background image

 

 

 

K0315  12/02  Rev. D

ADEMCO 269R/270R 

Holdup Switch

INSTALLATION AND SETUP GUIDE 

GENERAL INFORMATION 

The ADEMCO 269R/270R Holdup Switch (Figure 1) is a finger-
operated switch for activating the holdup signal at the control 
and/or any other security application.  The 269R adds a protective 
steel cover.  The Holdup Switch is typically mounted under a 
counter for inconspicuous operation.  The device comes standard as 
a latching type switch that is easily converted to a non-latching 
type.   

If the switch is used as a latching type switch, the supplied reset 
key is used to reset the device.  Additional reset keys may be 
obtained separately by ordering ADEMCO part number K4563.   

PROGRAMMING  

For Honeywell controls, program the unit like any other zone, 
according to the control’s installation and setup guide.  Enter the 
following information when prompted for in zone programming: 

“ZONE TYPE” = “06”  

“INPUT TYPE” = “01”   

For other manufacture controls, refer to the controls instructions 
for specific programming instructions.   

MOUNTING 

Refer to the steps and figures that follow for typical mounting 
installation.  If required, convert the latching device to a non-
latching device as shown in figure 2.   

1.

 

Run the wiring from the control panel to the device, through 
the opening in the case back as shown in Figure 3.   

2.

 

Wire the device for a normally closed or a normally open loop 
with no EOL resistor or for a normally-closed or a normally 
open loop with an EOL resistor as shown in figure 3, detail A 
and B, respectively.  Where Form C wiring is required, 
providing full supervision of the loop refer to figure 3, detail C.     

3.

 

Secure the cover to the case with two screws (No. 6 x 7/8) as 
shown in figure 1.  Note the cover screws are noticeably 
shorter than the mounting screws. Be sure to use the correct 
holes.  The holes opposite these are used to secure the device to 
the counter.

  

 

IMPORTANT: To prevent damage to the case do not 
over tighten the cover screws.   

4.

 

Peel the backing from the double stick tape strips on the back 
of the device and position the device in its mounting location.  

IMPORTANT:

   

The double stick tape is provided to 

temporarily hold the assembly in place while drilling 
the pilot holes.  The device must be permanently 
mounted with the screws supplied.

   

5.

 

Using the case as a drill template, drill a 1/16” diameter pilot 
hole at the two case mounting holes (Figure 1). 

6.

 

Secure the assembled case with the protective cover (if 
required) to the counter with two screws (No. 6 x 1-3/4) 
supplied. (Figure 4).   

 

+

+

MOUNTING

HOLE

TRIGGER

RESET KEY

(K4563 SUPPLIED)

MOUNTING

HOLE

COVER

SCREW (2)

No. 6x7/8

PROTECTIVE

STEEL

COVER

(269R ONLY)

CIRCUIT

BOARD

COVER 

ATTACH HOLE

COVER

ATTACH 

HOLE

MOUNTING

SCREW (2)
No. 6X1 3/4

COVER

SCREW

COVER

269R-001-V1

 

Figure 1 

TRIGGER

ASSEMBLY

TO CONVERT TO MOMENTARY (NO LATCHING) SWITCH
OPERATION, REMOVE THE TRIGGER ASSEMBLY FROM THE
CASE. USING A PAIR OF CUTTERS, CUT THE TRIGGER LATCH
AT THE POINT THE "ARROW" IS  STAMPED ON THE CASE. 

TRIGGER

LATCH

ARROW

(CUT POINT)

269R-004-V0

 

Figure 2

 

NO

EOL

NC

C

NO

EOL

NC

C

269R-007-V1

WIRE AS SHOWN FOR
A NORMALLY-CLOSED

LOOP WITH NO EOL

RESISTOR.

WIRE AS SHOWN FOR

A NORMALLY-OPEN

LOOP WITH NO EOL

RESISTOR.

DETAIL A

 

 

NO

EOL

NC

C

NO

EOL

NC

C

269R-008-V1

WIRE AS SHOWN FOR
A NORMALLY-CLOSED

LOOP WITH AN EOL

RESISTOR.

WIRE AS SHOWN FOR

A NORMALLY-OPEN

LOOP WITH AN EOL RESISTOR.

NOTE THAT THE EOL

TERMINAL IS NOT USED

IN A NORMALLY OPEN LOOP.

DETAIL B

 

Figure 3 

NO

EOL

NC

C

NO

EOL

NC

C

269R-012-V1

CONTROL PANEL

ZONE TERMINALS

FORM "C"

WIRING  PROVIDES
FULL SUPERVISION

OF THE LOOP

DETAIL C

 

 

Reviews: