
heating or domestic hot water.

3

These buttons are used to adjust the temperature level. You can operate
these buttons also when the flap is closed.

4

” Enquiry button is used to display the set room temperature level and the

outside temperature (only if the outside temperature sensor is connected to
your boiler).

5

The holiday function allows setting of a setback temperature for a period of
maximum 99 days. The same function can also be used  as timed program
override providing energy savings or extended comfort period.

6

These buttons are used to program up to six temperature changes per day.

7

Slider position defines the operating mode. When slider is set to AUTO the
Chronotherm will operate according to the program.

8

Time adjustment buttons are used for clock and temperature change
settings.

9

The copy button allows you to copy the time/temperature program to the next
day.

 SPECIAL FUNCTIONS

Modulating control

The Chronotherm Modulation continuously adapts the firing rate of the boiler to
the required heat demand. This results in a very accurate control of the room
temperature. The modulating control is only possible if the heating appliance is
supporting OpenTherm

®

 communications.

OpenTherm

®

 communication

The Chronotherm Modulation exchanges information with the heating appliance
using OpenTherm

®

 two-way communication protocol.

NOTE: The amount and type of information that can be displayed as well as
appliance specific information codes may vary.

Refer to the user manual of the appliance for this specific information.

Optimizing through the intelligent adaptive recovery (AIR) feature.

To achieve the required temperature in the house we typically set the on time for
the heating system earlier than required. In this way we can be sure that we will
have the comfortable temperature when we wake up. As we never can guess
precisely when the heating should come on we tend to stay on the save side
setting the on time earlier then required. Consequently we have to pay for keeping
the house at comfort temperature longer then necessary. The Chronotherm
Modulation solves this problem completely. It checks every day how much time is
required to heat up your home. Using this data the Chronotherm Modulation
calculates the precise moment when to start the heating up the next day to
achieve comfort temperature exactly when you want it. Consequently you do not
have to take the warm up time into account when programming. The Chronotherm
Modulation activates adaptive intelligent recovery function before every
programmed temperature level increase.

NOTE: After installation Chronotherm will require a couple of days to learn how to
calculate ON times for a particular house.

Program up to six time/temperature periods per day.

You have the possibility to set 6 different periods for each day of the week. The
time/temperature periods are marked with numbers 1 to 6.

The start time and temperature level for each period is programmable within the
temperature setting range of 5 to 30°C.

Backup during power supply failure

Your Chronotherm Modulation operates without batteries. The power is supplied
through the communication connection. In case of the mains power loss a
rechargeable backup power supply is sufficient to keep the program and the clock
settings for at least 8 hours. If the backup supply is exhausted the display will be
blank and the individual program will be deleted. After the mains supply has been
reestablished the factory program will be activated and the display will flash at
12.00. It will take between 10 and 60 minutes (dependant on the operating
conditions) to charge the backup supply.

The energy meter

If the burner of the boiler is energized, a bar of flames will be shown on the left
side of the display. This allows you to check at all times at what firing rate your
boiler is operating. (The percentages in the above graph are indicative only.
Dependant on the modulation band of your boiler the in between values may vary)

The radiator or tap symbol indicates if energy is being used for central heating or
the domestic hot water (if applicable).

Unique holiday/timer function

The holiday button allows you to override your normal temperature profile and set
the fixed temperature level for a defined time. You can set the required
temperature for as long as 99 days or as short as 1 hour.

Intelligent DHW control

If you own a boiler that also provides hot water (combi boiler) then the
Chronotherm Modulation can provide additional savings.

In the FROST PROTECTION or  HOLIDAY/TIMER function, the Chronotherm
Modulation will switch off the DHW function or (dependant of the appliance) will
switch to a savings mode. In this way the DHW storage will not be kept on a high
comfort temperature if this is not necessary.

If desired it is possible to switch off the DHW during the night setback period. Your
installer can set this for you.

NOTE: This function is only available if your boiler is suitable for this
communication. Consult the user manual of the boiler or ask your installer.

 CONTROLS LAYOUT

 PROGRAMMING YOUR THERMOSTAT

Before you start programming

You can program your Chronotherm Modulation only if the mains supply of the
boiler is switched on, the electrical connection to the boiler is made and the
thermostat has been mounted on the wall plate. When the power for the
thermostat is present the display will be activated and the clock will start.

NOTE: Operate the keypad with your fingertips only. Sharp objects like pens or
pencils can damage the keypad.

How do I set the time and the day?

1. Move the slider to 

DAY/

 position. The time and the

day marker will flash indicating that they can be
changed.

2. Press the 

 

+

 or 

 button until the correct time is

displayed. Each button press will change the time by
one minute and stop the display from flashing.
Holding the button down for a few seconds will
change the time slowly at first, then quickly.

3. Press 

DAY 1..7

 button until the day marker is

positioned under the correct day (

DAY1 

is Monday).

Each button press moves the day marker by one
day.

How do I get started with the built-in temperature program?

Move the slider to the 

AUTO

matic position

The Chronotherm Modulation will now control your heating system using the built-
in temperature program.

You now have a choice of two methods to set the program for the next day

6.a Press the 

COPY DAY

 button to copy Monday’s program into Tuesday. To set

several days of the week to the same program, press the copy day button
repeatedly.

6.b Press the 

DAY 1..7 

button to step the day marker to Tuesday (Day 2). The

program for Tuesday can be then set as described in steps 2 to 5.

Programs for Wednesday (Day 3) to Sunday (Day 7) can be set in the same
day, using the 

DAY 1..7 

button.

7.

Move the slider to 

AUTO

matic position when you have completed steps 6a or

6b. The Chronotherm Modulation will now control the room temperature to
match your program.

What do I do if I do not want to use all 6 temperature changes times?

The built-in program uses only 4 temperature change times as indicated in section

How do I get started with the built-in temperature program?

The unwanted change times can be deleted by moving the slider to 

PROGRAM

position and holding the appropriate button (1, 2, 3, 4, 5, 6) for a few seconds. The
change time will be removed and the display will show dashes instead of time/
temperature display.

Deleted temperature change times can be brought back by pressing the
appropriate (1, 2, 3, 4, 5, 6) button and then 

TEMP

erature 

 or 

 button (with

slider set to 

PROGRAM

 position).

 OPERATING YOUR THERMOSTAT

With the operating mode slider in 

AUTO

matic position Chronotherm Modulation

will control the room temperature to match your heating program

Manual Override

When the slider is in 

AUTO

matic position the temperature can be adjusted

temporarily by pressing the 

TEMP

erature 

 or 

 button. The temperature will

return to program at the next temperature change time.

How do I set the temperature for the whole day?

To operate as a simple thermostat with one temperature throughout the day, move
the slider to the 

MANUAL 

position. Adjust the manual temperature by pressing

the 

TEMP

erature 

 or 

 button. The manual temperature can be set anywhere

from 5°C up to 30°C.

How can I switch the Chronotherm Modulation off?

Move the slider to the 

 position. Thermostat has built-in frost protection feature,

so that if temperature will drop below 7°C it will automatically switch back on to
prevent pipes from freezing.

NOTE: The frost protection activation level can be adjusted from 7°C to 10°C
using 

TEMP

erature 

 or 

 button.

How do I check the programmed temperature?

In normal operation the temperature displayed is the actual room temperature. To
check the programmed temperature, press the i

 

button once.

NOTE: During upward temperature level change the temperature on the display
may not correspond with the programmed level of the current period. The reason
is that during warm up the thermostat gradually increases the temperature level
setting to the next temperature change level. During the warm up period the
number of the next period is flashing

How can I check the outside temperature?

Press the 

 button twice. The outside temperature code T3 will be displayed

together with current outside temperature value.

NOTE: This option is available only if the heating appliance provides the outside
temperature information to the thermostat.

I am going on holiday for a couple of weeks. How do I save energy when I
am away?

1. Move the slider to the operating position you require on returning from your

holiday (

AUTO

matic or 

MANUAL

)

2. Press the 

 (HOLIDAY) button to display the holiday days counter and the

temperature

3. Press the 

 + or – button to set the holiday time (1-99 days). An extra flashing

day marker shows the day of the week representing the holiday return day.
Today is counted as the first day of holiday. The holiday temperature is set
using the 

TEMP

erature 

 or 

 button. At midnight of the last day of your

holiday the thermostat will return to the normal control as set by the slider
position.

These two buttons can
also be used when the
flap is closed

Off

Low fire

40

60

80

100%

OpenTherm

®

 communication

Monday to Friday

Program 1

1

2

3

4

5

6

Time

07:00

09:00

-

-

19:00

23:00

Temperature

19°C

15°C

-

-

21°C

15°C

Saturdy and Sunday

Période

1

2

3

4

5

6

Time

08:00

-

-

-

-

23:00

Temperature

19°C

-

-

-

-

15°C

How do I set my own temperature program for each day of the week?

1. Move the slider to 

PROGRAM

 position. You will see

the first temperature change time and temperature
level for Monday’s program (the two small arrows
are displayed only when the programmed
temperature level is shown). The flashing display
indicates that you can make changes.

2. Press the 

 

+

 or 

 button to adjust the first

temperature change time. Holding the button down
will change the time quickly. The change time can
be set in 10 minutes steps from 03:00 in the
morning. The change time can be adjusted to any
time up to 02:50 on the next morning, so you can
maintain evening temperature after midnight.

NOTE: If you attempt to move a change time past
the next change time, both times will be moved.

3. Press the 

TEMP

erature 

 or 

 button to adjust the

first temperature level. Holding the button down will
change the temperature quickly. The temperature
can be set in 0.5°C steps from 5°C to 30°C

4. Press the program 2 button to display the second temperature change time and

temperature level for Monday. Set these by pressing the 

 + or – button and

the 

TEMP

erature 

 or 

 button.

5. The remaining temperature changes for Monday can be displayed by pressing

program buttons 3, 4, 5 and 6 and adjusted by using 

 + or – button and the

TEMP

erature 

 or 

 button. (if you don’t want to use all temperature change

times 2, 3, 4, 5 and 6 refer to the next question “

What if I don’t want to use all

6 time temperature change times

”)

 

 

 

Summary of Contents for Chronotherm modulation

Page 1: ...h you want to be warm and Chronotherm Modulation will then decide when to turn the heating on 1 Day button allows you to set correct day of the week 2 The display continuously shows information about time day of the week and temperature The Energy meter allows you to see the current firing rate of the boiler A radiator or tap symbol is shown when boiler is servicing central heating or domestic hot...

Page 2: ... numbers 1 to 6 The start time and temperature level for each period is programmable within the temperature setting range of 5 to 30 C Backup during power supply failure Your Chronotherm Modulation operates without batteries The power is supplied through the communication connection In case of the mains power loss a rechargeable backup power supply is sufficient to keep the program and the clock s...

Page 3: ...Sunday Période 1 2 3 4 5 6 Time 08 00 23 00 Temperature 19 C 15 C How do I set my own temperature program for each day of the week 1 Move the slider to PROGRAM position You will see the first temperature change time and temperature level for Monday s program the two small arrows are displayed only when the programmed temperature level is shown The flashing display indicates that you can make chang...

Page 4: ...he slider to the MANUAL position Adjust the manual temperature by pressing the TEMPerature or button The manual temperature can be set anywhere from 5 C up to 30 C How can I switch the Chronotherm Modulation off Move the slider to the position Thermostat has built in frost protection feature so that if temperature will drop below 7 C it will automatically switch back on to prevent pipes from freez...

Page 5: ...er position I m having some friends round for party How can I extend my heating program for a few hours 1 Press the HOLIDAY button twice to display the time when you would like to switch the heating off The time displayed is current time 1 hour rounded off to 30 minutes The return time can be adjusted using the or button in 30 minutes steps 2 Adjust your room temperature using TEMPerature or butto...

Page 6: ...hing it up This will loosen the thermostat from its wall plate 3 Always protect the contacts in the wall plate from paint or other substances IMPORTANT The wall plate terminals must not be connected to any other voltage sources Applying voltage to wall plate terminals can seriously damage your heating boiler Protect the electronic components from contact with any paint chemicals dust etc that coul...

Page 7: ...ram 1 2 3 4 5 6 Time _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Temperature _ _ C _ _ C _ _ C _ _ C _ _ C _ _ C THURSDAY Program 1 2 3 4 5 6 Time _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Temperature _ _ C _ _ C _ _ C _ _ C _ _ C _ _ C FRIDAY Program 1 2 3 4 5 6 Time _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ Temperature _ _ C _ _ C _ _ C _ _ C _ _ C _ _ C SATURDAY Program 1 2 3 4 ...

Page 8: ...the I you can read the fault code transmitted by the boiler The fault code depends on the boiler type refer to the boiler User Manual for more information TROUBLE SHOOTING GUIDE Chronotherm Modulation is able to provide you with fault diagnostic information Please note that the type of data sent from the boiler determines the way the boiler faults are displayed Review the boiler user manual for mo...

Reviews: