Configuring the Pan, Tilt and Zoom (PTZ) and Dome Control Settings
Task/Action with Default
Notes
Turning the Pan and Tilt Speed Range (PASS) ON and OFF
•
Select
3 Control Options
>
1 PASS
>
ON
(default) or
OFF
.
PASS is a function of the lens zoom angle. The
maximum pan and tilt speeds are reduced when the
lens zooms in. For example, the pan and tilt functions
are slow when the dome is set at 12X zoom. The higher
the zoom magnification, the slower the speed.
Turning the Auto Pivot ON or OFF
1. Select
3 Control Options
>
2 Auto Pivot
>
ON
(default) or
OFF
.
Track people passing directly underneath the dome.
The dome automatically turns 180
°
when it reaches its
lower limit. It continues to tilt up as long as the controller
tilt function remains in the down position. When the
dome reaches its tilt up limit, it returns to normal
operation.
Changing the Degree of the Manual Pan and Tilt Speed
•
Select
3 Control Options
>
4 Set Pan and Tilt
Options
>
1 Manual Speed deg/s
>
90
°
/sec
or
180
°
/sec
or
360
°
/sec
(default).
The maximum tilt speed is half of the maximum pan
speed.
Turning the -2
°
Tilt Limit ON or OFF
•
Select
3 Control Options
>
4 Set Pan and Tilt
Options
>
4
–2
°
Tilt Limit
>
ON
or
OFF
(default).
ON positions the dome tilt to 2
°
above horizontal.
Finding the Mechanical Home on Startup
1.
Select
3 Control Options
>
4 Set Pan and Tilt
Options
>
5 Find Home on Startup
>
2.
Select
ON
or
OFF
(default).
If you select ON, the message
Extreme
Caution: This will cause the scan to
move immediately on startup...
displays.
•
Select
Y
(yes) to continue or
N
(no) to cancel.
•
ON sets the dome to find the mechanical home (or
index) position after an initial startup delay of 15
seconds.
•
OFF sets the unit to find home when powered up
and the dome performs a control command.
•
When a privacy zone is enabled, no video is
shown during the finding home process and
privacy zones are not recognized until the dome
reaches home. Once the dome finds home, a
picture can be viewed on the monitor unless a
privacy zone overlaps with this home setting. See
Turning the Pan Offset ON or OFF
•
Select
3 Control Options
>
4 Set Pan and Tilt
Options
>
6 Pan Offset
>
1 Pan Offset
>
ON
or
OFF
(default).
Pelco P and D protocols only: The pan offset feature is
not available due to the preset index starting at 1
(instead of 0).