background image

Summary of Contents for WSP100

Page 1: ...Owner s Manual SUBMERSIBLE PUMP WSP50 lWSPlOO I I I I I I I I I I I I I I I I I I I I I I i i i i i i i i i i i i i i i i i i i i i I ...

Page 2: ......

Page 3: ...use and maintenance of your submersible sewage pump Follow the advice given to obtain optimum performance and correct opera tion of the pump For any other information you may require please contact the nearest appointed distributor IT IS STRICTLY FORBIDDEN TO REPRODUCE THE ILLUSTRATIONS AND THE TEXT EVEN IN PART 1 MANUFACTURER AND MACHINE IDENTIFICATION DATA 1 1 Manufacturer data I 2 Pump data 2 I...

Page 4: ...ction 12 2 Adjusting and registering 13 USE AND STARTUP 73 1 Automatic Pumps 13 2 Manual Pumps 14 MAINTENANCE AND REPAIRS 14 1 Troubleshooting 15 TECHNICAL DOCUMENTS SUPPLIED 15 1 Diagram for installation with minimum functional spaces fig I 15 2 Wiring diagram for WSP50AA WSPI OOAA 15 3 Wiring diagram for WSPSOAM WSPI OOAM 15 4 Diagram for cleaning the pump impeller fig 4 16 Warranty Information ...

Page 5: ...enance operations installations or shifting of the pump with the electric system live may cause severe or fatal injury During operation avoid moving or shifting the pump Before using the pump always check that the cable and all the electric devices are in working condition Never start the pump by inserting the plug in the socket and or switching on the switch with bare feet with your feet in the w...

Page 6: ...life and constant performance if used according to the indications given in chapter 8 and chapter 74 7 1 PUMP TECHNICAL DATA Max fluid temperature Max dimension suspended solids Max immersion depth Length of power cable Type of impeller Type of seal on the shaft Type of bearing Delivery diameter Impeller material Pump structure material Motor structure material Seal cover material Intake side cove...

Page 7: ...ps may be used for handling dirty or semi dirty water or water with suspended bodies with a diameter no greater than 50 mm for draining garages cellars basements swimming pools basins tanks fountains drains cesspools sewage collection drains from cesspools for draining excavations flowing irrigation from ditches rainwater tanks or streams The pump may be used for continuous duty only if totally su...

Page 8: ...OR DRAG n 4 THE PUMP To handle or disconnect the pump you must remove the plug from the power socket and or turn off the switch if provided roll up and hold the electric power cable in your hand lift the pump and the delivery pipe with the handle provided or with a cable fixed to the handle If the pump is set for fixed applications perform the following operations before handling it remove the plu...

Page 9: ...ION FOR TEMPORARY USE a The pump must be placed on a level surface b When positioning the pump observe the minimum required distances fig 1 from walls from the sides of the drain or other location so as to allow functioning c It is recommended to use G2 flexible pipes with couplings of the same size if required d It is recommended to fit a no return valve on the delivery pipe The pump has no separ...

Page 10: ... to the mini mum and maximum water level fig 1 13 1 AUTOMATIC PUMPS Insert the plug and or turn on the switch the pump starts operating once the pump has taken in water up to the minimum level fig 1 regulated by the float it will cut out automatically 13 2 MANUAL PUMPS Insert the plug and or turn on the switch the pump starts operating once the pump has taken in water up to the minimum level fig 1...

Page 11: ...AUSE No electric power Plug not inserted Float blocked Impeller blocked Thermal protection has tripped Faulty motor or capacitor Hole in the intake cover is blocked No return valve blocked TYPE OF FAULT REMEDY Check the contactor on the electric line Check power connection to the line Check that the float reaches ON level Check cause of blockage ch 14 This resets automatically Contact the nearest ...

Page 12: ...of the thermal protection CAUSE REMEDY Impeller blocked by foreign bodies Remove the foreign bodies ch 74 Be certain to disconnect power Liquid temperature too high The temperature exceeds the technical limits of the pump Internal defect Contact the nearest distributor 10 ...

Page 13: ...15 1 DIAGRAM FOR INSTALLATION WITH MINIMUM FUNCTIONAL SPACES fig 1 11 ...

Page 14: ...15 2 WIRING DIAGRAM WSP50AA AND WSPIOOAA fig 2 15 3 WIRING DIAGRAM FOR WSP50AM AND WSPlOOAM fig 3 1 115v 1 Bmm 2 Q I Main I Auxl I 12 ...

Page 15: ...15 4 DIAGRAM FOR PUMP IMPELLER COVER DISASSEMBLY fig 4 13 ...

Page 16: ...made by the dealership s management con tact the Honda Power Equipment Customer Relations Office You can write to American Honda Motor Company Power Equipment Division Customer Relations Office 4475 River Green Parkway Duluth GA 30096 2565 Or telephone 770 497 6400 weekdays 8 30 a m 5 00 p m EST When you call or write please provide us the following information l Model and serial number l Name of ...

Page 17: ...his way If you are dissatisfied with the decision made by the dealership s management contact the Honda Power Equipment Customer Relations Office You can write American Honda Motor Co Inc Power Equipment Division Customer Relations Office 4900 Marconi Drive Alpharetta GA 30005 8847 Or telephone 770 497 6400 M F 8 30 am 7 00 pm EST When you write or call please provide the following information Mod...

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...III Ill 11 11 I I I 11 l HONDA 00X31 WSP 8000 I I I I Recycled Paper I I I PRINTED IN U S A I I I I I ...

Reviews: