background image

User Guide

Y9420S Sundial RF

2

 Pack 3

How to use:

 

ST9420C Wireless Enabled Programmer

 

DT92E Wireless Room Thermostat

 

CS92A Wireless Cylinder Thermostat

 

BDR91T Wireless Enabled Relay Box (if installed)

System Components

Energy Efficiency and the Environment

Home energy use is responsible for more than ¼ of the total UK carbon emissions 

which contribute to climate change. Heating and hot water systems based on 

boilers account for   of this figure, so it is important to understand how your 

controls can help to maximize energy efficiency while maintaining your comfort.
Your Programmer should be used in conjunction with appropriate temperature 

controls. In order to save energy the following general points should be observed:
1.  Ensure your system contains a room thermostat and a hot water thermostat, 

and that both are set to appropriate temperature levels: typically 20°C for the 

room temperature and between 50 - 60°C for the hot water temperature.

2.  Programme your heating and hot water to be off when you are not in the house. If 

you are concerned about possible frost damage to any exposed pipe work, it is 

advisable to fit a frost protection system – your installer can advise you about this.

3.  Think about how you use your domestic hot water – if you have a storage 

system, it is not necessary to have this switched on all the time, even when you 

are in the house.

4. Consider the heat up times required for your central heating. Every home 

responds differently when the heating is switched on. Adjust the start time so 

that you are not cold when you get up in the morning. A shorter heat up time is 

required for other heating periods.

5.  In the evening, when the house is up to temperature, it is often possible to 

switch off the heating up to an hour before you go to bed, without any noticeable 

reduction in comfort.

This document is to be left with the user

and forms part of a Home Information Pack

This section is to be completed by the Installer

Honeywell Control Systems Ltd.

Arlington Business Park,
Bracknell
Berkshire
RG12 1EB
Technical Help Desk: 08457 678999
www.honeywelluk.com

50047645-008 A
© 2011 Honeywell International Inc.

PLEASE RESPECT YOUR ENVIRONMENT!

Take care to dispose of this product and any 

packaging or literature in an appropriate way

WHAT IS A PROGRAMMER?

...an Explanation for Householders (as recommended by the Energy Savings Trust)

Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central heating and 

domestic hot water on and off at the same time, while others allow the domestic hot water and heating to 

come on and go off at different times. Set the ‘On’ and ‘Off’ time periods to suit your own lifestyle. On some 

programmers you must also set whether you want the heating and hot water to run continuously, run under 

the chosen ‘On’ and ‘Off’ heating periods, or be permanently off. The time on the programmer must be 

correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean 

Time and British Summer Time. You may be able to temporarily adjust the 

heating programme, for example, ‘Override’, ‘Advance’, or ‘Boost’. These 

are explained in the manufacturer’s instructions. The heating will not work 

if the room thermostat has switched the heating off. And, if you have a hot-

water cylinder, the water heating will not work if the cylinder thermostat 

detects that the hot water has reached the correct temperature.

WHAT IS A ROOM THERMOSTAT?

...an explanation for Householders (as recommended by the Energy Savings Trust)

A room thermostat simply switches the heating system on and off as necessary. It works by sensing 

the air temperature, switching on the heating when the air temperature falls below the thermostat 

setting, and switching it off once this set temperature has been reached. Turning a room thermostat to 

a higher setting will not make the room heat up any faster. How quickly the room heats up depends on 

the design of the heating system, for example, the size of boiler and radiators. Neither does the setting 

affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the 

room being controlled at a lower temperature, and saves energy. The heating system will not work if 

a time switch or programmer has switched it off. The way to set and use your room thermostat is to 

find the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. 

The best way to do this is to set the room thermostat to a low temperature – say 18ºC – and then turn 

it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust 

the thermostat further. Any adjustment above this setting will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will usually be only one room thermostat to 

control the whole house. But you can have different temperatures in individual rooms by installing 

thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose 

a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly 

higher setting to make sure that even the coldest room is comfortable, then prevent any overheating 

in other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense the temperature, so they must not be covered by 

curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may prevent the 

thermostat from working properly.

