69-2718EF—03
50
System setup
(See page 48 for instructions.)
Function
Settings & Options
1
Select System
Type
If you are not sure
of your heating/
cooling system
type or have other
questions, go to
wifithermostat.com
0
Heat/cool: Gas, oil or electric heating with central air conditioning.
1
Heat pump: Heat pump without backup or auxiliary heat.
2
Heat only: Gas, oil or hot water heat without central air conditioning.
3
Heat only with fan: Gas, oil or electric heat without central air
conditioning.
4
Cool only: Central air conditioning only.
5
Heat pump: Heat pump with backup or auxiliary heating.
6
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2
cooling stages (wires on
Y and Y2).
7
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1
cooling stage (wire on
Y).
8
Heat/Cool Multiple stages: 1 heat stage (wires on W), 2 cooling stages
(wire on
Y and Y2).
2
Heat Pump
Changeover Valve
(for heat pumps
only)
0
Cooling changeover valve: Use this setting if you connected a wire
labeled “O” to the O/B terminal.
1
Heating changeover valve: Use this setting if you connected a wire
labeled “B” to the O/B terminal.