ELECTRIC STARTER
21-15
GROUND LINE
Remove the maintenance lid (page 3-4).
Turn the ignition switch to OFF.
Release the connector cover and disconnect the
starter relay 4P (Red) connector.
Check for continuity between the wire harness side
connector terminal and ground.
There should be continuity when the sidestand
retracted.
CONTINUITY INSPECTION
Remove the maintenance lid (page 3-4).
Turn the ignition switch to OFF.
Disconnect the negative (–) cable from the starter
relay.
Disconnect the starter relay 4P (Red) connector.
Remove the battery (+) cable and starter motor
cable from the starter relay.
Connect the fully charged 12 V battery positive (+)
terminal to the terminal "A" and negative (–) termi-
nal to the terminal "B" of the starter relay.
Connect the ohmmeter probes to the starter relay
4P connector terminal "C" and "D".
There should be continuity between the cable termi-
nals while the battery is connected, and no continu-
ity when the battery is disconnected.
CONNECTION: White/Green – Ground
W/G
4P (Red) CONNECTOR
Ground (–)
TERMINAL "D"
TERMINAL "B" (–)
TERMINAL "C"
TERMINAL "A" (+)
Summary of Contents for SH300I 2006
Page 54: ...MEMO...
Page 55: ...2 1 2 2 TECHNICAL FEATURES HEATER LESS O2 SENSOR 2 2 UNIT SWING ENGINE LAYOUT 2 3...
Page 58: ...MEMO...
Page 216: ...MEMO...
Page 242: ...CYLINDER PISTON 10 2 CYLINDER PISTON COMPONENT LOCATION...
Page 250: ...MEMO...
Page 270: ...MEMO...
Page 296: ...MEMO...
Page 314: ...MEMO...
Page 394: ...MEMO...
Page 422: ...MEMO...
Page 440: ...MEMO...
Page 456: ...MEMO...
Page 484: ...MEMO...
Page 499: ...24 1 24 24 WIRING DIAGRAMS STD type 24 3 ABS type 24 4...
Page 509: ...MEMO...