Location

ST9420C

DT92E

(typically in living room or hallway)

CS92A

(typically next to hot water tank, in bedroom)

BDR91T

(If installed, typically next to boiler)

Summary of Contents for BDR91T

Page 1: ...he heating and hot water to run continuously run under the chosen On and Off heating periods or be permanently off The time on the programmer must be correct Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time You may be able to temporarily adjust the heating programme for example Override Advance or Boost These are explained in th...

Page 2: ...neywell Inc and its subsidiaries and existing under the laws of the UK and other countries These intellectual and property rights may include patent applications registered designs unregistered designs registered trade marks unregistered trade marks and copyrights Honeywell reserves the right to modify this document product and functionality without notice This document replaces any previously iss...

Page 3: ...r Hot Water Set Temperature 18 BOILER SERVICE REMINDER Countdown to Service When Service is Due 18 Shut down 19 OPERATING YOUR DT92E Inquiring about the Set Temperature Adjusting the Set Temperature 19 Switching Off Display Updates Heating Indicator Frost Protection 20 DT92E OPERATING INDICATORS Low Battery Indicator Battery Replacement RF Communications Indicator Lockout 21 DT92E ENERGY SAVING EC...

Page 4: ...omfort at the least cost The way to use a Programmer Think about the time periods when you are typically in the house and when you are not and also the times when you use a lot of hot water These are the times you should use as the basis for the programmes It will be necessary to allow some heat up time for the heating system after periods when it has been off this would typically be 1 1 hours dep...

Page 5: ...You won t have to adjust the thermostat further Any adjustment above this setting will waste energy and cost you more money DT92E has a green ECO button which enables you to set a period of time at a lower temperature This energy saving feature is most useful if you are out of the house for a few hours or if you want a reduced temperature for a while and don t want to have to remember to turn the ...

Page 6: ... followed by SET THE DAY and the day of the month will now be flashing to indicate it can be changed GETTING STARTED WITH YOUR ST9420C HOT WATER HEATING DAY TIME HOT WATER HEATING RUN using this to calculate the correct time to switch on to reach your comfort temperature when you want it So the times you set are when you want the heating to be at the correct temperature and the system adjusts the ...

Page 7: ...ve to the next step If the date you set was not valid for example 31 September the message INVALID will show and you will be returned to the start of the date setting operation e The time will now be flashing and the message SET THE TIME will be displayed To change the time press the or buttons until the correct time is shown Each press of the button will change the time by one minute Holding the ...

Page 8: ...in Programme Profile b ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3 Monday to Friday Heating 6 30am 9 30am 12 00pm 1 00pm 4 30pm 11 00pm Hot Water 6 30am 9 30am 12 00pm 1 00pm 4 30pm 11 00pm Saturday Sunday Heating 6 30am 9 30am 12 00pm 1 00pm 4 30pm 11 00pm Hot Water 6 30am 9 30am 12 00pm 1 00pm 4 30pm 11 00pm Built in Programme Profile C ON 1 OFF 1 ON 2 OFF 2 ON 3 OFF 3 Monday to Friday Heating 6 30am 7 30a...

Page 9: ...he next day to allow you to programme the hot water to stay on past midnight if required a Move the slider to the HOT WATER position SET HOT WATER will show briefly to verify this action b SET ON TIME 1 will then be displayed and the time setting for the first ON 1 time for MONDAY will now be flashing to indicate it can be changed If you do not wish to change the time press the green button and mo...

Page 10: ...ext ON OFF time without making any changes e After setting or reviewing the last off time OFF 3 the message COMPLETE will be displayed to indicate the times for Monday have been set You now have a choice of how to set the programme for the next day Copying One Day s Programme to Another Day example Monday to Tuesday f Whilst the day is showing Monday Press the COPY DAY button The message COPY MON ...

Page 11: ...NG will show briefly to verify this action b Now follow the same procedure to set the times as described in Modifying the Hot Water Programme page 9 steps b to i Exiting HEATING Programming Mode To exit HEATING programming mode move the slider to the RUN position This can be done at any time during the programming process and any changes made and confirmed with the button will have been saved Note...

Page 12: ... AUTO Automatic mode The heating will be switched ON and OFF according to the heating programme ONCE mode The heating will come ON at the first programmed ON time and go OFF at the last programmed OFF time CONT Continuous mode The heating will remain ON continuously The hot water MODE button operates in the same way as described above for the heating MODE button Overriding the Operation Without Ch...

Page 13: ... but resumes normal operation on the day of your return During this period heating will operate at the OFF frost protection set temperature and the hot water will remain off To set the Holiday function a Ensure the slider is in the RUN position then press the HOLIDAY button once The message SET HOLIDAY will appear briefly followed by SET DAYS AWAY b Use the or buttons to set the number of days you...

Page 14: ...ormation is being viewed and the main display will show the value If the information is not available the display will show dashes instead of a temperature value The table below shows the type and sequence of information available in Enquiry Mode To exit Enquiry Mode If the button is not pressed for 30 seconds your ST9420C will return to RUN mode Information LoT Message Other display symbols Room ...

Page 15: ...s that are possible Your installer should set this up for you to suit your application see CONFIGURATION SERVICE DATA section However you may wish to alter some of the settings yourself and this section shows you how to do this Note some parameters indicated by may only be viewed if the previous parameter is set to a particular value INSTALLER PARAMETER Parameter Number Default Value Options Descr...

Page 16: ...by pressing the or buttons At this point the description in the LoT Display will change and the parameter value will flash If you press the value will stop flashing and be saved for use INSTALLER PARAMETER Parameter Number Default Value Options Description Optimum start 9 0 0 1 2 0 no optimum start 1 delayed start 2 optimum start on Optimum start limit 10 1 1 2 3 1 1 hour 2 2 hours 3 3 hours Optim...

Page 17: ...misation The Optimisation features are explained on page 5 Parameters 9 10 and 11 are used to enable or disable and set these features to suit your requirements You can set Optimum Start Delayed Start or Optimum Stop and you can also set a limit to the Optimum Start time of 1 2 or 3 hours Note the radiator symbol will flash to indicate Optimisation is taking place The diagrams below illustrate how...

Page 18: ...r may also have been programmed into the ST9420C If so a message will appear on the LoT Display indicating the number you should call Countdown to Service Your ST9420C can indicate a countdown for the number of days until your service is due This message will appear on the screen every few seconds to give you an opportunity to schedule a service visit When Service is Due When your boiler service i...

Page 19: ...own However you should still arrange an immediate service visit as this will allow you to comply with the law and ensure your gas boiler is operating safely BOILER SERVICE REMINDER OPERATING YOUR DT92E Inquiring about the Set Temperature DT92E normally displays the measured room temperature To inquire about the set temperature simply press one of the or buttons The set temperature will be shown on...

Page 20: ...can be up to a few minutes delay between an action initiated on ST9420C and the DT92E display being updated If you press a button on DT92E it may take a few seconds for ST9420C to respond DT92E will indicate it is waiting for information by displaying the hourglass symbol and dashes as shown Heating Indicator The flame symbol indicates that the boiler is on for heating The flame will disappear whe...

Page 21: ... power up DT92E will try to communicate and synchronise with ST9420C This process may take up to 4 minutes and will be indicated by the word Sync on the DT92E display RF Communications Indicator A brief flash of the RF symbol indicates the DT92E has been communicating with the other system controls Lockout Your DT92E works in conjunction with the ST9420C time control If the timer is set to OFF or ...

Page 22: ...CO button to enter ECO mode The word ECO will appear on the display and the thermostat will allow you to set the number of hours you want to be at the new set temperature Use the and buttons to set the hours up to a maximum of 24 hours Please note ECO mode is not accessible in Holiday mode or if Service shutdown has occurred What Happens in ECO Mode In ECO mode the display will show a countdown of...

