background image

Page 1

 

 

K5942V2   7/04 

5894PI 

PASSIVE INFRARED MOTION DETECTOR/TRANSMITTER 

 

INSTALLATION INSTRUCTIONS 

 

GENERAL INFORMATION 

The 5894PI Passive Infrared Motion 
Detector/Transmitter is a 10-year battery-
operated wireless device intended for use as 
part of a 5800 series wireless alarm system.  

Designed for use in commercial and residential 
installations, the 5894PI is a wall-mounted unit 
with a standard lens that provides wide-angle 
protection up to a range of 35 ft (10.6m). For 
best coverage, mount the detector so that the 
likely direction of intruder motion is 

across 

the 

pattern.  

When installed per the guidelines, the Tier-
Balanced Optics technology in the 5894PI 
provides false alarm protection against pets 
and other animals up to 80 lbs. 

This document provides installation instructions 
for the 5894PI, but the installer must be familiar 
with the installation instructions for the 5800 
Wireless Alarm System with which the 5894PI 
is intended to be used. 

 

FEATURES 

•  Tier-Balanced Optics provides pet immunity 

against animals up to 80 lbs. 

•  Wireless operation for fast installation. 

• Dual-element pyroelectric sensor provides 

positive protection while minimizing false 
alarms. 

•  Selectable PIR sensitivity. 

•  Provision to turn LED on while Walk Testing 

(LED is turned off after testing). 

•  Tamper-protected cover and wall; detector 

transmits message if cover or detector is 
removed. 

•  Wall or corner mounting options. 

•  Patented Black Bug Guard. 

• Temperature 

compensation. 

 

SYSTEM DESCRIPTION 

Optical System 

The 5894PI uses efficiently designed Fresnel 
lenses with Tier-Balanced Optics. 

Radio Transmitter 

The built-in transmitter serves only as the 
communication link to the alarm system's 
Receiver/Control, and can send alarm, tamper, 
supervisory, and battery status messages to 
the system's receiver/control. The transmitter is 
not used for detection purposes. Each detector 
has a unique ID code permanently assigned at 
the factory. You must enroll this ID into the 
control system at the time of installation. This 
allows each detector used in the system to be 
uniquely identified. You must program the 
control to enroll the 5894PI as an "RF" type unit 
(i.e., supervised RF).  

To conserve battery life during normal 
operation, no more than one transmission 
sequence will occur within a 3-minute period. 
There is no such time restriction in Test mode 
(refer to the Walk Test section). 

 

 

 

SPECIFICATIONS 

Pet Immune Lens

:  

35 ft x 45 ft (10.6m x 13.7m). 
28 zones (8 over, 8 long range, 8 intermediate, 
4 short-range). 

Pulse Processing:   

Intermediate, Standard, or Harsh, Installer-
selectable.  

Note: For pet immune applica-

tions, see Special Instructions for 
Installations with Pets on page 3. 

Detectable Walk Rate:   

0.5–10 ft/Sec (0.15–3m/Sec). 

Mounting Height:   

7.0 ft (2.1m) 

Walk Test Indicator: 

Red LED with enable/disable link. 

Batteries:

  

Three

 

3-volt Lithium batteries. Use only 

ADEMCO No. 466, Duracell DL123A, 
Panasonic CR123A, Sanyo CR123A, or Varta 
CR123A. 

0perating Temperature:   

32°F – 122°F (0°C - 50°C). 

Operating Humidity:

   

Up to 95% RH (max.), non-condensing. 

Dimensions:  

3.0"W 5.0"H x 1.7"D 
(76.3mm x 127.0mm x 42.6mm). 

Approvals/Listings:

  

FCC, IC, cULus, C-Tick 

0

22.5'

22.5'

10'

20'

30'

35'

0

7'

0

10'

20'

30'

35'

SIDE VIEW

TOP VIEW

ALTERNATE 

COUNT POLARITY

EACH ZONE CONSISTS 

OF 2 FIELDS

 

Figure 1. Protection Pattern 

BATTERY ACTIVATION/INSTALLATION 

1.  Remove front cover by pressing the front 

cover latch and lifting the cover off.  See 
Figure 2. 

 

 

Figure 2. Remove the Front Cover 

2. To 

activate the installed batteries, remove 

the battery pull-tab. (See Figure 3.)  Make 
sure the batteries remain firmly seated in 
the battery holders. 

 

Figure 3. Remove Pull Tab to  

activate batteries 

3. To 

replace the batteries, remove the old 

batteries from the holder.  Then, 

observing 

correct polarity, 

install three new Lithium 

batteries into the battery holders,

 

as shown 

in Figure 4. Make sure the batteries are 
firmly seated. 

4.  Replace the cover (snap fit). 

 

Battery Caution 

Risk of fire, explosion, and burns. Do not 
recharge, disassemble, heat above 100°C, or 
incinerate. Dispose of used batteries promptly. 
Keep away from children. 

 

Summary of Contents for 5894PI - Ademco Wireless PIR Motion Sensor

Page 1: ...actory You must enroll this ID into the control system at the time of installation This allows each detector used in the system to be uniquely identified You must program the control to enroll the 5894PI as an RF type unit i e supervised RF To conserve battery life during normal operation no more than one transmission sequence will occur within a 3 minute period There is no such time restriction i...

Page 2: ...g transmission path between the 5894PI and the system s Receiver Control exists before permanently mounting the detector Do this by performing the Walk Test described later with the detector temporarily mounted in its proposed location The 5894PI will transmit when sensing motion such as a person waving an arm or walking into an area Sometimes moving the detector only a few centimeters means the d...

Page 3: ...hould be followed Mount the center of the detector 7 0 feet high Set the Pulse Count to Standard or Harsh Mount where animals rodents cannot come within six feet of the detector by climbing on furniture boxes or other objects Do not aim the detector at stairways or furniture objects that can be climbed by an animal Note This unit will provide immunity to false alarms for an individual animal or a ...

Page 4: ... or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio television technician for help Changes or modifications to this equipment not expressly approved by Honeywell may void the user s authority to operate t...

Reviews: