Summary of Audible/Visual Notifications
(Continued)
Alpha Display Keypads
SOUND
CAUSE
DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
FIRE ALARM or CO ALARM (CO:
keypad/detector only; not external
sounder)
FIRE
or
ALARM
(for CO) is displayed; descriptor
of zone in alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be
displayed.
LOUD,
CONTINUOUS*
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM.
ALARM
is displayed. If programmed, descriptor
of zone in alarm is also displayed
ONE SHORT
BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM.
b. SYSTEM ARMING ATTEMPT WITH
AN OPEN ZONE.
c. BYPASS VERIFY.
a.
DISARMED/READY TO ARM
is displayed.
b. Number and descriptor of open protection zone
is displayed.
c. Numbers and descriptors of the bypassed zones
are displayed (One beep occurs for each zone
displayed). Then, the following displays:
DISARMED BYPASS /Ready to Arm.
ONE SHORT
BEEP
(about every 30
seconds)
Keypad only
a. SYSTEM IS IN TEST MODE.
b, LOW BATTERY AT A
TRANSMITTER.
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
a. Opened Zone identifications will appear.
b.
LO BAT
displayed with description of
transmitter.
c. No special display.
TWO
SHORT
BEEPS
Keypad only
ARM AWAY or MAXIMUM.
ARMED AWAY or MAXIMUM
displayed. Red
ARMED indicator lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY, NIGHT-STAY, OR
INSTANT.
b. ZONE OPENED WHILE
SYSTEM IS DISARMED.
a.
ARMED STAY
or
ARMED INSTANT
displayed.
Red ARMED indicator lit.
b.
CHIME
displayed, descriptor of open protection
zone will be displayed if the [
] key is pressed.
RAPID BEEPING
Keypad only
a. TROUBLE.
b. MEMORY OF ALARM.
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE FAIL.
e. LAST 10 SEC of EXIT DELAY
a.
CHECK
displayed. Descriptor of troubled
protection zone is displayed.
b.
FIRE
or
ALARM
is displayed; descriptor of
zone in alarm is displayed.
c.
SYSTEM LO BAT
displayed.
d.
BELL FAILURE
is displayed.
e. No special display.
SLOW BEEPING
Keypad only
a. EXIT DELAY WARNING (if
programmed).
b. ENTRY DELAY WARNING.
a.
ARMED AWAY or MAXIMUM
is displayed
along with
You May Exit Now.
b
. DISARM SYSTEM OR ALARM WILL OCCUR
is
displayed.
Exceeding the delay time
without disarming causes an alarm.
* If a bell is used as external sounder, fire alarm is
pulsed ring;
burglary/audible emergency is
steady ring
.