Honeywell ADEMCO VA8201 Installation And Setup Manual Download Page 1

K5443V1 10/04  Rev. A 

 

 

ADEMCO VA8201 

Alpha Pager Module 

INSTALLATION AND SETUP GUIDE 

GENERAL INFORMATION 

The ADEMCO VA8201 Alpha Pager Module (APM) 
provides: 

• 

Communication between the control panel and an alpha 
paging service center.   

• 

Data transfer to a parallel printer via the APM’s 
parallel output.   

• 

Data transfer to PCs with IBM Home Automation 
Protocol or a serial printer via the APM’s serial output.   

NOTE:  

The paging feature of the VA8201 may not work 

with all alpha paging service centers.  Data transfer 
features between the control and printers will still function 
even if the paging feature does not.     

The APM transmits alphanumeric messages to the paging 
service using Telocator Alphanumeric Protocol (TAP).  The 
installer should check with the paging service to ensure 
they are using TAP protocol Rev. 1.8.   

The types of messages that can be transmitted are security 
control panel dependent.  The APM sends alphanumeric 
messages to the paging service when a programmed security 
control panel initiates an event report.   

Refer to the Ademco Security Control Panel Installation and 
Setup Guide for the types of messages available and for 
event report programming.   

INSTALLING THE VA8201 APM 

The VA8201 APM is installed sharing the same telephone 
line as the security system control panel.  In this 
configuration, conditions that are programmed to report to 
both the central station and the alpha pager will report to 
the central station first.  When a parallel printer is 
connected to the parallel printer output of the APM, the 
security system control sends its event data to the printer 

before it sends the APM messages to the pager service or 
the Home Automation Computer.   

MOUNTING AND WIRING THE VA8201 APM   

Mount the VA8201 APM next to the security system control 
panel using bracket interface Ademco Part Number K5350.  
Wire the VA8201 APM’s four flying leads (DATA/POWER) 
and TELCO connections (TO LINE and TO PHONE) to 
security system control and premises handsets.  Wire the 
VA8201 APM in accordance with Figure 1.  Use appropriate 
ADEMCO accessories (or equivalent) to make system 
connections.   

NOTE:  

To comply with FCC Class B (Residential) 

requirements, the VA8201 APM must be mounted in a 
grounded metal enclosure.   

PROGRAMMING 

Refer to the Programming section of the Installation and 
Setup Guide for your control on how to program phone 
numbers, Alarms, and Trouble Reports when using the 
Alpha Pager Module.   

NOTE:  

Prior to programming the VISTA control for use 

with the APM and paging device(s), verify the correct access 
and PIN number to be used with each receiving device.  
Entering an incorrect access or PIN number will render the 
pager inoperable for alarm panel reporting.   

SPECIFICATIONS 

Dimensions: 

6-1/4” L x 6-1/8” W x 1-13/16” H.   

Voltage: 

12 Volts DC 

Current: 

63mA (standby mode), 165mA (active 
mode) 

VA8201 ALPHA PAGER MODULE

AUX

PWR.

PARALLEL
PRINTER

PARALLEL
OUTPUT

SERIAL

OUTPUT

DATA/

POWER

TO PHONE

RJ11

EARTH 

GROUND

HOME AUTOMATION COMPUTER

RED

BROWN

GRAY

GREEN

RED

BLACK

GREEN

RED

BLACK

GREEN

AUX
GND.

6

26

27

28

29

30

23

7

TIP RING

HANDSET

TIP RING
INCOMING

620

PHONE

CORD

(ZONE 9)

BROWN WIRE

FROM 4142 TR

TRIGGER CABLE

SPLICE

V

A

8201-SOC-V1

1  2  3  4  5  6  7  8  9

J8

BR

O

W

N

ORANGE

CONTROL PANEL

NOTE

WHEN USING THE VA8201, ZONE 9 CAN NO
LONGER BE USED AS A PROTECTION ZONE.

RJ31X

1

2

3

4

5

6

7

8

RING

TIP

INCOMING

PHONE LINE

TO

PREMISES

PHONES

GREEN

RED

GREY

BR

O

W

N

RING

TIP

TO LINE

RJ11

 

Figure 1.  VA8201 Alpha Pager Module Summary of Connections 