USER MENU STRUCTURE
Press the Menu button on the keypad to display the User Menu. Fig. 3 illustrates all possible User Menu selections.
Fig. 3. User Menu Structure.
AQUATROL® is a registered trademark of Resideo.
M27700
BOILER UNITS: °F
ZONE UNITS: °F
TIME DISP: 12H
D.S.T.: ENABLE
YEAR: 2008
MONTH: JAN
DATE: 1
DAY: MONDAY
TIME: 12:00A
HOMEPAGE: DETAIL
BACKLIGHT: AUTO
POWER FAILURE
NOTICE: BACKLIGHT
PREFERENCES / TIME
SYSTEM STATUS
PREFERENCES/TIME
ZONE SETTINGS
PROGRAM SETTINGS
STATISTICS
USER MENU
A/C MIN OFF TIME
A/C MIN ON TIME
AUX IN EM.SHUT
BOILER: IDLE
CALL FOR COOL
CALL FOR DHW
CALL FOR HEAT
CWSD ACTIVE
DHW DISABLE
INJECTION%: 0%
LOST ZONE A-1
...
LOST ZONE D-16
MIN RETURN PROT
NO DHW PROBE
NO LINE VOLTAGE
NO OUTDOOR PROBE
NO RETURN PROBE
NO SECOND. PROBE
NO SUPPLY PROBE
SHORT CYCLE PROT
VALVE INIT
WATER READY
WWSD ACTIVE
SYSTEM STATUS
1
ZONE A-1
ROOM TEMP
FLOOR TEMP
SETPOINT: 70
FLOOR SETPT: 70
HEAT/COOL STATUS
SETBACK: 7
SETPOINT MAX: 100
SETPOINT MIN: 41
FLOOR LIM HI: 100
FLOOR LIM LO: 41
SETPOINT VACANCY
HEAT: 41
SETPOINT VACANCY
COOL: 100
CHANGEOVER: 2
KEYBOARD: UNLOCK
ZONE SETTINGS (All or Single)
2
ARE YOU SURE?
NO YES
MON WAKE 6:00A
MON LEAVE 8:00A
MON RETRN 4:30P
MON SLEEP 10:00P
...
SUN WAKE 6:00A
SUN LEAVE --:--
SUN RETRN --:--
SUN SLEEP 10:00P
ALL WAKE 6:00A
ALL LEAVE 8:00A
ALL RETRN 4:30P
ALL SLEEP 10:00P
COPY TO ALL DAYS
COPY WAKE
COPY LEAVE
COPY RETRN
COPY SLEEP
MODE: AUTO
EDIT ALL DAYS
EDIT DAILY
PROGRAM SETTINGS
EDIT ALL DAYS
EDIT DAILY
LAST DATA RESET: 2000 JAN 01
BOILER FIRE ACTIV: 0H
BOILER PUMP ACTIV: 0H
DHW PUMP ACTIV: 0H
AUX PUMP ACTIV: 0H
SEC PUMP ACTIV: 0H
INJ PUMP ACTIV: 0H
AUX OUT ACTIV: 0H
MIX VLV. OPEN CYCLE: 0
MIX VLV. CLOSE CYCLE: 0
ZONE A-1
ACTIV: 0H
STATISTICS
3
4
5
1
THE
SYMBOLS INDICATE ADDITIONAL SELECTIONS ARE POSSIBLE.
THE FACTORY DEFAULT VALUES ARE SHOWN.
TEMPERATURE VALUES ARE SHOWN IN DEGREES FAHRENHEIT,
WHICH IS THE FACTORY DEFAULT TEMPERATURE UNIT.
EITHER HEAT OR COOL DISPLAYS DEPENDING ON THE SYSTEM’S STATUS.
FACTORY DEFAULT TIMES FOR MON THROUGH FRI.
FACTORY DEFAULT TIMES FOR SAT AND SUN.
2
3
4
5
EDIT ALL ZONES
EDIT SINGLE ZONE
ARE YOU SURE?
NO YES