Page 23: ...s you how to do this INSTALLER PARAMETER Parameter Default Value Options Description Temperature measurement offset t0 0 3 to 3 K Offset to measured temperature Upper setpoint limit uL 35 21 to 35 C Upper set temperature limit in C Lower setpoint limit LL 5 5 to 21 C Lower set temperature limit in C Energy saving ECO setpoint ES 18 5 to 35 C Energy saving ECO set temperature in C Reset parameters ...

Page 24: ... one parameter to the next Stop at the Parameter you wish to change To Change a Parameter Use the standby button to select the parameter value then the and buttons to change the value Confirm the change by pressing the button again to take you back to the parameter To Exit Installer Mode Hold the button for 3 seconds to exit Installer Mode Note The Installer Mode will exit automatically after 10 m...

Page 25: ...pping the front cover at the bottom Note battery polarity Reverse process to refit front cover Use 2xLR6 AA alkaline batteries only Error Indications To save battery power CS92A will indicate error conditions on the LoT Display of ST9420C It is possible to view the CS92A sta tus by pressing the button on the transceiver box The lights underneath this button will provide feedback as shown in the ta...

Page 26: ...ble to press the button and temporarily override the current relay position This will be cancelled as soon as the Relay Box receives another signal from the ST9420C because automatic operation has a higher priority than manual operation Loss of Wireless Communications If the RF communication is lost for a period of 1 hour the red light will illuminate The Relay Box will then enter the failsafe mod...

Page 27: ...r Installer has configured your product What should I do if I get lost while programming the ST9420C The LoT Display on ST9420C will provide you with help and tips to work through the programming Should you ever get lost the simplest thing to do is to move the slider to the RUN position and then move it back to the appropriate programming position where you got lost At this point just follow the i...

Page 28: ...E is blocked by a metal object Check the direct path between the two devices and reposition any object that may be blocking the signal or move the thermostat How do I know when to change the batteries in the CS92A cylinder sensor If the CS92A batteries need changing the ST9420C will show the message SENSOR LOW BATT and the tap symbol will flash You can confirm this by pressing the CS92A button whe...

Page 29: ...the counter reaches zero After servicing your boiler the Service Engineer Installer will reset the ST9420C to remind you when the next boiler service is due Each service is normally a maximum of 1 year apart Although the heating is still operating the ST9420C screen keeps flashing the message Your boiler service is overdue Arrange an immediate boiler service After servicing your boiler the Service...

Page 30: ...ce is due Each service is normally a maximum of 1 year apart ST9420C shows the message SENSOR LOW BATT and a flashing radiator symbol Your DT92E batteries are running low on power Change the DT92E batteries see page 21 for how to do this DT92E shows a flashing battery symbol DT92E display is blank ST9420C shows the message SENSOR LOW BATT and a flashing tap symbol Your CS92A batteries are running ...

Page 31: ...tery power Your CS92A batteries are running low on power Change the CS92A batteries This is located next to your hot water storage tank see page 25 for description of how to change the batteries RF communication path between ST9420C and CS92A is blocked possibly by a metal object Check direct path between both products and re position any objects that may be blocking the signal ST9420C shows the m...

Page 32: ...p symbol CS92A sensor error indication Press CS92A button and red light blinks 0 5s on 0 5s off Note light will switch off after approx 1 minute to save battery power CS92A sensor cable may be disconnected from the wiring terminals Re connect the sensor wired to the CS92A terminals Fault with CS92A Call Installer ...

Page 33: ...33 ...

Page 34: ... button pressed on continuously Automatic time change disabled enabled 1 day or 5 2 day or 7 day operation 1 day operation 5 2 day operation 7 day operation Number of ON OFFs per day 2 on offs per day 3 on offs per day Default time programme A standard b at home C economy Hot water set temperature From 40 to 85 C 60 C Optimum start no optimum start delayed start optimum start on Optimum start limi...

Reviews: