Resetting Gas Alarm Setpoints
Alarm setpoints are listed as defined by Occupational Safety and Health Association (OSHA).
Note: Standard factory alarm setpoints vary by region.
Sample Factory Alarm Setpoints
Gas
TWA
STEL
Low
High
O2
N/A
N/A
19.5% vol.
23.5% vol.
LEL
N/A
N/A
10% LEL
20% LEL
CO
35 ppm
50 ppm
35 ppm
200 ppm
H2S
10 ppm
15 ppm
10 ppm
15 ppm
Note: To disable an alarm, set the alarm setpoint to 0 (zero) in Safety Suite Device Configurator
(SSDC).
To change the factory-defined alarm setpoints, refer to See "Sensor Configuration" on