PRODUCT DESCRIPTION
Activ8 DT
Activ8 DT
Activ8 DT
Activ8 DT
PASSIVE INFRARED &
MICROWAVE
MOTION DETECTOR
With PET IMMUNITY
INSTALLATION INSTRUCTIONS
P/N 7101491 REV. A A.Y.
A new generation of professional
movement spread spectrum analyzing PIR
& MW detectors.
The Activ8 DT is a combination of PIR & MW
detectors, providing protection from intruders by
PYRO sensor element and MW (based on Doppler
concept).
Using micro controller for PIR & MW signal
analyzing, with special ASIC technology for PIR
pulse processing, assures “false alarm free”
operation.
Activ8 DT FEATURES
DETECTION PATTERN
TYPICAL INSTALLATION
FEATURES
•
Quad (Four element) PYRO sensor and
hard lens for outstanding detection
performance and elimination of false
alarms.
•
Microwave detection based on Doppler
concept.
•
Unique Microwave Motion Sensor Module
with microstrip patch antenna.
•
VLSI based electronics with movement
speed spectrum analysis.
•
Height installation calibrations free.
•
User-friendly installation with or w/o swivel
bracket.
•
2-way Microwave sensitivity adjustment.
•
2-way PIR sensitivity adjustment.
•
BI directional temperature compensation.
•
Environmental
immunity.
•
The Activ8 DT provides
pet immunity
up to
25Kg. Pet active bellow 1m.
SELECT MOUNTING LOCATION
Choose a location most likely to intercept an
intruder. (Our recommendation is a corner
installation). See detection pattern. The quad-
element high quality sensor detects motion
crossing the beam; it is slightly less sensitive
detecting motion toward the detector.
The Activ8 DT performs best when provided with
a constant and stable environment.
AVOID THE FOLLOWING LOCATIONs
•
Facing direct sunlight.
•
Facing areas that may change temperature
rapidly.
•
Areas where there are air ducts or
substantial airflows.
The Activ8 DT performs better when provided
with a constant and stable environment.
REMOVAL OF FRONT COVER
MOUNTING DETECTOR BASE
1. To remove the front cover, unscrew the holding
screw and gently raise the front cover.
2. To remove the PC board, carefully unscrew the
holding screw located on the PC board.
3. Break out the desired holes for proper installing.
4. The circular and rectangular indentations at the
bottom base are the knockout holes for wire
entry. You may also use mounting holes that are
not in use for running the wiring into the
detector.(For option with bracket - lead wire
through the bracket)
5. Mount the detector base to the wall, corner or
ceiling. (For option with bracket install bracket).
6. Reinstall the PC board by fully tightening the
holding screw. Connect wire to terminal block.
7. Replace the cover by inserting it back in the
appropriate closing pins and screw in the holding
screw.
KNOCKOUT HOLES
DETECTOR INSTALLATION
CIRCUIT LAYOUT
TERMINAL BLOCK CONNECTIONS
Terminals 1 & 4 - Marked “ EOL ” –
End of line
option.
Terminals 2 & 3 - Marked “ TAMPER ”
If a Tamper function is required connect these
terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the
detector is opened, an immediate alarm signal will
be sent to the control unit.
Terminals 5 & 6 - Marked
“
RELAY
”
These are the output relay contacts of the
detector. Connect to a normally closed zone in the
control panel.
Terminal 7 - Marked “ + ” (+12V)
Connect to a positive Voltage output of 8.2 -16Vdc
source (usually from the alarm control unit)
Terminal 8 - Marked “ - ” (gnd)
Connect to the negative Voltage output or ground
of the control panel.
A. Wire
access
holes
B. Use for flat wall
mounting
C. Corner mounting -
use all 4 holes.
Sharp left or right
angle mounting -
use 2 holes (top
and bottom)
D. For
bracket
mounting
D
B
B
B
B
C
C
C
C
Unscrew the holding
screw and open base
A
A
A
15m
The Activ8 DT provides immunity up to
25Kg. For better immunity avoid
installation in areas where pets can reach
upwards.