Step-by-Step 

Tech Support 

 Updated 7/27/10 

4286/4500 Voice Module Set up and Troubleshooting 

 

In this document we will discuss the following: 

1.

 

Pre-Installation Notes

 

2.

 

The Wiring

 

3.

 

System Programming

 

4.

 

4286 1

st

 Time Accessing and Programming

 

5.

 

4500 Integration

 

6.

 

4500 Troubleshooting

 

7.

 

4286 Troubleshooting

 

8.

 

Voice Descriptor Word List

 

 

Pre-Installation Notes: 

1.

 

VOIP phone service is not supported. 

2.

 

DSL requires an RJ31X DSL filter. 

 

Wiring Notes: 

1.

 

When using a power supply you MUST share a common ground with the control panel.

 

2.

 

The 4286 wires up directly to the keypad Terminals on your Control panel.

 

3.

 

Observe the panels ECP (keypad data) wire runs and do not exceed the 2000’ max distance the panel offers 
(1500’ on vista20 and lower control panels).

 

4.

 

Existing wires connected to the “Handset” terminals on control must be moved from there to terminals 3 
and 4 on the 4286.

 

5.

 

Place a 2 conductor wire between terminals 21 and 22 to terminals 1 and 2 on the 4286.

 

 

 

Figure 1: Vista-10/15/20p Wiring

 

Summary of Contents for 4286

Page 1: ...supported 2 DSL requires an RJ31X DSL filter Wiring Notes 1 When using a power supply you MUST share a common ground with the control panel 2 The 4286 wires up directly to the keypad Terminals on your Control panel 3 Observe the panels ECP keypad data wire runs and do not exceed the 2000 max distance the panel offers 1500 on vista20 and lower control panels 4 Existing wires connected to the Handse...

Page 2: ...Support Updated 7 27 10 Figure 2 Vista 40 50 128b bp 250bp Figure 3 Vista 32fb 128fb fbp 250fbp System Programming Notes 1 The 4286 has a Non Changeable address of 04 and can not be changed See below for programming on various panels ...

Page 3: ... 2 digit access code Enter 1 9 for Customers with out an answering machine or a dedicated line to the panel If they have an answering machine you can use the Answering Machine Defeat option by Entering 15 here This requires the customer to call let ring once hang up and call back 4 10 15 20p Notes 4286 Phone Modules must have software version WA4286 15 1 V101 or higher refer to the label on the sq...

Page 4: ...the telephone keypad Upon Doing so the panel will start speaking the 1st programming location and it value It will say Field 00 is 00 Programming can only be accessed within 3 hours of power up After programming the 98 mode you only have 15 minutes to re access it If it has been longer than that you can simply power the 4286 down for 5 seconds then back up and you have your 3 hour time window agai...

Page 5: ... 0 50 0 30 3 0 75 0 40 3 0 75 0 40 4 1 00 0 60 4 1 00 0 60 5 1 50 0 80 5 1 50 0 80 6 2 00 1 10 6 2 00 1 10 7 2 50 1 40 7 2 50 1 40 Figure 5 Swing Points Do Not Select a 1 1 This field defines how many degrees below the set point the heat will turn on and how many degrees above the set point the heat will turn off These values also define the swing of the air conditioner operation 06 Announce the T...

Page 6: ...IGHT 139 GLASS 063 POWER 069 0 125 BUILDING 166 PUMP 070 1 039 BURGLARY 050 HALL 136 1ST 010 HEAT 088 REAR 071 2 003 CALL 028 RIGHT 056 2ND 089 CENTRAL 209 INSIDE 018 ROOM 072 3 054 CHIME 159 3RD 126 CLOSED 022 KITCHEN 007 S 073 4 127 COMPUTER 150 SERVICE 217 4TH 140 LAUNDRY 151 SHED 218 5 208 DAUGHTER S 027 LEFT 152 SHOP 075 5TH 052 DEN 141 LIBRARY 153 SIDE 219 6 128 DETECTOR 019 LIGHT 024 SMOKE ...

Page 7: ...onnecting power to the thermostat 4 While installation of the 4500 is possible without the services of a HVAC contractor some installers will prefer to have an HVAC contractor connect the 4500 to the HVAC system and test its operation This is recommended if you do not have HVAC experience In cases where you prefer to do the entire installation it is suggested that the HVAC contractor be contacted ...

Page 8: ... adjust the temperature It has a Thermistor built on it that detects the temperature of the room When it determines that the temperature is above or below the set back it opens up the relay to prevent voltage feed to HVAC system preventing it from coming on at existing thermostat setting it then uses 4500 settings When temperature reaches Set back setting Relay will close to allow the on premise t...

Page 9: ...ting for thermostat 1 will follow You can change its set point using menu selection 1 below If thermostat 1 is in BYPASS or CHECK that status will be announced instead of the set point The 4286 will also announce whether set back has been turned off by the user Menu Selections To change temperature enter 1 This selection is used to set the armed away set back temperature for thermostats 1 or 2 Thi...

Page 10: ...on where the 4500 is mounted is free of drafts Temperature in the room swings too widely when the 4500 is set to ACTIVE mode 1 Decrease the amount of span as described in the section Programming the 4286 to add 4500 thermostats in Section 4 of the manual Also see figure 7 above for programming locations Troubleshooting the 4286 Problem When I enter the phone code on premise the operator comes on o...

Page 11: ...plug on the 4286 and not the plug intended for the 4500 make sure it is plugged in with yellow towards the center of the board Meter for voltage or data at the harness and on the pins when pulled back a little Take everything else off the ECP buss and test again to confirm there is not a current overload or address conflict 4 Tones generated by phone are not long enough or not correct Hold the key...

Reviews: