72
System Administration and Settings
Restoring Factory Defaults
There are two types of factory defaults that can be restored either directly on the dome
using a DIP switch or via the OSD Diagnostic Options menu. There is an important
distinction between the two.
•
Using the OSD menu restores all of the camera and dome configuration settings to
the factory defaults, but DOES NOT delete user programmed configurations (presets,
preset tours, mimic tours, sectors and privacy zones).
•
Using DIP switch SW3-7 restores all the settings to defaults and DOES delete any
user programmed configurations (presets, preset tours, mimic tours, sectors and
privacy zones).
Restoring Defaults Using the OSD
•
Select
4 Diagnostic Options
>
6 Restore Default Settings
>
Y
or
N
to cancel.
The message
This will restore all user default settings to their
default values
displays.
All of the default configuration settings are restored to the factory defaults, without
deleting user programmed configurations (presets, preset tours, mimic tours, sectors
and privacy zones).
Restoring to Factory Defaults Using Switch SW3-7
Note
The switch is read only at power up. See
DIP Switch Default Settings and
for more information.
1.
Locate switch SW3-7.
2.
Carefully place the switch in the required position.
•
(Default)
Normal operation: Select
OFF
.
•
To restore factory default settings and delete any user programmed
configurations (presets, preset tours, mimic tours, sectors and privacy zones):
Select
ON
.
3.
After the factory default is restored, set switch back to
OFF
position to prevent
unwanted deletion of user programmed configurations.
Resetting the Camera Lens
•
Press
98
>
Preset
.